6.  WALL MOUNTED MODEL

6.1.  OVERVIEW 

 Casing made from electrolytic galvanized steel 

 Dynamic Low H

2

O hydrophilic coil 

 Hydraulic  connection  
( 2-pipe  3/4" 

NPT

)

 Hydraulic  connection  
( 4-pipe  1/2" 

NPT

 Condensate tray 

 with 3/4" 

drain connection

 

 

1" filter rack (2" or 4" rack 

upon request)

 Electrical  connection 

 Centrifugal fan(s) with 
double inlet 

6.2.  CONFIGURATION 

BABW/BT

BABW/BF

BABW/FT

BABW/FF

 SUCTION 

 the bottom of the unit 

 the bottom of the unit 

 the front of the unit 

 the front of the unit 

 AIR  OUTLET 

 the top of the unit 

 the front of the unit 

 the top of the unit 

 the front of the unit 

JAGA CANADA   |   BRIZA 26   |    MANUEL    |  2022.09.27   |   V.01

Summary of Contents for BRIZA 26 HIGH PERFORMANCE

Page 1: ...BRIZA 26 HIGH PERFORMANCE MANUAL...

Page 2: ...IT 20 11 WARRANTY 20 12 DISSASSEMBLY INSTRUCTIONS 20 13 REFERENCE STANDARDS 21 DECLARATION OF CONFORMITY JAGA N V Verbindingslaan 16 B 3590 declares under its sole responsibility that the product to w...

Page 3: ...tenance has been carried out by unauthorized people maintenance has been carried out by someone other thanJaga access to the unit has been restricted due to on site conditions the initial start up has...

Page 4: ...the packaging within reach of children 4 INSTALLATION installation must be carried out by certified technicians Incorrect installation could cause product failure a reduced performance or an increase...

Page 5: ...dden Installing the unit in an explosive environment is prohibited Decommissioning When the unit is not used for long periods of time it must be disconnected from the mains electrical connection If th...

Page 6: ...tion for the maximum current required Make sure the electrical supply system complies with current National safety regulations The connections must be implemented in accordance with the diagrams suppl...

Page 7: ...mum permitted water temperature must be taken into account in function of the relative humidity and temperature of the ambient air 5 3 1 PERMITTED MINIMUM WATER TEMPERATURE C AMBIENT TEMPERATURE DRY B...

Page 8: ...3 4 drain connection 1 filter rack 2 or 4 rack upon request Electrical connection Centrifugal fan s with double inlet 6 2 CONFIGURATION BABW BT BABW BF BABW FT BABW FF SUCTION the bottom of the unit...

Page 9: ...GHT 22 22 22 WIDTH 10 10 10 LENGTH 52 63 77 A 62 74 88 B 60 71 85 6 3 DIMENSIONS L 22 13 3 10 L 2 A B B 11 B 2 B A 3 11 2 3 L 11 25 1 15 13 5 Min 3 1 3 1 Dimensions in Inches EN 9 JAGA CANADA BRIZA 26...

Page 10: ...6 3 1 Installation dimensions L 5 7 9 7 5 5 5 5 9 5 10 12 12 10 7 5 6 6 Dimensions in Inches 10 JAGA CANADA BRIZA 26 MANUEL 2022 09 27 V 01...

Page 11: ...sions in Inches 7 INSTALLATION With casing Mark and drill the mounting holes for the back plate and the device 1 8 Without casing Mark and drill the mounting holes for the the device The type of wall...

Page 12: ...CASING 1 Place the screws of the device 5 8 and let them stick out 1 cm 1 2 Place the device in the correct position 3 Tighten the screws 2 1 2 Connect the device electrically 04 208V 60Hz 0 10V Spee...

Page 13: ...sation water is drained quickly 3cm m The condensate drain system must be set up with an adequate p trap in order to prevent the infiltration of odours Always install a plug for cleaning in the lower...

Page 14: ...rews in the mounting holes Ideally the air is blown towards the wall Mount the casing Make sure the mounting holes are in line with the support bolts 1 Secure the casing by tightening the stay bolts 2...

Page 15: ...he unit the top of the unit Dynamic Low H2 O hydrophilic coil Hydraulic connection 2 pipe 3 4 NPT Condensate pump BYOTHERS Hydraulic connection 4 pipe 1 2 NPT Condensate tray with 3 4 drain connection...

Page 16: ...HEIGHT 22 22 22 WIDTH 10 10 10 LENGTH 49 59 74 22 11 10 L 3 L 1 L 13 1 Dimensions in Inches 8 3 1 Installation dimensions max 118 max 118 12 12 5 5 6 6 5 5 Dimensions in Inches 16 JAGA CANADA BRIZA 2...

Page 17: ...that the wall is level and has sufficient loadbearing capacity 01 02 1 Place the screws of the device 5 8 and let them stick out 1 cm Use a washer between screw head and the appliance 1 2 Place the d...

Page 18: ...the hydraulic pipes must be insulated When using devices for cooling iron couplings prohibited 03 Use a back off wrench when faste ning the hydronic connections Remove black plug at hydraulic connecti...

Page 19: ...witch to isolate the unit from the mains before carrying out any maintenance or inspection work Make sure that no one accidentally turns on the power to the unit lock the master switch in the off posi...

Page 20: ...y cleaned the unit has been used in an improper or irresponsible manner repairs have been carried out by others than Jaga product modifications have been carried out by others before or after the inst...

Page 21: ...ssential to the brazing process test conditions assessment and certificates EN 378 1 Refrigerating systems and heat pumps Safety and environmental requirements PREN 378 2 Refrigerating systems and hea...

Page 22: ...27200 20000097 2022 09 27 Jaga Inc Jaga Canada Climate Systems www jaga canada com...

Reviews: