CV-M91
- 10 -
6.2.1. Continuous Operation (Non triggered)
Trigger Mode Normal. It is for applications where the camera is continuous running without
external trigger. The shutter will work in all 8 steps up to 1/10,000 second.
Refer to “7. Configuring the Camera.”
To use this mode:
Set function:
Trigger mode “Normal”. SW1-4 to OFF
On PK8407: JP301 open, JP302 open, JP331 short.
Factory setting.
Accumulation to “Frame” or “Field”. SW 301-4 to ON or OFF
Scanning to “Interlaced” or “Non-Interlaced”. SW 1-5 to OFF or ON
“Shutter Speed”. SW1-1 through 1-3 to optimum
Other
functions
Important notes on using this mode.
Fig. 13. PAL horizontal timing
Fig. 14. NTSC horizontal timing