Setting range
Default value
Description
Logic Block 0,
Logic Block 1
Logic Block 0
Specifies the Logic Block to configure.
Logic Block Function
AND
AND
Selects the combinational logic Function of the Logic Block to configure.
Logic Block Input Selector
0, 1
0
Selects the Logic Block's input to configure.
Logic Block Input Source
ー
Line4 TTL In 1
Selects the source signal for the input into the Logic Block.
[Setting range]
Exposure Active, LVAL,
Pulse Generator 0, Pulse Generator 1, Pulse Generator 2, Pulse Generator 3,
User Output 0, User Output 1, User Output 2, User Output 3,
Line4 TTL In 1, Line5 Opt IN 1, Line10 TTL In 2, Line13 TTL In 3,
Logic Block 0, Logic Block 1,
Encoder Trigger
Logic Block Input Inverter
True, False
Selects if the selected Logic Block Input source signal is inverted.
Logic Block Output Inverter
True
True
Selects if the selected Logic Block Output signal is inverted. (True fixed)
Setting range
Default value
Description
Configure settings for action control.
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if this ActionDeviceKey matches the
DeviceKey contained in the action command message.
ー
256 (Fixed)
Indicates the size of the scheduled action commands.
0,1,2,3
0
Select the ActionSelector.
Action Group Mask
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if the result of an AND operation of
GroupMask contained in this ActionGroupMask and an action command
message is not 0.
Action Group Key
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if this ActionGroupKey matches the
GroupKey contained in the action command message.
j) Logic Block Control
Logic Block Selector
Action Queue Size
k) Action Control
Action Device Key
Action Selector
Item
Item
SW-4000Q-SFP
—