RM/TM-1405GE Series
36
Configuring the Camera
SensorDigitizationTaps
: the TM-1405GE is a single tap camera and uses one channel to read out
images from the image sensor.
WidthMax
: shows the current valid maximum value for Width.
HeightMax
: shows the current valid maximum value for Height.
Width
: sets the width of the output image. When ScanMode is changed it is necessary to set this
value to equal to or less than WidthMax.
Height
: sets the height of the output image. When ScanMode is changed it is necessary to set this
value to equal to or less than HeightMax.
OffsetX
: specify the offset from the left edge of the image captured by the sensor to be sent out of
the camera. Width must be set lower than WidthMax before this value can be increased.
OffsetY
: specify the offset from the top of the image captured by the sensor to be sent out of the
camera. Height must be set lower than HeightMax before this value can be increased.
•
Offset Example:
•
ScanMode is set to A_1392x1040
•
Width to 600 and Height to 100.
•
OffsetX can have a range of 0 to 40. OffsetX is then set to 20.
•
OffsetY can have a range to 0 to 80. OffsetY is then set to 35.
•
The resulting image is of size 600x100 with the upper left pixel offset by 20 pixels horizontally
and 35 vertically
Figure 12.
Image Output Example.
PixelFormat
: specifies the image type captured from the image sensor. Available options:
Monochrome:
•
Mono8: 8-bit monochrome image.
•
Mono10: 10-bit monochrome image with 1 pixel needing 2 bytes.
•
Mono10Packed: 10-bit monochrome image with 2 pixels packed into 3 bytes.
Bayer: BayerGB patterns are used for Programmable User Scan Area with odd numbered starting
row.
•
BayerRG8: 8-bit Bayer pattern with Red and Green pixels in first row.
•
BayerGB8: 8-bit Bayer pattern with Green and Blue pixels in first row.
•
BayerRG10: 10-bit Bayer pattern with Red and Green pixels in first row.