Page 16
ENGLISH
Jandy
®
FHP Pumps | Installation & Operation Manual
7.4 Physical and Operational Specifications
7.4.1 Specifications
Table 4. FHPM Pump Specifications
Model No.
THP
WEF
(Weighted
Energy Factor)
Voltage
Amps
Pipe Size
Carton Weight
Overall Length 'A'
FHPM.75
0.95
4.1/4.3
208-230/115 4.5-4.4/8.8
1½-2"
40.6
25 3/16"
FHPM1.0
1.14
3.6
208-230/115 5.4-5.2/10.3
2-2½"
41.2
25 3/16"
FHPM1.5
1.65
-
230/115
8.0/16
2-2½"
42.6
25 ½"
FHPM2.0
2.26
-
230/115
11.2/22.4
2-2½"
54.6
27 3/16"
FHPM2.5
2.60
-
230
11.5
2½-3"
48.6
26 3/16"
FHPM1.0-2
1.14
5.6
230
5.3/2.2
2½-3"
46.5
26 5/16"
FHPM1.5-2
1.65
-
230
7.2/3.0
2½-3"
48.0
26 9/16"
FHPM2.0-2
2.22
-
230
10.0/3.5
2½-3"
52.9
27 11/16"
7.4.2 Dimensions
Table 1 shows the height of the FHP pump in the four (4) mounting configurations listed below. Figure 3 shows
drawings of these four (4) configurations.
6 ¾"
10 ⅞"
NOTE:
See FHPM Pump
Specifications Table
for the value of 'A'.
Bolt Holes, Center to Center
Front Edge of Union, to Center of Bolt
NOTE:
When installing the
pump, leave a minimum
of two feet (2 ft) of
clearance above the
pump for removal of
the strainer basket.
7 ¾"
12 ¾"
10"
7 ¾"
'A'
11 ⅛"
Figure 6. FHP Pump Dimensions (without Base or Spacers)