background image

DISINFECTING YOUR PEDICURE SPA

        

  

Note: 

Please be advised that it is responsibility of purchaser/user to adhere strictly to the following procedure.        

Any non-compliance will be considered negligence of the purchaser/user. 

        

           The Bureau of barbering and cosmetology requires that salons using whirlpool pedicure spas use the following disinfecting 
           Procedures to ensure proper cleaning and maintenance of the equipment, and to prevent bacterial infection. For your clients 
           safety, always use the regulations as a minimum standard for cleaning and disinfecting.

         

           Chair maintenance
                      Please see chair manual for Do and Don't
                       

          

         

 

At the end of the day:

                      1.  Remove the intake suction screen, All debris trapped behind the screen of each pedicure spa must be removed.
                           And the screen and the inlet shall be washed with soap or detergent and water

                      2.  Before replacing the screen, Totally immersed the screen into an EPA- registered disinfectant with bactericidal,
                           Fungicidal, and virucidal activity.

                      3. Finally, flush the whirlpool system with low-suding detergent and warm OR an EPA - registered cleanser for 
                          10 minutes. Rinse with clean fresh water and drain.

Note:

Cleaning or sanitizing is NOT disinfecting. According to the CDC and EPA, disinfecting occours only when there is a 
reduction of pathogenic microbes at 99.999%. Sanitizing is a only reduction of 99.9%. Cleaning of whirlpool pedicure spa 
requires surfactant and chelating detergents that are low foaming and have ability to remove body oils, organic oil 
additives, mineral oil, skin cell, nail clippings, etc.. that can accumulate both in the basin and the jets which may become 
fertile area for micro organism to grow.

Note:
The use of oil based products can build up in the whirlpool system causing clogging in the jet and build up onto the surface 
of the basin. Adherence to the above cleaning will minimize build up thus the manufacturer recommend not to use mineral
oil based product. 

Summary of Contents for Lenox GX

Page 1: ...X G WHIRLPOOL PEDICURE SPA Owner s Manual Copyright 2010 by J A USA Inc Printed in USA Pedicure Spa L E N O X Please read user s Manual thoroughly before using pedicure spa...

Page 2: ...n Specification Dimension Drainage Connection Installation Summary Maintenance Dura Jet Maintenance Magna Jet OPTIONAL Discharge Pump Chair Backrest attachment Remote Control Function Disinfecting Ped...

Page 3: ...250 pounds Health Warning Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use the pedicure spa at any time The technician should advise clients to consult thei...

Page 4: ...Back Rest Cover BackRest Padding Easy Access Up down Armrest Manicure Tray W Cup Holder Dual Functional Shower Sprayer Three Stage Adjustable Footrest Tampered Glass Bowl Drain Handle Non Slip Bumpon...

Page 5: ...SME American Society of Mechanical Engineers CSA Canadian Standard Association IAPMO International Association of Plumbing and Mechanical Officials UL Underwriters Laboratory 110V 60Hz 15Amp GFCI prot...

Page 6: ...Massage Chair Toepia GX Dedicated 15Amp Wall Outlet Require Pipe less whirlpool motor Discharge Pump Optional Massage System Hot Water Cold Water Drain Unit Optional Item 67L x 37W x 40H 285 lbs 20 25...

Page 7: ...Front View 39 3 4 14 3 4 55 1 4 15 3 8 16 1 4 31 3 4 4 6 3 4 Rear View 21 29 3 4 27 15 Wall GX L E N O X Dimension 7 3 4 24 3 3 5 10 14 16...

Page 8: ...Drain See detailed power drain pump 15 6 41 15 2 3 4 Rear View Basement Connection NOT recommended on floor drain Wall drain GX L E N O X 24 3 3 5 10 14 16 Hot and Cold Water Inlet 1 2 Drain 1 1 2 PVC...

Page 9: ...must be capable of supporting the occupied pedicure spa For the seat back to fully recline the pedicure spa base must be mounted as follow from the wall as shown below When chair slide all the way ba...

Page 10: ...safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons including the following Safety Instructions Cleaning Instruction 1 Ensure the unit is of...

Page 11: ...tream 2 Magnetic whirlpool jet cover can be remove for quick cleaning and sanitizing 3 Built In electronic sensor for pump control 4 AC Whirlpool motor long life 5 Very low power consumption 27W 6 Man...

Page 12: ...IRMLY TO BRING CLOSER TO THE ROUND MAGNETIC FILED AND DO NOT RELEASE THE MAGNETIC JET PREMATURELY OR THIS WILL CAUSE IMPACTS ON THE JET COVER AND THE ROUND MAGNETIC FIELD HOUSING SHORTENING THE LIFE E...

Page 13: ...7 It is very important that tip of the clear tub remain above the water Level with one loop as shown Please cut to fit 1 Flex hose to your size Installation Instruction X G L E N O X On Off Switch Fas...

Page 14: ...ain Shaft D C Motor Kneading Massage Roller Kneading Gear Massage Arm extension D C Motor Tapping Belt Up Down Limited Sensor Red Vibration Fuse Power Kneading Tapping Up Down Recliner Slider Receptac...

Page 15: ...wer portion of both side of the backrest there are pivots Fig 1 Align both pivots correctly so they rest perfectly onto the U pivot frame Fig 2 Once both pivots sit snugly on the U pivot frame align t...

Page 16: ...tion INCLINE RECLINE Press once the chair will move automatically Press twice to stop the movement KNEADING It has Strong medium weak 3 intensity adjustments and the setting intensity is at medium 5 1...

Page 17: ...ally immersed the screen into an EPA registered disinfectant with bactericidal Fungicidal and virucidal activity 3 Finally flush the whirlpool system with low suding detergent and warm OR an EPA regis...

Page 18: ...or are feeling ill Your body shows any cute symptoms You have heart disease You are pregnant or having a menstrual period Your doctor has ordered you to rest You have a back disorder resulting from an...

Page 19: ......

Page 20: ...eceipt from the original consumer purchaser and must accompany all warranty claims Implied warranties including that of merchantability or fittness for a particular purpose are expressly limited in du...

Page 21: ...NUFACTURER NEOPERL INC Waterbury CT DEVICE MODEL Dual Check Valve 1 2 x 2 NPT DEVICE SPECIFICATION TESTED AND CERTIFIED TO MEET NSF ASSI 61 Complies with ANSI ASME A112 18 3M A112 18 1M AND CSA B125 D...

Page 22: ...right or authority to bind J A USA INC to changes to this limited warranty Consequently J A USA INC is not responsible for such warranties or representations NO CONSEQUENTIAL INCIDENTAL CONTINGENT IND...

Page 23: ...uct Yes No Yes No Yes No Yes No Year s Year s Year s 4 What is the most important features in choosing Pedicure Spa Brand Design Function Service 1 Are you satisfy with Pedicure spa received Price Oth...

Reviews: