background image

Page 2 

ENGLISH

  

 

Jandy

®

 Pro Series FHPM Pump   

|

   Installation & Operation Manual

Table of Contents

EQUIPMENT INFORMATION RECORD

DATE OF INSTALLATION

INSTALLER INFORMATION

INITIAL PRESSURE GAUGE READING (WITH CLEAR FILTER)

PUMP MODEL

HORSEPOWER

NOTES:

Section 1. Important Safety Instructions  ......... 3

1.1  Safety Instructions .............................................. 3
1.2  Pool Pump Suction Entrapment Prevention 

Guidelines .......................................................... 5

Section 2.  General Description ....................... 6

2.1 Introduction ......................................................... 6
2.2 Description ......................................................... 6

Section 3.  Installation ....................................... 6

3.1 Plumbing ............................................................ 6
3.2  Electrical Installation ........................................... 9
3.3  Pressure Testing ................................................11

Section 4.  Operation ........................................11

4.1 Start-up ..............................................................11

Section 5.  Service and Maintenance ..............11

5.1  Routine Maintenance ........................................11
5.2  Winterizing the Pump ....................................... 12

Section 6.  Troubleshooting ........................... 12

6.1 Troubleshooting ................................................ 13

Section 7.  Product Specifications and 

 

Technical Data .............................. 14

7.1  Replacement Parts List .................................... 14
7.2  FHP Exploded View .......................................... 15
7.3  Performance Curves ........................................ 15

7.4  Physical and Operational Specifications

 .......... 16

Summary of Contents for FHPM10

Page 1: ...this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death...

Page 2: ...tion Guidelines 5 Section 2 General Description 6 2 1 Introduction 6 2 2 Description 6 Section 3 Installation 6 3 1 Plumbing 6 3 2 Electrical Installation 9 3 3 Pressure Testing 11 Section 4 Operation...

Page 3: ...e pump without the test button being pushed a ground current is flowing indicating the possibility of electrical shock Do not use the pump Disconnect the pump and have the problem corrected by a quali...

Page 4: ...LLOWING SAFETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing...

Page 5: ...ain See Figure 1 More than one 1 pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction outlet assembly...

Page 6: ...e chosen for their strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which for...

Page 7: ...he pump needs to be protected from the rain and sun 6 Proper ventilation is required for the pump to operate normally All motors generate heat that must be removed by providing proper ventilation 7 Pr...

Page 8: ...o and WhisperFlo are registered trademarks of Pentair Water Pool and Spa Inc Pump Height Suction Side Height No Base Required Hayward Super Pump Pentair SuperFlo Sta Rite SuperMax Small Base Hayward S...

Page 9: ...nd it eliminates the possibility of leaks at threaded adapters 4 The FHP Pump must be connected to at least two 2 main drains suction outlets for each pool pump suction line Each drain suction outlet...

Page 10: ...n Sec 3 2 3 and in accordance with the requirements of the National Electrical Code NEC or in Canada the Canadian Electrical Code CEC the pump motor must be bonded to all metal parts of the swimming p...

Page 11: ...surized water in the system 4 Carefully observe the system for leaks and or pressure decay Section 4 Operation 4 1 Start up CAUTION Never run the pump without water Running the pump dry for any length...

Page 12: ...rned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to the pump Once all the air has...

Page 13: ...hould create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten There is no air in the system but the pressure is still low It is p...

Page 14: ...0 2 R0479702 4 Diffuser FHP Diffuser w O ring Hardware Backplate O ring 1 5 1 5 2 2 0 2 0 2 2 5 R0479701 5 Mechanical Seal Carbon and Ceramic 1 Set All R0479400 6 Pump Body FHP Body and Backplate O r...

Page 15: ...120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 FloPro FHPM 1 5 HP 3450 RPM FloPro FHPM 1 0 HP 3450 RPM FloPro FHPM 75 HP 3450 RPM FloPro FHPM 2 0 HP 1725 RPM FloPro FHP...

Page 16: ...acers Certified to NSF ANSI Standard 50 CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 NO 108 7 4 Physical and Operational Specifications 7 4 1 Specifications Table 4 FHPM Pump Specifications Mode...

Reviews: