Page 32
ENGLISH
Jandy
®
Commercial Salt Chlorinator | Installation & Operation Manual
Section 7. Troubleshooting
NOTE:
Turn off power to unit prior to attempting service or repair.
Problem
Corrective Action
The production indicator always
shows "0" at any selected
production level
- Check the electrodes
- Check the output connections between power supply and the
electrolysis cell
- Check the salt concentration
The power supply doesn’t switch on
- Check the input connections are properly connected to the mains
- Check the fuse status located at the bottom of the device
The chlorine level into the water is
very low
- Check the chlorine measurement on the nozzles
- Check the chemical parameters into the water (pH, combined chlorine,
isocyanuric acid) are correct
- Increase filtration time
- Add chlorine stabilizer (isocyanuric acid) until reach 50-75 ppm
If issues persist, contact Jandy Technical Support at 1.800.822.7933