![JAI SP-5000M-CXP2 User Manual Download Page 37](http://html1.mh-extra.com/html/jai/sp-5000m-cxp2/sp-5000m-cxp2_user-manual_3238525037.webp)
SP-5000M-CXP2 / SP-5000C-CXP2
- 35 -
Table37. The combination of Exposure Mode, Trigger Option and Trigger Mode
Exposure Mode
Trigger Option
Trigger Mode
(Frame Start)
Operation
OFF
N/A
N/A
Self-running operation
Exposure control by Exposure
Time is not possible
Timed
OFF
OFF
Self-running operation
Exposure control by Exposure
Time is not possible
ON
Timed (EPS) Operation
Exposure can be controlled by
Exposure Time
RCT/
RCT continuous
Forced to ON
RCT Operation
Exposure can be controlled by
Exposure Time
PIV
Forced to ON
PIV Operation
Exposure can be controlled by
Exposure Time
Trigger Width
N/A
Forced to ON
Exposure is controlled by the
pulse width of the external trigger
Table 38. Associated GenICam register information
GenICam Name
Access Values
Category
Exposure Mode
R/W
Off
Timed
TriggerWidth
Acquisition Control
Trigger Mode
R/W
Off
On
Acquisition Control
Trigger Option
R/W
Off
RCT
PIV
RCT Continuous
JAI-Custom
7.2.2 Exposure Time
This command is effective only when Exposure Mode is set to Timed. It is for setting exposure time.
The setting step for exposure time is 1
μ
sec per step.
Minimum:
10
μsec
Maximum:
8 seconds
Associated GenICam register
GenICam
Name
Access
Values
Category
Exposure
Mode
R/W
Off
Timed
TriggerWidth
Acquisition Control
Exposure
Time
R/W 10
to
1000000 [us]
Acquisition Control
Exposure
Time
Raw
R/W
10
to
1000000 [us] Acquisition Control