background image

1

Press

 “”

 and enter Pre-heating setting mode, and the LCD flashes of “ON” 

, the “PREHEAT” icon

will flash

 , and then the circulation works on. Press

”again to

 turn off pre-heating. The LCD will show

“OFF” without flashing. 

2

) 、

Press“

minutes

and“

hours

 to adjust the time.

It will add 1 minute when pressing

  “

MIN

  each time and the minutes could be added continually.

The adjustment range is 0~59.

It will add 1 hour when pressing  

HOUR

  each time  and the hours could be added continually.  The

adjustment range is 

0-23.

After setting the heating pre-set timing, proceed to the next step.

3)

Press“

 to set the circulation times; it will show the minimum(10 minutes) on the LCD and this time

will not flash. It will add 10 minutes by pressing 

 each time.

 It will add 1 hour by pressing“

”each

time

The maximum working time is 19hours and 50 minutes.

 When you have completed this procedure continue

to the next setting.

4)

Press

 “

SET

VOL+

 again It will show “ SET” on the LCD panel. Press

 “

 button to change the setting

temperature. The range of temperature setting is: 

15~40

℃。

5)

When everything is set correctly, press the

 “

” to confirm,

 the system will quit the pre-heating setting

mode.

***Notice***

1

All setting of preheating must be in Power OFF mode, just turn on the spa

the

LCD will display “---”

2

Please note that it shows "on" or "off" on the LCD.  "on" means preheating is

turned  on  mode.  when the time  of  pre-heating  is  as  same as  current time, the
heater will start working. "off" means the heater won’t start to work an any time.

3

Circulation PUMP and HEATER without working while setting preheating.

6

Operation of 

preheating

When the preheating time is as same as the current time, the LCD screen shows “on” and the tub is also

filled   with   water.   The   heater   will   start   to   work.   The   heater,   circulation   pump   and   time   counting   work   at

simultaneity. The countdown time will be shown on the LCD screen, till the preset time is finished.

During the preheating, The preheating will be turned off automatically once the preset time is finished. 

7

Summary of Contents for SPA J-838

Page 1: ...HOT TUB Model SPA 565 OPERATING INSTRUCTION 1 ...

Page 2: ...lower On off or Switch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with blue letters only works on the condition of on off 2 ...

Page 3: ...circuit display 1 When you first start the spa the backlight will be dimmed and the LCD will show the current time and temperature If there is a problem with the circuit board the controller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and circulation cleaning function is off 2 Lock memory Mode optional function T...

Page 4: ... 5 Circulation cleaning off Fig 6 Circulation cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and then the circulation works on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1...

Page 5: ...g each time The maximum working time is 19hours and 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not work...

Page 6: ...res whether pre heating settings are set or not See following Fig 7 8 ON OFF Fig 7 Pre heat On 图 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Continual time of preheating 4 Preset temperature 5 Finished 6 ...

Page 7: ...Press SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 40 5 When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD...

Page 8: ...s the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turned off automatically once the preset time is finished or Pressing the key can stop directly 8 Operation to Power ON OFF Pressing the key from power off status to enter the power on status To pressing the in...

Page 9: ...ly will memorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 Ⅵ The volume can be changed by pressing key SET VOL and OPEN 11 Operation of Pump The Button operates pump 1 The Button PUMP2 operates pump 2 The button PUMP3 operates pump 3 When Circulation cleaning and heating including preheating turn on circulation pump will be working automatical...

Page 10: ...pa is on normal power supply IV Electric parameters 1 Performance index Rated voltage 220V 50Hz Maximum working current 60 A 220V 240V Voltage resistance 1250V 1 minute without penetration Isolative resistance 10MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x 1 water pump AC220V 2HP x 2 pump AC220v 1HP ...

Page 11: ...ipotential bonding is carried out WAR NING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technician qualified in hydrotherapy bath installation 4 lt s prohibited...

Page 12: ...e 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water not achieve the appointed level 2...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Reviews: