background image

Technical Specifications

Item no. 10404040, Revision 14

13 ( 36 )

Coupler plug

9-pin (SpeedTEC)

Weight

~ 6 kg

Inner taper run out

< 1 µ

Axial run-out

< 1 µ

6.1

Dimensions

(*) = Clamping range

Summary of Contents for Z80-H450.03 S5W2

Page 1: ...Manual Z80 H450 03 S5W2 High Frequency Spindle Pneumatic taper change...

Page 2: ...velopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakan...

Page 3: ...borne noise emissions 18 7 Operating location 19 8 Installation 20 8 1 Installing the HF spindle 20 8 2 Diameter of media supply line 21 8 3 Cooling water 21 8 3 1 Quality of cooling water 21 8 3 2 Se...

Page 4: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Page 5: ...ories Available on request q Spindle holder q Frequency converter q Chiller q Collet grease q Further accessories on request Only approved accessories have been tested for operational safety and func...

Page 6: ...nd a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Nakanishi J...

Page 7: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Page 8: ...ay cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure...

Page 9: ...arding this to the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft h...

Page 10: ...the raw data for the frequency converter Use a motor supply line that is as short as possible Adjust the speed of the HF spindle using the FC Refer to the frequency converter manual for further infor...

Page 11: ...revents foreign bodies such as chips and liquids e g emul sions from entering the HF spindle Check that air escapes at the front between the housing and the rotating parts of the HF spindle 5 5 Taper...

Page 12: ...cy 1 667 Hz Motor poles pairs 2 Rated rotation speed 50 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resistor...

Page 13: ...Technical Specifications Item no 10404040 Revision 14 13 36 Coupler plug 9 pin SpeedTEC Weight 6 kg Inner taper run out 1 Axial run out 1 6 1 Dimensions Clamping range...

Page 14: ...167 1 333 1 500 1 667 Hz Rated power 0 194 0 405 0 638 0 844 1 057 1 268 1 482 1 687 1 752 1 783 kW Torque 0 452 0 42 0 432 0 423 0 42 0 418 0 418 0 418 0 387 0 358 Nm Voltage 37 68 95 122 149 177 20...

Page 15: ...1 052 1 320 1 596 1 899 2 108 2 153 2 124 kW Torque 0 581 0 54 0 55 0 532 0 529 0 528 0 539 0 528 0 485 0 437 Nm Voltage 40 74 103 132 161 191 213 213 212 211 V Current 8 8 8 9 8 9 8 9 8 9 8 9 8 9 8 9...

Page 16: ...BN RD BU VT GN WH WH WH RD 0 14 mm BU 0 14 mm BU 0 14 mm YE 0 14 mm GN 0 14 mm BN 0 14 mm BK 0 14 mm Ger testecker FS9 S5 spindle plug FS9 S5 A B C E G H F L D A B C PE Motorphase U motor phase U Mot...

Page 17: ...nal resistance VPTC 2 5 V RN 250 Insulation test voltage Vis 3 kV Response time ta 2 5 s Operating temperature range V 0 Top 25 180 C Resistance values TNAT T R TNAT T VPTC 2 5 V R TNAT T VPTC 2 5 V R...

Page 18: ...resistor Rx is already integrated in the evaluation unit FC u Only connect signal and ground Supply voltage U Rx Signal 8 V 220 1000 mV 8 V 450 2000 mV 12 V 220 1000 mV 12 V 680 3000 mV 15 V 220 1000...

Page 19: ...speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface...

Page 20: ...e and free of strain Seal all connections for compressed air axially in relation to the tightening direction Seal all connections for cooling water axially in relation to the tightening direction If t...

Page 21: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Page 22: ...n air quality see Air purity classes ISO 8573 1 22 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Page 23: ...le without a clamped tool shank If no tool shank is clamped q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q Th...

Page 24: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Page 25: ...r pressure flings out the hollow shank taper in the case of sudden release u Always switch off the taper cleaning when the hollow shank taper is ap prox 1 2 mm away from the contact surface Tip Ensure...

Page 26: ...ion in order to compensate for the ejection travel X Spring loaded X 2 5 mm Spring force 40 80 N 10 2 1 pneumatic taper change During a tool change the tool mount is pressed out of the shaft by the cy...

Page 27: ...ments may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is alwa...

Page 28: ...curately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount and the tool holder must be clean Note Foreign matter reduces the service life u Do not use compressed air...

Page 29: ...zontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relat...

Page 30: ...n More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non recycl...

Page 31: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Page 32: ...equency converter has shut down q Check the error messages in the frequency converter man ual Tool change initiated q Turn off the pneumatic system for the tool change HF spindle becomes hot Cause Tro...

Page 33: ...anually q Do not use technical aids to clamp the HF spindle Bearings damaged q Contact Nakanishi Jaeger GmbH service No automatic tool change Cause Troubleshooting Contamination q Remove all contamina...

Page 34: ...serve all points in the Tool change 25 and Mainte nance 28 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining...

Page 35: ...1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized stan...

Page 36: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z80 H450 03 S5W2 Item no 10404040 Revision 14 Date 01 09 2023 Language EN Jaeger Spindles North Am...

Reviews: