23
OUTPUT FAULT is displayed
when there is a problem with the
power supply (service required)
On/Off
Output
Flow
S alt
R
ON
* OUTPUT FAULT *
Error Warning
• All settings are saved using the backup battery as well as EEPROM
memory in case the battery runs flat. The battery life is 500 hours. They
are NiMH batteries and are not replaceable
• When connected to a controller and SPA mode is selected at the
controller the output of the Ei will drop to 20% (minimum)
• When connected to a controller and BOOST is selected at the controller,
the output of the Ei will go to 100%
• The correct output current is 5 Amps +/- 5%. The output voltage depends
on the cell condition, salt level and water temperature. When running @
4000ppm Salt & 80° F with a new cell the Ei output voltage will be around
21-22VDC.
• If either or both fuses on the PCB are blown, replace the PCB.