— 26 —
GO-5101M-PMCL / GO-5101C-PMCL
■
1X2-1Y
1X2-1Y is a 2-tap output format as defined in GenICam tap geometry.
1X3-1Y
1X3-1Y is a 3-tap output format as defined in GenICam tap geometry.
Page 1: ...ludes important safety precautions and instructions on how to operate the unit Be sure to read this manual to ensure proper operation 2017 JAI User Manual GO 5101M PMCL GO 5101C PMCL 5 1M Digital Prog...
Page 2: ...Combinations 25 Camera Output Formats 25 1X2 1Y 26 1X3 1Y 26 1X4 1Y 27 Cable length reference 27 Acquisition Control Image Acquisition Controls 27 Changing the Frame Rate 27 Maximum frame rate period...
Page 3: ...ested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...
Page 4: ...ion of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period...
Page 5: ...ion of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period...
Page 6: ...ic to CMOS image sensors The following phenomena are known to occur on cameras equipped with CMOS image sensors These do not indicate malfunctions Aliasing When shooting straight lines stripes and sim...
Page 7: ...or A separate power supply and or conversion cable not supplied is required Output formats You can choose from 8 bit 10 bit and 12 bit output for both monochrome and Bayer As the color camera cannot p...
Page 8: ...mera Frame grabber board Computer Parts Identification 1 Lens mount C mount Mount a C mount lens microscope adapter etc here Before mounting a lens be sure to refer to Step 2 Connecting Devices page 1...
Page 9: ...k CL Clock 6 19 Out X_OUT3 Data out 7 20 In SerTC RxD LVDS Serial Control 8 21 Out SerTFG TxD 9 22 In CC1 Trigger JAI standard trigger 10 23 In CC2 Reserved 11 24 N C 12 25 N C 13 14 Shield Power Retu...
Page 10: ...pin round Connect the cable for a VA 044F or PD 4P GO Power Supply optional or for DC IN trigger IN here 1 2 3 4 Compatible connectors Camera side 09 3111 81 04 Binder Cable side 79 3108 52 04 Binder...
Page 11: ...oftware first time only When using the camera for the first time install the software for configuring and controlling the camera JAI SDK on the computer When you install JAI SDK JAI Camera Control Too...
Page 12: ...ing the camera via JAI SDK Checking the frame grabber board s settings Settings must be configured on the frame grabber board to enable Gen CP support For details refer to the operating instructions f...
Page 13: ...rect connection or MP 43 tripod adapter plate 6 DC IN trigger IN connection cable not supplied 1 Lens 3 Camera Link cable 4 Frame grabber board 5 Computer to external trigger or 7 AC adapter not suppl...
Page 14: ...by the camera 3 Camera Link cable Connect the Camera Link cable to the Mini Camera Link connector Use a cable that supports the Camera Link standard and is compatible with Mini Camera Link SDR connec...
Page 15: ...o read the LEDs see LED status and camera status page 10 in the Parts Identification section Note If the power trigger LED does not switch to green within minutes of supplying power check the Camera L...
Page 16: ...0 pixels Pixel Format GO 5101M PMCL Mono8 GO 5101C PMCL BayerRG8 You can specify the image acquisition area For details see ROI Regional Scanning Function page 38 1 Select the Feature Properties tab a...
Page 17: ...Selector trigger operation Frame Start Trigger Mode Off Trigger Source trigger signal source Line7 CC1 Trigger Activation trigger polarity Rising Edge rising edge of input signal Exposure Mode Timed...
Page 18: ...et to Off If Exposure Auto is set to Continuous temporarily set it to Off before changing the exposure time 3 Set Trigger Selector to Frame Start Frame Start is the default setting 4 Set Trigger Mode...
Page 19: ...ure time in Exposure Time The setting value for the exposure time can only be changed when Exposure Auto is set to Off If Exposure Auto is set to Continuous temporarily set it to Off before changing t...
Page 20: ...16 are 100 and 1600 respectively For the GO 5101C PMCL the Digital Red digital R gain and Digital Blue digital B gain can be set to a value from x0 45 to x5 62 7 dB to 15 dB the Digital All master gai...
Page 21: ...ue in Black Level Step 6 Configuring Various Other Settings See Settings List page 46 and configure settings as necessary Step 7 Saving the Settings The setting values configured in Control Tool will...
Page 22: ...actory default setting values are stored in Default and cannot be overwritten 3 Select User Set Save and click Execute User Set Save Command The current setting values are saved as user settings To lo...
Page 23: ...rt Trigger Binning Vertical 1 Binning Horizontal 1 Exposure Time ROI Balance White Auto 2 Gain Auto Exposure Auto Sequencer Trigger Sequencer Mode Command Sequencer Mode Off Off 1 1 Off 1 2 2 1 2 2 Ti...
Page 24: ...for a variety of purposes such as noise removal for trigger signals and phase adjustment for pulse outputs Such functions are generally referred to as GPIO functions Signals are selected as follows W...
Page 25: ...e Signals to use as output LOW HIGH Software Line 4 TTL In Line 7 CC1 Pulse Generator 0 User Output 0 User Output 1 NAND 0 Out NAND 1 Out Exposure Active Frame Active Frame Trigger Wait FVAL LVAL Trig...
Page 26: ...26 GO 5101M PMCL GO 5101C PMCL 1X2 1Y 1X2 1Y is a 2 tap output format as defined in GenICam tap geometry 1X3 1Y 1X3 1Y is a 3 tap output format as defined in GenICam tap geometry...
Page 27: ...on type and maker Acquisition Control Image Acquisition Controls Perform operations and configure settings related to image capture in Acquisition Control On the GO 5101 PMCL acquisition control alway...
Page 28: ...r FR_Cont 1 H Period Height 34 Maximum frame rate FR_TrOloff 1 1 FR_Cont ExposureTime When Frame Start trigger is On and Trigger OverLap is Readout Maximum frame rate of sensor FR_Cont 1 H Period Heig...
Page 29: ...of the trigger input signal This allows long exposure The settings for exposure control and triggers are related to each other Be sure to configure the settings described in Configuring Exposure and...
Page 30: ...rmed via external trigger signals The Frame Start trigger allows exposure control via the trigger signal inputs The settings for exposure control and triggers are related to each other Be sure to conf...
Page 31: ...N A B C Readout duration Next trigger disabled Next trigger input enabled Tap Geometry CL Pixel Clock MHz Period from Trigger start edge to Exposure start A usec Period from Exposure end to FVAL start...
Page 32: ...next trigger start C usec Max Exposure msec Min Exposure usec 1X2 1Y 37 125 101 851 851 Expo Current Expo Next 69 116 34 1X2 1Y 74 25 51 435 934 Expo Current Expo Next 34 558 17 1X2 1Y 84 85 45 384 9...
Page 33: ...n function and consists of analog gain digital gain Analog gain is used for lower gain and analog gain digital gain is used when the gain becomes high R and B can be configured individually as digital...
Page 34: ...ex GO 5101M PMCL 0 to 256 GO 5101C PMCL 0 to 256 Select the LUT index to configure Indexes represent the possible pixel values captured on the sensor from the lowest value Index 0 to the highest Index...
Page 35: ...linear Example of the light emitting properties of the monitor display To use the gamma function Configure the settings as follows Item Setting value selectable range Description Gamma 0 45 0 60 1 0 O...
Page 36: ...guring settings interpolation may not be performed 2 Specify the pixel points for interpolation using the Blemish Detect Position X and Blemish Detect Position Y settings Each point is saved to the ca...
Page 37: ...h this level Within 30 of adjustment range Color Shading GO 5101C PMCL only R channel and B channel properties are adjusted by using the G channel shading properties as a reference Pre correction Post...
Page 38: ...irection 1 x 2 or 2 x 1 or in both directions simultaneously 2 x 2 binning Applying binning to a specific field of view results in greater pixel sensitivity with reduced resolution in the direction s...
Page 39: ...er Mode and Sequencer Mode Select to enable the Sequencer and select a mode of operation Trigger Sequencer mode With this mode the Sequencer Trigger pattern is predetermined by the user The user defin...
Page 40: ...Exposure 128 Gain128 M Red Blue Black Level128 Binning128 H V LUT Enable128 Frame Count128 Next Index128 Index Selector MUX Index Table Index Next Index Current Index Command Reset Sequencer Index Re...
Page 41: ...Control will be applied to any index where Sequencer LUT enable has been set to ON Sequencer Index Frame Count Sequencer ROI Next Index and Reset Sequencer Index are not used in Command Sequencer mod...
Page 42: ...ALC Reference is set to 100 video levels will be maintained at 100 for AGC and ASC Automatic gain level control Set Gain to Continuous Detailed Settings for Gain Auto Automatic Gain Level Control When...
Page 43: ...This function is useful for verifying error conditions via the count value using internal camera operations Counting is performed at frame trigger frame start exposure start and exposure transfer end...
Page 44: ...the counter function Configure the settings as follows Three counters can be configured Counter 0 to 2 Item Setting value selectable range Description Counter 0 to 2 Counter 0 to 2 Select the counter...
Page 45: ...t 8 10 12 bit 8 10 bit Differences in camera operation When video process bypass mode is disabled All video processes are enabled Sensor Block Gain All Vertical Binning BlackLevel Block R B Black Leve...
Page 46: ...Display the maximum image height Sensor Digitization Taps 12 Bit 12 Bit Displays the pixel depth output from the sensor Width Max 2464 2464 Display the maximum image width Height Max 2056 2056 Display...
Page 47: ...ulse Generator 0 User Output 0 User Output 1 Line4 TTL In Line7 CC1 NAND0 Out NAND1 Out Line7 CC1 Select the trigger signal source Trigger Activation Rising Edge Falling Edge Rising Edge rising edge o...
Page 48: ...for Trigger Sequencer Sequencer Width 96 to 2464 2464 Set the width of the selected Sequencer Index Sequencer Height 2 to 2056 2056 Set the height of the selected Sequencer Index Sequencer Offset X 0...
Page 49: ...e Low LineSource Low High Frame Trigger Wait Frame Active Exposure Active FVAL Pulse Generator 0 User Output 0 User Output 1 Line4 TTL In Line7 CC1 Nand 0 Out Nand 1 Out Low Select the line source sig...
Page 50: ...width of the pulse in milliseconds The duration between the Start Point and End Point is calculated The setting range varies depending on the Clock Pre scaler value Pulse Generator Repeat Count 0 to 2...
Page 51: ...to 7999999 100 Set the minimum value for the Exposure Auto ASC control range ASC Max 101 to 8000000 8216 Set the maximum value for the Exposure Auto ASC control range AGC Min 100 to 1599 100 Set the...
Page 52: ...When this is set to Off shading correction data is not saved Perform Shading Calibration Execute shading correction Shading Detect Result Display the shading correction results o JAI Custom Control Co...
Page 53: ...d solution Gradation in dark areas is not noticeable Use the gamma function to correct the display As the light emitting properties of the monitor are not linear the entire image may be darker or the...
Page 54: ...H 2056 V Bayer 2464 H 2056 V ROI Width 96 to 2464 16 pixels step 96 to 2464 16 pixels step Offset X 0 to 2448 16 pixels step 0 to 2448 16 pixels step Height 2 to 2056 2 line step 2 to 2056 2 lines ste...
Page 55: ...in connector Input range DC 12 V to 24 V 10 via input terminal Power consumption 2 88 W Typ 12 V input PoCL Input range DC 12 V 10 Power consumption 2 88 W Typ 12 V input Lens mount C mount Lens mount...
Page 56: ...6 9 fps 1 4 MP 1408 1050 ROI 3 45 3 45 1 2 6 6 04 mm 68 7 fps 1 3 MP 1280 1024 ROI 3 45 3 45 1 2 8 5 66 mm 70 4 fps 0 5 MP 800 600 ROI 3 45 3 45 1 4 6 3 45 mm 117 5 fps 0 5 MP 800 600 Mono only ROI 2...
Page 57: ...PMCL 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 400 500 600 700 800 900 1000 Sensitivity wave length nm Rch Gch Bch Dimensions 12 20 41 5 23 7 22 29 29 18 19 2 C Mount 10 12 5 14 3 M3 Depth 3 4 M2 Depth...
Page 58: ...ks Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries Intel and Intel Core are trademarks of Intel Corporation in the Unite...
Page 59: ...rties 46 Frame Rate 27 Frame Rate Reference 56 G Gain Auto 42 Gain Control 33 Gain Level 42 Gamma Function 35 GPIO 24 I Initial Settings for the Camera 15 Installing the Software 11 J JAI Camera Contr...
Page 60: ...Revision history Revision Date Changes 1 0 Mar 2017 First draft 1 1 May 2017 Power supply...