background image

Nivel System CLS-3

  

Laser Detector

 

User Manual 

 

 

  

ver. 

EN

 

 

1. Put dry batteries into the battery case and pay attention to the 
right electrode.  
2. Press the key ON/OFF to make the detector power on, and the 
POWER indicator lights.  
3. Move the detector upward(/downward) or left(/right) at 45 
degree angle of the laser measured. When the laser hits the 
receiving window, Both an audible buzzer and the related LED lights.  
4. Locating horizontal laser, set the detector vertically, then move it 
upward or downward to keep the round bubble in the center of the 
circle.  
Locating vertical laser, set the detector horizontally, and then move 
it left or right to keep the long bubble locating at the center of the 
long vial.  
5. When the laser line hits the center of the receiving window, the 
green LED(the one at middle) lights and buzzer will be in a 
continuous beeping.  
6. Move the detector toward to the direction which the red LED 
indicates, and buzzer sound discontinuous beep.  
7. Renew the battery when the power indicator starts to wink 
slowly.(Low voltage alarm.)  
8. The detector will shut off automatically in 7min without any 
operation.  
 

Attentions: 

 

1. This kind of detector only fit for Cross line laser level.  
2. The detector is precision instrument, must avoid the environment with high temperature & high 
dampness/aquosity.  
3. Please remove the battery when not using.  
 

Specification: 

 

Cooperation (laser beam) 

red, green 

Detection accuracy 

 

±1  

Receiving distance 

 

70m  

Working temperature   

- 10 

 

 + 50 

 

Power   

 

 

DC9V alkaline battery  

Size of receiving window 

20mm×21mm  

IP Rate   

 

 

IP54  

Connection thread 

 

1/4” 

Detector adapter 

 

yes 

Dimension 

 

 

140x60x25/mm3  

Weight  

 

 

126g  

 

Nivel System – Service & supprot  

TPI Sp. z o.o., ul. Bartycka 22, 00-716 Warsaw, Poland 

phone.: +48 22 632 91 40, [email protected] 

www.nivelsystem.com

 

 

Reviews: