SP-5000M-CXP2 / SP-5000C-CXP2
- 36 -
7.2.3 Exposure Auto
This is a function to control the exposure automatically. It is effective only for Timed.
JAI ALC Reference controls the brightness.
There are three modes, OFF, Once and Continuous.
OFF:
No exposure control
Once:
Exposure adjusts when the function is set, then remains at that setting
Continuous:
Exposure continues to be adjusted automatically
In this mode, the following settings are available.
ALC Speed:
Rate of adjustment can be set
ASC Max:
The maximum value for the exposure time to be controlled can
be set
ASCMin: The minimum value for the exposure time to be controlled can
be set
ALC Reference:
The reference level of the exposure control can be set
ALC Channel area:
The measurement area of the exposure control can be set
Associated GenICam register
GenICam
Name
Access
Values
Category
Exposure
Auto
R/W
Off
Continuous
Once
Acquisition Control
Exposure
Auto Max
R/W
100
to
1000000
JAI-Custom
Exposure
Auto Min
R/W
100
to
1000000
JAI-Custom
7.3. Trigger Control
7.3.1 Trigger Source
The following signals can be used as the trigger source signal.
OFF
Line 5 (Input to Opt In 1 and output from Digital IO
Line 4 (Input to TTL In1 and output from Digital IO
User Out 0 to 3
Trigger Packet IN
Soft Trigger
Pulse Generator 0 to 3
NAND1/NAND2
7.3.2 Trigger activation
This command can select how to activate the trigger.
Rising Edge:
At the rising edge of the pulse, the trigger is activated.
Falling Edge: At the falling edge of the pulse, the trigger is activated.
Level High: During the high level of trigger, the accumulation is activated
Level Low:
During the low level of trigger, the accumulation is activated
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.