Jandy

®

 Pro Series FHPM Pump   

|

   Installation & Operation Manual

3. 

Align the pins in the four (4) spacers with the 

holes in the base and snap the spacers into 

place, as shown in Figure 5.

3.1.4  Pipe Sizing
3.1.4.1 

Suction Pipe

When the pump is located up to 50 feet from the pool, 

the recommended Schedule 40 

minimum pipe size for 

the suction side of the pump is 1½" for 

.75 

HP and 2" 

for 1 to 2 HP. For 2

.5

 HP pumps, the recommended pipe 

size is 2½". 

3.1.4.2 

Discharge Pipe

When the pump is located up to 50 feet from the pool, 

the recommended Schedule 40 minimum pipe size for 

the discharge side of the pump is 1½" for 

.75

 HP and 2" 

for 1

 to 2 HP. For 2.5 HP pumps, the recommended pipe 

size is 2½". 

NOTE

  All pipe sizes (Schedule 40) are able to withstand the 

pressures the pump will deliver, but not necessarily 

the flow. If the pipe is too small for the pump, or if 

the pump is elevated above water, the maximum 

gallons per minute (GPM) may not be delivered. If 

this happens, the pump will develop an air pocket 

(cavitation) that will make noise, and the life of the 

pump may be shortened.

3.1.4.3 

Installation Recommendations

1. 

If the pump is located below water level, 

isolation valves 

must

 

be installed on both sides 

of the pump to prevent the back flow of pool 

water during any routine or required servicing. 

2. 

To help prevent difficulty in priming, install 

the suction pipe without high points, which 

can trap air. (High points are inverted ‘U’s 

above the inlet of a pump. In plumbing, they 

are commonly referred to as airlocks.) For 

installations of equipment up to 100 feet from 

the water, refer to the pipe sizing chart in Table 

2. For installations of equipment more than 100 

feet from the water, the recommended pipe size 

must be increased to the next size.

Table 2. 

Pipe Sizing Chart for Schedule 40 PVC

Pipe 

Size

Maximum Flow 

Suction

(6 feet per second)

Maximum Flow 

Discharge

(8 feet per second)

1½"

37 GPM (140 LPM)

50 GPM (189 LPM)

2"

62 GPM (235 LPM)

85 GPM (322 LPM)

2½"

88 GPM (333 LPM) 120 GPM (454 LPM)

3. 

FHP Pumps come equipped with unions on 

both the suction and discharge ports. This 

feature simplifies installation and service, and 

it eliminates the possibility of leaks at threaded 

adapters.

4. 

The FHP Pump must be connected to at least 

two (2) main drains (suction outlets) for each 

pool pump suction line. Each drain (suction 

outlet) assembly must be provided with covers 

and must be listed or certified to the latest 

published version of ANSI

®

/ASME

®

 A112.19.8

or its successor standard, ANSI/APSP-16

. The 

suction outlets of the main drains must be at 

least 3 feet apart or at different planes. The 

suction  outlets can be a drain and skimmer, 

two (2) drains, two (2) skimmers, or a skimmer 

with an equalizer line installed. For additional 

details and guidelines, refer to ANSI/APSP 7, 

the standard for 

Suction Entrapment Avoidance 

in Swimming Pools, Wading Pools, Spas, Hot 

Tubs, and Catch Basins

. Check the local codes 

for proper installation requirements. Applicable 

local codes will take precedence over other 

codes.

NOTE

  To prevent entrapment, the system must be built so 

that it cannot operate with the pump drawing water 

from only one (1) main drain. At least two (2) main 

drains 

must 

be connected to the pump when it is in 

operation. However, if two (2) main drains run into 

a single suction line, the single suction line may be 

equipped with a valve that will shut off both main 

drains from the pump.

5. 

The piping must be well supported and not 

forced together in places where constant stress 

will be experienced.

6. 

Always use properly sized valves. Jandy Pro 

Series Diverter Valves and Ball Valves typically 

have the best flow capabilities.

7. 

Use the fewest fittings possible. Every 

additional fitting has the effect of moving the 

equipment farther away from the water. 

NOTE

  If more than 10 suction fittings are needed, the pipe 

size must be increased. 

8. 

Every new installation must be pressure tested 

according to local codes. See 

Section 3.3, 

Pressure  Testing.

3.2  Electrical Installation

3.2.1  Voltage Checks

The correct voltage, as specified on the pump data plate, 

is necessary for proper performance and long motor life. 

The incorrect voltage will decrease the pump’s ability 

to perform and can cause overheating, reduce the motor 

life, and result in higher electric bills.
It is the responsibility of the electrical installer to 

provide data plate operating voltage to the pump by 

ensuring proper circuit sizes and wire sizes for the 

specific application.

Summary of Contents for FHPM10

Page 1: ...this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death...

Page 2: ...tion Guidelines 5 Section 2 General Description 6 2 1 Introduction 6 2 2 Description 6 Section 3 Installation 6 3 1 Plumbing 6 3 2 Electrical Installation 9 3 3 Pressure Testing 11 Section 4 Operation...

Page 3: ...e pump without the test button being pushed a ground current is flowing indicating the possibility of electrical shock Do not use the pump Disconnect the pump and have the problem corrected by a quali...

Page 4: ...LLOWING SAFETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing...

Page 5: ...ain See Figure 1 More than one 1 pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction outlet assembly...

Page 6: ...e chosen for their strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which for...

Page 7: ...he pump needs to be protected from the rain and sun 6 Proper ventilation is required for the pump to operate normally All motors generate heat that must be removed by providing proper ventilation 7 Pr...

Page 8: ...o and WhisperFlo are registered trademarks of Pentair Water Pool and Spa Inc Pump Height Suction Side Height No Base Required Hayward Super Pump Pentair SuperFlo Sta Rite SuperMax Small Base Hayward S...

Page 9: ...nd it eliminates the possibility of leaks at threaded adapters 4 The FHP Pump must be connected to at least two 2 main drains suction outlets for each pool pump suction line Each drain suction outlet...

Page 10: ...n Sec 3 2 3 and in accordance with the requirements of the National Electrical Code NEC or in Canada the Canadian Electrical Code CEC the pump motor must be bonded to all metal parts of the swimming p...

Page 11: ...surized water in the system 4 Carefully observe the system for leaks and or pressure decay Section 4 Operation 4 1 Start up CAUTION Never run the pump without water Running the pump dry for any length...

Page 12: ...rned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to the pump Once all the air has...

Page 13: ...hould create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten There is no air in the system but the pressure is still low It is p...

Page 14: ...0 2 R0479702 4 Diffuser FHP Diffuser w O ring Hardware Backplate O ring 1 5 1 5 2 2 0 2 0 2 2 5 R0479701 5 Mechanical Seal Carbon and Ceramic 1 Set All R0479400 6 Pump Body FHP Body and Backplate O r...

Page 15: ...120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 FloPro FHPM 1 5 HP 3450 RPM FloPro FHPM 1 0 HP 3450 RPM FloPro FHPM 75 HP 3450 RPM FloPro FHPM 2 0 HP 1725 RPM FloPro FHP...

Page 16: ...acers Certified to NSF ANSI Standard 50 CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 NO 108 7 4 Physical and Operational Specifications 7 4 1 Specifications Table 4 FHPM Pump Specifications Mode...

Reviews: