SW-2001T-CL
15
EI=1(tracking with G)
Programmable exposure
PER/PEG/PEB=80 to 2150400 (in 25ns steps)
Important note:
•
If using individual exposure, the EEN signal represents the channel with the longest exposure time
Fig. 11 Shutter-Select mode with Internal line rate generator (and individual exposure)
6.6.4.
Shutter-Select mode with External trigger
This mode allows the user to have full control of the exposure time, by programming a timing
generator, while the line rate is controlled by an external trigger signal. The camera can accept an
external trigger through the Camera Link connector or though the 12-pin connector.
To use this mode:
Set function
Trigger
TR=1
Trigger origin, external
TG=1
Individual R, G and B exposure
EI=0(individual)
EI=1(tracking with G)
Programmable exposure
PER/PEG/PEB=80 to 2150400 (in 25ns steps)