background image

 

 

 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 

 

TS-2030EN/TS-2076EN/ 

TS-1327EN Series 

Progressive Scan Cameras 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

Document Version: C 

Document P/N:10490 

Summary of Contents for TS-2030EN Series

Page 1: ...TS 2030EN TS 2076EN TS 1327EN Series Progressive Scan Cameras Document Version C Document P N 10490...

Page 2: ......

Page 3: ...0 A2 2003 Immunity EN55024 1998 A1 2001 A2 2003 All JAI Inc products bearing the CE mark have been declared to be in conformance with the applicable EEC Council Directives However certain factory inst...

Page 4: ...responsible for FCC compliance could void the user s authority to operate the equipment EN Camera Series Operation Manual JAI Inc 625 River Oaks Parkway San Jose CA 95134 Tel 408 383 0300 Tel 800 445...

Page 5: ...P Address Assignment 14 3 5 1 DHCP Client 15 3 6 Maintenance 16 3 6 1 Debug Counters 16 3 6 2 Firmware Upgrade 17 3 6 3 RS 232 PowerPC Debug Port 18 4 Uploading the Firmware 21 4 1 To Verify Version N...

Page 6: ...are Does Not Find Any Camera in the Network 41 7 5 Problem 5 EN Setup Software Found the Camera But the Video Image is too Dark or Just Black 41 7 6 Problem 6 TTL Trigger Ethernet Trigger Serial RS 48...

Page 7: ...D Sub Connector 25 Figure 13 Serial Communications Cable RS 232B 12 JAI Inc part number 310 132 19 26 Figure 14 12P 02S Interface Cable optional 27 Figure 15 Timing Chart 1 TS 2030EN 30 Figure 16 Timi...

Page 8: ...EN Camera Series viii List of Figures...

Page 9: ...e 4 10 100 BaseT Ethernet Pinout Configuration 26 Table 5 EN Exposure Times 34 Table 6 Factory Default Settings of the ADR Shutter Min and Max 34 Table 7 Gain Table BW EN Camera 35 Table 8 Gain Table...

Page 10: ...EN Camera Series x List of Tables...

Page 11: ...nstallation Manual 1 3 Key Functions of the EN Camera Sensitive high speed progressive scan CCD camera 1 format for the TS 2030EN and the TS 2076EN 2 3 format for the TS 1327EN 10 100 Mbit BaseT Ether...

Page 12: ...on ROI as used in the market for ITS Intelligent Transportation Systems The EN camera supports external event triggering dynamic light sensor and provides the best quality and sensitivity images for I...

Page 13: ...era It is very important that your PC NOT be assigned the same IP address as the camera If you need to change the IP address follow the instructions in Section 2 2 2 on page 4 2 2 2 Changing the IP Ad...

Page 14: ...ge the local IP address 5 Type the IP address you want to change 6 Type 0 to return to the main menu and then type 0 to start up the normal boot up 2 3 Installing the Required Software The EN setup so...

Page 15: ...t on your desktop or go to Start All Programs EN Setup EN Setup Start the EN Setup software Type the case sensitive user name Administrator and password Password You can create a new user and password...

Page 16: ...erated by an internal trigger mechanism inside the EN camera This internal trigger is independent of either FTP or message based TCP image Also during live image display Flash is disabled at nighttime...

Page 17: ...Tutorial 7 EN Camera Series Figure 5 Live Image Capturing Figure 6 Focus Bar Use the Focus Bar button to make precise adjustments to the lens focus...

Page 18: ...f Size image button is useful for situations in which two EN cameras together cover a single lane Using the Half Size image button to capture two images one on the left side of camera1 the other on th...

Page 19: ...N camera to take a single shot of video image as soon as it receives a valid TTL trigger Ethernet trigger or RS 485 serial trigger All trigger mode is continuous trigger sniffing mode Trigger sniffing...

Page 20: ...monitor the image properties of captured images whether it s Live Snap or Trigger Sniffing mode On the Video Window menu select Image Properties under View You can also use the EN setup software to m...

Page 21: ...s is normally set to 1000 The EN creates subdirectories under a single Destination DIR When the number of files in the subdirectory reaches 1000 then the EN automatically creates another subdirectory...

Page 22: ...ht Sensor This will activate the connection to the light sensor If the connection is successful you should see a live data change in the ADR Debug side A B registers Also you should see what camera pa...

Page 23: ...n does not generate Flash because they are independent from normal trigger operation Normally Flash and Night Light are controlled by ADR and a light sensor To take advantage of this feature connect t...

Page 24: ...he NTP drift file is empty then the NTP will take about 1 hour to optimize the time During the initialization NTP Status must show USYNC and NTP estimated error is max After 3 4 hours the time drift w...

Page 25: ...ctly the same as the previous Telnet solution except that you do not need an Ethernet connection If Ethernet is down or if the IP of the camera is unknown this method is useful You can use ifconfig or...

Page 26: ...reset signals sent to CCD IRQ count number of interrupt generated by FPGA to PowerPC By generating an Ethernet trigger All and HW Trigger button on the EN setup video window you can see only VINIT and...

Page 27: ...ht click on the camera icon you want to upgrade Select Update Firmware in Camera s You can update the five pieces of firmware inside the EN camera Each piece of firmware has a distinctive extension Ta...

Page 28: ...we suppose we have accidentally assigned an invalid IP address to the EN camera and now we cannot communicate with the EN camera over Ethernet When this happens there are two recovery methods The firs...

Page 29: ...dress Enter the new IP address After setting the new IP address type 0 to exit the monitor menu After the boot up sequence login to the serial terminal Username root Password JAIPULNiX Type en v versi...

Page 30: ...a temporary IP assignment because the EN camera will lose this setting once you restart it Now you should be able to telnet to the EN cameras If you want to assign the new IP address permanently you c...

Page 31: ...elnet login to EN camera as ROOT with the following user name and password user name root password JAIPULNiX Type en v to see the version numbers for all firmware currently running Ex en v version txt...

Page 32: ...g the EN setup software To do so follow the steps below 1 Start the EN setup software 2 Click the Properties button 3 Right click on the camera and select Update Firmware 4 Select Update OS Image 5 Re...

Page 33: ...er this command ifconfig eth0 10 0 0 65 netmask 255 255 255 0 4 Via FTP manually send the firmware file to the usr local bin directory of the EN camera 5 Run test_bcs utility Ex test_bcs a en_YYMMDDVR...

Page 34: ...EN Camera Series 24 Uploading Firmware...

Page 35: ...232 Power PC debug port 5 GND digital 11 Reserved 6 Trigger input 12 TXD RS 232 PowerPC debug port 5 1 2 High Density 26 Pin D Sub Connector The EN camera has a 26 pin MDR26 connector 3M part number...

Page 36: ...rnet RxD B 3 Ethernet RxD B 7 N C 4 N C 8 N C 5 2 RS 232 Communication Cable Figure 13 Serial Communications Cable RS 232B 12 JAI Inc part number 310 132 19 The RS 232B 12 interface cable is used to d...

Page 37: ...sing a terminal strip or directly When wiring the PD 12UU and PD 12UE power supplies directly please note the following The lead ends must be twisted together and tin soldered for strength and electri...

Page 38: ...ow these directions to properly attach the power cable to the camera connector 1 Rotate the connector while applying slight pressure until the keyways line up 2 Press the connector into place until fi...

Page 39: ...ical shutter or strobe light in order to freeze the object motion The TS 2030EN model 1920 x 512 resolution enables the 30Hz frame rate by scanning 512 lines out of the entire 1080 lines This techniqu...

Page 40: ...EN Camera Series 30 Camera Features Figure 15 Timing Chart 1 TS 2030EN...

Page 41: ...Camera Features 31 EN Camera Series Figure 16 Timing Chart 2 TS 1327EN...

Page 42: ...environments with a different lighting conditions lenses or optical filters The raw A side reading of the light sensor is multiplied by ADR LS Gain for Side A If LSA_Gain 1 0 the light sensor value be...

Page 43: ...Ratio ADR White to Blue Ratio is the ratio between a white plate and blue plate and is used to optimize the camera parameters This value is optimized by JAI and should be kept at factory default Plea...

Page 44: ...User needs to set appropriate ADR Shutter Max and ADR Shutter Min config registers Address 53 and 58 respectively to limit exposure time In daytime ADR Shutter Min limits the shortest exposure time o...

Page 45: ...4 3 60 11 4 205 19 83 12 9 255 21 112 14 9 143 16 8 176 18 9 200 20 5 230 22 4 255 24 0 Note Gain Value is Gain entry in camera LUT after calibration Table 8 Gain Table Color EN Camera TSC 2030EN TSC...

Page 46: ...typically used by the lane controller to send serial trigger or to send DatalD message to validate the HW TTL trigger RS 485 is a differential signal communication for longer distance Since RS 485 is...

Page 47: ...e curve degrades white balancing Only linear LUT is used Also it is important to keep in mind that a lossy JPEG encoding will cause color information loss Viewer software cannot reconstruct the color...

Page 48: ...the lane controller on TCP message based image transfer Half image and quarter images are supported only on the UDP setup channel The raw image format is the only one supported by the UDP setup channe...

Page 49: ...9720 Color 2030 BW 2030 Color 2076 BW 2076 Color 1327 BW 1327 Color TiF queue size 20 25 15 20 10 13 15 15 JPEG size 20 0 15 0 10 0 15 0 Please refer to the EN to LC Interface Document for more infor...

Page 50: ...is recycled the EN camera will read the saved NTP Drift file and the next settlement will not take too long If NTP is still not synchronized with the NTP server s NTP status register address 239 show...

Page 51: ...t PC 2 If you have a firewall set up on your Windows computer disable it Also be sure to enable network data transfer of the EN setup software 3 If the EN camera s IP address is unknown use the RS 232...

Page 52: ...d modify create directories 2 If anonymous user is not used make sure that the User Name and Password on the FTP client register settings on the EN side match those of the FTP server setting on the ho...

Page 53: ...hange the following parameters 3 Operation Mode TCP Server mode TCP alive check time 1 min Ignore jammed IP YES 4 Repeat the same changes to Operating Settings Port 2 5 Make sure to add 120Ohm termina...

Page 54: ...dress 42 decimal so that flash status is Normally Low Goes High at alarm 3 After changing the register save the setting to FlashROM 7 16 Problem 16 Timestamp is Not Set to Current Local Time 1 Use the...

Page 55: ...H x 768 V S N Ratio 50dB min BW 48dB min Color Video Output Digital output JAI Inc proprietary protocol over TCP IP Gamma Gamma 0 55 forBW Linear for Color Lens Mount C mount Power Req 12V DC 10 450 m...

Page 56: ...er No delay async shutter 1 15 1 32 000 Spectral response 400 800 nm mono 300 750 nm color Lens mount C mount use 2 3 format lenses Power requirement 12V DC 10 420 mA typical at 25 C 900 mA powerup su...

Page 57: ...Specifications 47 EN Camera Series 8 2 Physical Dimensions Figure 19 Physical Dimensions 8 3 Spectral Response Figure 20 Spectral Response B W CCD TS 2030EN TS 2076EN...

Page 58: ...EN Camera Series 48 Specifications Figure 21 Spectral Response B W CCD TS 1327EN Figure 22 Spectral Response Color CCD TSC 2030EN TSC 2076EN...

Page 59: ...23 Spectral Response Color CCD TSC 1327EN Table 11 IR Cut Filter Optical Characteristics Wavelength Transmission from 450 to 650 nm Average 80 above 730 20 am Average 50 from 800 to 1 150 nm Average...

Page 60: ...EN Camera Series 50 Specifications Figure 25 Red Filter Optical Characteristics...

Page 61: ...Options 51 9 Configurable Order Options for EN Cameras 9 1 OP IR Monochrome only No IR cut filter 9 2 OP RED Monochrome only Red filter...

Page 62: ...52...

Page 63: ......

Page 64: ...www jai com Europe Middle East Africa Phone 45 4457 8888 Fax 45 4491 8880 Asia Pacific Phone 81 45 440 0154 Fax 81 45 440 0166 Americas Phone Toll Free 1 800 445 5444 Phone 1 408 383 0301...