background image

2

With the setting above, the circulation pump will work automatically.

3

)、

If the temperature is set at 3

5℃,

 when the water temperature reaches or exceeds 3

6℃,

 the heater

will be turned off automatically and the circulation pump will stop after 5 seconds. When the water temperature
reaches or is lower than 3

4℃,

 the heater will start up again.

4

)、

In the case of an error the LCD shows ”E1”.  If this happens, the thermostatic heating system will

NOT be available, the heater doesn’t work.

15

Operating the Air Blower

Press

 controls the blower.

16

Fahrenheit & Celsius Temperature shift

In the status of

Power off

 pressing the key

 “

” can change the mode of 

Fahrenheit & Celsius degree.

 

17

When there is no water in the spa. All water pumps and heating system can not start up. However the

corresponding signals will flash on the LCD.

18

Prevent freezing function:

The heater & circulation pump will work automatically once the water temperature is below 

5℃,

 when the water

temperature is reach at  10 ,  heating will stop. This function is only available while the spa is on normal power

supply.

IV

Electric parameters

1

Performance index

Rated voltage

 220V/50Hz                        

Maximum working current

60 A/220

V-240V~

Voltage-resistance

1250V/1

 minute without penetration

     

Isolative resistance

:》

10MΩ

Water resistance grade

IPX5                             

Electric shock resistance

first grade

(2) Output loading index

Heater

 AC220V/3KW x 1                          Surf Water pump

 AC220V/3 HP x 1

water pump

 

 AC220V/2H

P x 2                     pump

AC220v/1HP x 1

Air pump

 AC220V/0.7kw x 1  

spa light

 AC12V/5W x 1                         Ozone

Ozone

 12

V

/15

W×1

water Radio

1) Frequency Range

 FM

 87.0~108.0MHz

        2) Maximum Output Power

 10W

3) Speaker

8Ωdamp proof speaker

5.Warning Information

a.

       

Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

b.

       

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

c.

       

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety.

d.

       

Children should be supervised to ensure that they do not play with the appliance.

10

Summary of Contents for SPA J-838

Page 1: ...HOT TUB Model SPA 565 OPERATING INSTRUCTION 1 ...

Page 2: ...lower On off or Switch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with blue letters only works on the condition of on off 2 ...

Page 3: ...circuit display 1 When you first start the spa the backlight will be dimmed and the LCD will show the current time and temperature If there is a problem with the circuit board the controller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and circulation cleaning function is off 2 Lock memory Mode optional function T...

Page 4: ... 5 Circulation cleaning off Fig 6 Circulation cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and then the circulation works on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1...

Page 5: ...g each time The maximum working time is 19hours and 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not work...

Page 6: ...res whether pre heating settings are set or not See following Fig 7 8 ON OFF Fig 7 Pre heat On 图 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Continual time of preheating 4 Preset temperature 5 Finished 6 ...

Page 7: ...Press SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 40 5 When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD...

Page 8: ...s the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turned off automatically once the preset time is finished or Pressing the key can stop directly 8 Operation to Power ON OFF Pressing the key from power off status to enter the power on status To pressing the in...

Page 9: ...ly will memorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 Ⅵ The volume can be changed by pressing key SET VOL and OPEN 11 Operation of Pump The Button operates pump 1 The Button PUMP2 operates pump 2 The button PUMP3 operates pump 3 When Circulation cleaning and heating including preheating turn on circulation pump will be working automatical...

Page 10: ...pa is on normal power supply IV Electric parameters 1 Performance index Rated voltage 220V 50Hz Maximum working current 60 A 220V 240V Voltage resistance 1250V 1 minute without penetration Isolative resistance 10MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x 1 water pump AC220V 2HP x 2 pump AC220v 1HP ...

Page 11: ...ipotential bonding is carried out WAR NING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technician qualified in hydrotherapy bath installation 4 lt s prohibited...

Page 12: ...e 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water not achieve the appointed level 2...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...