SW-2001T-CL
16
Important note:
•
If using individual exposure, the EEN signal represents the channel with the longest exposure time
Fig. 12 Shutter-Select mode with External trigger (and individual exposure)
6.6.5.
Pulse Width Control (PWC) mode
In this mode, the user has full control of both the line rate and the exposure time of each line via
the External Trigger input.
At the falling edge of the External Trigger signal, the exposure is initiated, and at the rising edge
the exposure is terminated and read out. The camera can accept an external trigger through the
Camera Link connector or though the 12-pin connector.
To use this mode:
Set function
Trigger mode, PWC
TR=2
Important Note:
•
Possible pulse width:
1.2
μs
ec. to 2 sec. (there is no upper limit for the pulse width, but to avoid image deterioration it
is recommended not to exceed 2 seconds.
•
One-push white balance by gain setting only.
•
When the one-push white balance has been initiated and the rear panel LED shows orange, the
camera must receive continuous external trigger pulses corresponding to the frequency and duty