Install Mounting Track
Install mounting track onto the pipe with stainless steel strap. Fix it tightly.
Install Transducers
Apply couplant gel onto bottom of transducers and locate transducer into
onto PIPE
mounting track. Make transducers clamp-on pipe by tighten a clamp
screw.
Install Info
Auto Install
Xonic 100 uses its patented AR mode ultrasonic signal for flow
measurement. User simply select YES, then Xonic 100 start AR mode
automatic installation procedure. User can see how AR mode find best
signal.
센서고정용트랙
트랙고정용 스트랩
Space
센서의 설치거리
INSTALL INFO.
Pipe: CARBON STEEL
-OD: 0.00mm
INSTALL
-T: 0.00mm
1 . SENSOR TYPE
Liner: NONE
2 . SAMPLING CLK
-T: 0.00mm
3 . MOUNT TYPE
Sensor: B(B)
4 . SENSOR DISTANCE
-Clk: 20nS
5 . INSTALL INFO.
Mnt: CLAMP-ON V
6 . AUTO INSTALL
Space: 0.0mm
7 . ACTUAL ZERO
(E: 7.0mm)
INSTALL
1 . SENSOR TYPE
2 . SAMPLING CLK
3 . MOUNT TYPE
4 . SENSOR DISTANCE
5 . INSTALL INFO.
6 . AUTO INSTALL
1 . NO
7 . ACTUAL ZERO
2 . YES
AUTO INSTALL
Strap Kit