SP-12401M-USB/SP-12401C-USB
— 28 —
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The
shortest repetition periods for triggers cannot be lower than that value.
The above table indicates the shortest trigger periods for when [TriggerOverLap] is set to
[Readout]. When [TriggerOverLap] is set to [Off], even when the exposure time is shorter
than the frame period, the cycle may be extended.
■
SP-12401M-USB
■
SP-12401C-USB
BayerRG8
BayerRG10Packed BayerRG12Packed
BayerRG10,
BayerRG12
BGR8
BGR10p
Full
42.7ms
42.7ms
49.1ms
65.4ms
98.1ms
122.7ms
ROI (Height = 1500)
21.6ms
21.6ms
24.5ms
32.7ms
49.1ms
61.3ms
ROI (Height = 750)
11.1ms
11.1ms
12.3ms
16.4ms
24.5ms
30.7ms
Scanning range
Shortest period of trigger
Mono8
Mono10Packed
Mono12Packed
Mono10,
Mono12
Full
42.7ms
42.7ms
49.5ms
66.0ms
ROI (Height = 1500)
21.5ms
21.5ms
24.7ms
32.9ms
ROI (Height = 750)
11.0ms
11.0ms
12.3ms
16.4ms
BinningVertical2
42.7ms
42.7ms
42.7ms
42.7ms
Scanning range
Shortest period of trigger
Summary of Contents for SP-12401M-USB
Page 72: ...SP 12401M USB SP 12401C USB 72 SP 12401C USB Sensitivity Wave length nm Sensitivity ...
Page 73: ...SP 12401M USB SP 12401C USB 73 Dimensions Dimenstional tolerance 0 3mm Unit mm ...
Page 77: ...SP 12401M USB SP 12401C USB 77 Revision Date Changes Revision history 1 1 Jan 2021 China RoHS ...