CM-141MCL/PMCL/RA / CB-141MCL/PMCL/-RA
32
Load settings.
LD.
This command will load previously stored settings to the camera. 3 user settings can be
stored in the camera EEPROM. 1 factory setting is also stored in the camera. The settings
stored in the last used user area are used as default settings at power up.
Save Settings.
SA.
This command will store the actual camera settings to 1 of the 3 user areas in the camera
EEPROM.
EEPROM Area.
EA.
If received, the camera will return
the last used user area number.
7.4
CM-140MCL / CB-140MCL command list
Command
Name
Format
Parameter
Remarks
A - General settings and utility commands.
2
Camera Status
Request
ST
?<CR><LF>
Actual setting
3
Online Help
Request
HP
?<CR><LF>
Command list
4
Firmware
Version
VN
?<CR><LF>
3 digits
(e.g) 100 =
Version 1.00
5
Camera ID
Request
ID
?<CR><LF>
max 12
characters
6
Model Name
Request
MD
?<CR><LF>
max 12
characters
7
User ID
UD
=[Param.]<CR><LF>
UD?<CR><LF>
User can
save and load
free text.(12
or less
characters)
B
– Shutter
1
Shutter Mode
SM
=[Param.]<CR><LF>
SM?<CR><LF>
0=Preset Shutter
1=Programmable exposure
2
Preset Shutter
SH
=[Param.]<CR><LF>
SH?<CR><LF>
0=Off
、
1=1/60, 2=1/100
、
3=1/250
、
4=1/500
、
5=1/1000
、
6=1/2000
、
7=1/4000
、
8=1/8000
、
9=1/10000
Available
when SM=0.
3
Programmable
Exposure
PE
=[Param.]<CR><LF>
PE?<CR><LF>
2 to 1052
Available
when SM=1.
4
Fine Exposure
FE
=[Param.]<CR><LF>
FE?<CR><LF>
0 to 4095