LT-400CL
56
Black level
Master tracking mode:
Master(Green) : 0 to 127LSB
Red/Blue : ± 64LSB (against the master value)
Individual mode:
Red/Green/Blue : 0 to 127LSB
White balance
Adjustable range : 4000K to 9000K
Standard color temperature : 7800K
Knee control
Knee point : 0 to 1023
Knee slope: x0.000015 to x1.0000
Flat field correction
PRNU within ±5% after correction (at 100% output)
DSNU within ±5% after correction (at 0% output)
Shading correction
1. Flat shading correction
2. Color shading correction
Electronic shutter
Available for Shutter-select mode
Adjustable range :60μs to 14.9ms
Adjustment increments : 12.5ns(1 clk)
Operation mode
No-shutter (Internal/External trigger)
Shutter-select (Internal/External trigger)
Pulse Width Control (PWC)
Trigger input
Hirose12-pin: 4.0
±
2.0Vp-p
TTL or
Camera Link: LVDS (CC1)
Possible to change Negative Logic or Positive Logic
Sync output
(open termination)
Camera Link LVAL, DVAL, EEN
Hirose 12-pin XEEN (Negative logic) 4.0 Vp-p (no termination)
Test pattern gen.
Color bar, gray 1, 2 and white, 890 LSB
Communication
interface
Via Camera Link connector or RS-232C (Hirose 12-pin
connector)
Baud rate: 9600bps,19200bps,38400bps,57600bps,115200bps
Camera Link and Hirose 12P cannot be used at the same time.
Power
DC +12V-10% to +24V + 10%
Typical: 450mA (No-shutter/internal, lens cap on)
Max.: 480mA (No-shutter/internal, at saturation level)
Note: Use a power supply with more than 3A current
Lens mount
LT-400CL-M52 M52 lens mount ( Standard)
LT-400CL-F Nikon F-Mount (Factory option)
Maximum allowed rear protrusion on lenses: 13 mm
Flange back distance
M52 mount/Nikon F-Mount : 46.5mm
tolerance: 0
~
-0.05mm
Optical axis
Center
±
0.1mm(Max)
Operating
temperature
/Humidity
- 5
C to +45
C / 20 to 80% ( non-condensing)
Storage temperature -25
C to +60
C, 20 to 80% ( non-condensing)