STEP 8: Check Normal Operating Sequence
1. Turn on the heater in Pool or Spa mode via the user interface.
2. Verify current water temperature reading on the user interface,
then configure the set point so it is higher than the current
temperature. This will prompt the ignition sequence.
3. Verify the blower starts (this signifies the ignition sequence has
begun).
4. Verify that the igniter powers up after a 15-second pre-purge.
5. Verify that the heater begins normal operation once flame is
sensed at the burner.
6. Turn off the heater via the user interface.
STEP 9: Affix Conversion Rating Plate to the Heater
WARNING
Failure to follow this STEP and all warning notices and instructions
may result in property damage, personal injury, or death. Improper
installation and/or operation can create carbon monoxide gas and flue
gases which can cause serious injury, property damage, or death.
1. Reinstall the brace bar and gasket retainer bracket.
2. Reinstall the heater rear panel and the gas valve shield.
3. Reinstall the heater top panel. Take care not to damage or abrade
any wiring.
4. Using a permanent marker, fill out the top section of the new fuel
type data rating plate sticker. BE SURE TO PRINT LEGIBLY.
• Date of Modification
• Company Name and Technician performing the conversion
• Company Address