Section 4. Operation
Figure 12. Controller Lights
Power Sensor Filling
Electronic
Water Fill
System
The next generation
in automated controls.
Patented
High Voltage Compartment
No user service parts inside
Model No. K-2000
High Water High Water
Sensor Pump
Power
Sensor
Filling
High
Water
Sensor
High
Water
Pump
II
olor
Lev
4.1 Controller Lights
The controller has five (5) LED lights. See Figure 12
and Table 2, LED Indicators.
The Power light turns green when power is on.
The Sensor light turns yellow when the water is not
touching the Fill Sensor.
The Fill light turns green when the valve is operational
and filling, and it turns red when the unit enters Lockout
Safety Mode.
The High Water Sensor light turns yellow when the
High Water Sensor is in the water.
The High Water Pump light turns green when the
vanishing edge pump is running.
LED
Function
Indicated
Color
Operating
Mode
Delay to Turn Function
ON
Delay to Turn Function
OFF
Power
Turn Power ON
Green
Power is
ON
None
None
Sensor
Detect Low Water in
Catch Basin
Yellow
Water is
Low
None
None
Filling
Fill Pool
Green
Fill Valve is
ON
20 Sec after Sensor
Light Turns ON
20 Sec after Sensor Light
Turns OFF
Fill Safety Lockout
Red
Fill Valve is
OFF
20, 40 or 60 Min
24 Hrs
High Water
Sensor
Detect High Water
in Catch Basin
Yellow
Water is
High
None
None
High Water
Pump
Pump Water from
Catch Basin to Pool Green
High Water
Pump is ON
20 Sec,
1, 2½ or 5 Min
20 Sec or 2½ Min
5, 10, 15 or 20 Min
25, 30, 35 or 40 Min
Stop Pumping Catch
Basin Water to Pool
Off
High Water
Pump is OFF
20 Sec or 2½ Min
5, 10, 15 or 20 Min
25, 30, 35 or 40 Min
Not Applicable
Table 2. LED Indicators