[Offset Load] and [Gain Load] can load the Factory data or the user data independently.
Four user indexes (0 to 3 )are available for each Offset and Gain.
Use [Load Master Index] to select the same index for both Gain and Offset.
◆
How to store Offset and Gain data
1.
Select the location by Index ( 0 to 3)
2.
Click [Save] for saving data for Offset and Gain
3.
Click [Save RAM to Flash]
Note: Data cannot be stored if the power of the camera is OFF before the execution of
[Save RAM to Flash].
Special Caution: For saving data, Factory settings should not be used. Doing so will
cause Factory default-data to be over-written.
After the setting data is stored in flash memory, when the camera is restarted, the saved
data can be loaded to the camera as the initial settings.
◆
How to load to the RAM Table
Select the table (Factory or User) and Index ( 0 to 3) and read the required Offset and
Gain setting data.