Technical Specifications
Item no. 10406074, Revision 02
27 ( 52 )
6.7
Eddy current sensor (analog, optional accessory)
Order number
1-007
6.7.1
General data
Circuit diagram
Measurement distance
0 … 2 mm
Resolution
< 0.001 mm (static)
< 0.005 mm (dynamic)
Repeat accuracy
< 0.02 mm
Linearity deviation
± 100 µm
Temperature drift
± 5%
6.7.2
Electrical data
Response time
< 1 ms
Operating voltage range
15 … 30 V
DC
Current consumption
max. 10 mA
(without load)
Output circuit
Voltage output
Output signal
0 … 10 V
DC
Load resistance
> 3000 Ω
short-circuit-proof
reverse-polarity-proof