Commercial Salt Chlorinator | Installation & Operation Manual
ENGLISH
3.8 Pool Cover Control
The system has a dry contact input to adapt system
chlorine production in case the pool cover is
deployed. When the contact connected to this input
is closed (automatic cover deployed), the system
reduces its production rate to 10% of its normal
value (20% LED will light up).
1. Auxiliary contact normally open
2. Automatic cover opened
3. Automatic cover deployed
Figure 11. Pool Cover Control Contacts
Figure 12. Pool Cover Control Wiring
3.8.1 Enabling / Disabling Cover Control
• Decrease the production rate to 0% with the
down “V” button. “Stop” indicator will appear in
the HMI.
• Keep “V” button pressed for 10 seconds.
• Select control logics (ON/OFF) pressing the “^”
button.
ON / OFF cover
Enabled = cover on
Disabled = cover off