background image

Page 7 

ENGLISH

  

 

Jandy

®

 Pro Series FHPM Pump   

|

   Installation & Operation Manual

Some Safety Vacuum Release System (SVRS) 

devices are not compatible with installation of check 

valves. If the pool has an SVRS device, be sure to 

confirm that it will continue to safely operate when 

any check valves are installed.

 WARNING

3. 

Install the pump such that any disconnecting 

means and/or junction boxes for power 

connection are withing sight of the pump and at 

least five (5) feet horizontally from the edge of 

the pool and/or spa. Choose a location that will 

minimize turns in the piping. 

NOTE

  In Canada, the minimum distance maintained from 

the edge of the pool and/or spa as noted above must 

be 3 meters (10 feet), as required by the Canadian 

Electrical Code (CEC, CSA C22.1).

4. 

The pump must be placed on a solid foundation 

that will not vibrate. To further reduce the 

possibility of vibration noise, bolt the pump to 

the foundation, or place it on a rubber mat.

NOTE

  Zodiac Pool Systems, Inc. recommends bolting the 

pump directly to the foundation.

5. 

The pump foundation must have adequate 

drainage to prevent the motor from getting wet. 

Protect the pump from the rain and sun.

6. 

Proper ventilation is required for the pump 

to operate normally. All motors generate heat 

that must be removed by providing proper 

ventilation.

7. 

Provide access for future service by leaving a 

clear area around the pump. Allow plenty of 

space above the pump to remove the lid and 

basket for cleaning.

8. 

If the equipment is under cover, provide 

adequate lighting.

3.1.3  Replacement of Existing Pump

Jandy Pro Series FHP pumps can easily replace several 

other pumps: the Hayward

®

 Super Pump

®

, Hayward 

Super II, Pentair

®

 SuperFlo

®

, Pentair

®

 WhisperFlo

®

Jandy Pro Series

®

, PlusHP (PHP), Jandy Pro Series 

MaxHP (MHP), Sta-Rite

®

 Dura-Glas

®

, Sta-Rite Dura-

Glas II, Sta-Rite Dyna-Glas

®

, Sta-Rite Max-E-Glas

®

Sta-Rite Max-E-Pro

®

, and Sta-Rite SuperMax

®

To replace the Pentair WhisperFlo, Jandy Pro Series 

PHP, or Jandy Pro Series MHP, use the FHP’s adjustable 

base. The FHP base (and its spacers) increase the total 

height of the pump and the height of the suction side of 

the pump. See Table 1 and Figure 3.

Table 1. 

FHP Dimensions

Base Configuration

Suction Side 

Height

Pump Height

1.  Pump without  

     Base

¾

" (197 mm)

12 

¾

" (44 mm)

2.  Pump with Base

9" (229 mm)

14" (356 mm)

3.  Pump with Base 

     and Spacers

¼

" (235 mm)

14 

¼

" (362 mm)

4.  Pump with Small   

     + Large Base

10 

 (276 mm)

15 

 (403 mm)

3.1.3.1 

Install Spacers into Small Base

1. 

Using a hand cutter tool, cut the plastic bars 

connecting the top and bottom sets of spacers, 

as shown in Figure 4.

2. 

Push the two (2) top spacers and two (2) bottom 

spacers out of the base.

3. 

Align the pins in the four (4) spacers with the 

holes in the base and snap the spacers into 

place, as shown in Figure 5.

AQUAPURE

MANUAL BY-PASS DETAIL
MANUAL BY-PASS IS USED
WHEN FILTRATION RATE
EXCEEDS 125 GPM

Figure 2.  Typical Piping Installation

Summary of Contents for FHPM

Page 1: ... this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or operation will void the warranty Improper installation and or operation can create unwanted electrical hazard which can cause serious injury property damage or death ATTE...

Page 2: ...ntion Guidelines 5 Section 2 General Description 6 2 1 Introduction 6 2 2 Description 6 Section 3 Installation 6 3 1 Plumbing 6 3 2 Electrical Installation 9 3 3 Pressure Testing 11 Section 4 Operation 11 4 1 Start up 11 Section 5 Service and Maintenance 11 5 1 Routine Maintenance 11 5 2 Winterizing the Pump 12 Section 6 Troubleshooting 12 6 1 Troubleshooting 13 Section 7 Product Specifications an...

Page 3: ...without the test button being pushed a ground current is flowing indicating the possibility of electrical shock Do not use the pump Disconnect the pump and have the problem corrected by a qualified service representative before using Due to the potential risk of fire electric shock or injuries to persons Jandy Pro Series Pumps must be installed in accordance with the National Electrical Code NEC a...

Page 4: ... SAFETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 100 F 38 C Limit test to 24 hours After test visually check system to be sure it is ready for operation NOTICE These ...

Page 5: ... Figure 1 More than one 1 pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction outlet assembly and its cover for any suction outlet must not exceed the suction fitting assembly and it s cover s maximum design flow rate The suction outlet drain assembly and its cover must comply with the latest version...

Page 6: ...aterials These materials were chosen for their strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow through the pump The water flows through the pump inlet and then into the filter basket The basket assembly pre strains traps large particles The water th...

Page 7: ...ture service by leaving a clear area around the pump Allow plenty of space above the pump to remove the lid and basket for cleaning 8 If the equipment is under cover provide adequate lighting 3 1 3 Replacement of Existing Pump Jandy Pro Series FHP pumps can easily replace several other pumps the Hayward Super Pump Hayward Super II Pentair SuperFlo Pentair WhisperFlo Jandy Pro Series PlusHP PHP Jan...

Page 8: ...lo and WhisperFlo are registered trademarks of Pentair Water Pool and Spa Inc Pump Height Suction Side Height No Base Required Hayward Super Pump Pentair SuperFlo Sta Rite SuperMax Small Base Hayward Super II Jandy PlusHP Jandy Max HP Small Base Large Base Sta Rite Max E Pro Sta Rite Dura Glas Sta Rite Dura Glas II Sta Rite Max E Glas Small Base with Spacers Pentair WhisperFlo Sta Rite Dyna Glas F...

Page 9: ...must be listed or certified to the latest published version of ANSI ASME A112 19 8 or its successor standard ANSI APSP 16 The suction outlets of the main drains must be at least 3 feet apart or at different planes The suction outlets can be a drain and skimmer two 2 drains two 2 skimmers or a skimmer with an equalizer line installed For additional details and guidelines refer to ANSI APSP 7 the st...

Page 10: ...st be used Bond the motor using the external bonding lug provided on the motor frame To avoid the risk of property damage severe personal injury and or death always disconnect the power source before working on a motor or its connected load WARNING To avoid the risk of property damage severe personal injury and or death make sure that the control switch or time clock is installed in an accessible ...

Page 11: ...d clamps are secure according to the manufacturer s recommendations To avoid risk of property damage severe personal injury or death verify that all power is turned off before starting this procedure WARNING 1 Release all pressure from the system and open the filter pressure release valve 2 Take one of the following actions If the pump is located below the water level of the pool open the filter p...

Page 12: ...the filter pressure release valve 5 2 Winterizing the Pump The pump must be protected when freezing temperatures are expected Allowing the pump to freeze will cause severe damage and void the warranty CAUTION Do not use antifreeze solutions in the pool spa or hot tub systems Antifreeze is highly toxic and may damage the circulation system The only exception to this is Propylene Glycol For more inf...

Page 13: ...should create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten There is no air in the system but the pressure is still low It is possible that debris is caught in the pump impeller The pump impeller moves the water and the vanes in the impeller can become blocked with debris 1 Turn off the pump Switch off the circuit breaker to...

Page 14: ...1 0 2 R0479702 4 Diffuser FHP Diffuser w O ring Hardware Backplate O ring 1 5 1 5 2 2 0 2 0 2 2 5 R0479701 5 Mechanical Seal Carbon and Ceramic 1 Set All R0479400 6 Pump Body FHP Body and Backplate O ring All R0479800 7 Motor Mounting Foot FHP All R0479900 8 Lid w Locking Ring FHP Lid w Locking Ring Lid O ring All R0480000 9 Pump Debris Filter Basket FHP All R0480100 10 Drain Plug w O ring Set of ...

Page 15: ...0 120 130 140 150 160 170 180 190 200 210 220 230 240 250 0 5 10 15 20 25 30 35 FloPro FHPM 1 5 HP 3450 RPM FloPro FHPM 1 0 HP 3450 RPM FloPro FHPM 75 HP 3450 RPM FloPro FHPM 2 0 HP 1725 RPM FloPro FHPM 1 5 HP 1725 RPM FloPro FHPM 1 0 HP 1725 RPM FloPro FHPM 2 0 HP 3450 RPM FloPro FHPM 2 5 HP 3450 RPM Total Dynamic Head Feet of Water Pounds Per Square Inch PSI Jandy FloPro Series Pumps Max Rated F...

Page 16: ...ons without Base or Spacers CONFORMS TO UL 1081 CERTIFIED TO CSA C22 2 NO 108 7 4 Physical and Operational Specifications 7 4 1 Specifications Table 4 FHPM Pump Specifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A FHPM 75 0 75 230 115 5 4 10 8 1 2 40 6 25 3 16 FHPM 1 0 1 00 230 115 7 1 14 2 2 2 41 2 25 3 16 FHPM 1 5 1 50 230 115 8 0 16 2 2 42 6 25 FHPM 2 0 2 00 230 115 ...

Reviews: