6.4.5 Pulse width control (PWC) mode
In this mode, the user has full control of both the line rate and the exposure time of each line
via the External Trigger input.
At the rising edge of the External Trigger signal, the exposure is initiated, and at the falling
edge the exposure is terminated and read out. The camera can accept an external trigger
through the Camera Link connector or through the 12-pin Hirose connector.
To use this mode:
Set function
Trigger mode, PWC
TR=2
Important Note:
The minimum trigger interval
Scan mode
Trigger input via
Minimum interval (
µ
s)
Full/Binning
Camera link
Exposure time + 33.4125
Hirose 12-pin
Exposure time + 37.9125
Sub-sampling/windowing
Camera link
Exposure time + 20.6125
Hirose 12-pin
Exposure time + 25.1125
The minimum trigger pulse width
Trigger input via
Minimum trigger pulse width
Camera link
33.4125µs
Hirose 12-pin
37.9125µs
One-push white balance by gain setting only.
When the one-push white balance has been initiated and the rear panel LED shows orange,
the camera must receive continuous external trigger pulses corresponding to the frequency
and duty cycle used in the application.
Fig. 46 Pulse Width Control mode