CM-200 MCL / CB-200 MCL
This command will load previous stored settings to the camera. 3 user settings can be stored in
the camera EEPROM. 1 factory setting is also stored in the camera. The settings stored in the last
used user area is used as default settings at power up.
Save Settings SA
This command will store the actual camera settings to 1 of the 3 user area in the camera EEPROM.
EEPROM Area EA
If received, the camera will return
the last used user area number.
7.4.
CM-200MCL/CB-200MCL command list
Command Name
Format
Parameter
Remarks
A - General settings and utility commands.
1 Echo
Back
EB
=[Param.]<CR><LF>
0=Echo off
Off at power up
EB?<CR><LF>
1=Echo on
Camera Status
Request
ST
?<CR><LF>
2
Actual
setting
Online Help
Request
HP
?<CR><LF>
3
Command
list
3 digits
4 Firmware Version
VN
?<CR><LF>
(e.g) 100 =
Version 1.00
Camera ID
Request
ID
?<CR><LF>
5
max
10
characters
Model Name
Request
MD
?<CR><LF>
6
max
16
characters
User can save and
load free text.(16
or less characters)
7 User
ID
UD
=[Param.]<CR><LF>
UD?<CR><LF>
B – Shutter
1 Shutter
Mode
SM
=[Param.]<CR><LF>
0=Preset Shutter
SM?<CR><LF>
1=Programmable exposure
0=Off, 1=1/60, 2=1/100,
3=1/250, 4=1/500,
5=1/1000, 6=1/2000,
7=1/4000, 8=1/8000,
9=1/10000
2 Preset
Shutter
SH
=[Param.]<CR><LF>
Available when
SM=0.
SH?<CR><LF>
PE
=[Param.]<CR><LF>
2
to
1252
(CM/CB-200)
Programmable
Exposure
Available when
SM=1.
3
PE?<CR><LF>
C - Trigger mode
0=Normal (Continuous)
1 Trigger
Mode
TR
=[Param.]<CR><LF>
1=Pre-select
TR?<CR><LF>
2=Pulse Width
2 Trigger
Polarity
TP
=[Param.]<CR><LF> 0=Active
Low
- 21 –