2. WARNINGS AND SAFETY

Handling guidelines:

The unit must be handled with care in order to avoid damage to the unit’s interior and exterior parts.
The unit might have sharp edges; use gloves during installation/adjustment.
All the operations listed below must be carried out in accordance with local health and safety regula-
tions.

Storage conditions:

Up to four packaged units may be stacked on top of each other. All units must be stored in a dry area.

Technical spaces and positioning:

Incorrect installation of the unit may cause noise and vibrations issues.

3. PACKAGING AND COMPONENTS

Follow these instructions when removing the packaging:
– 

  check for any visible damage
– 

  open the packaging
– 

  check if the manual is in the package
– 

  remove the packaging material and put it in the appropriate collection point or recycling facility, in 

compliance with the local regulations.

Dispose of the packaging materials in compliance with the national or local regulations. 

Do not leave the packaging within reach of children.

4. INSTALLATION

– 

  installation must be carried out by certified technicians. Incorrect installation could cause product 

failure, a reduced performance or an increased noise level.

– 

  the unit must be installed in accordance with the local building codes.
– 

  Always use personal protective equipment.
– 

  the unit must remain accessible for inspection and maintenance, the trench must be removable at 

all times.

4.1. ACOUSTIC INSULATION

Sound absorption

Sound is reflected by hard materials. Soft, porous materials are best suited for sound absorption. A 
combination of different materials can reduce the reflection of sound.

Contact noise insulation

Sound travels very easily through hard materials. Soft rubber material can be used to reduce contact 
noise. The effect of this insulation strongly depends on:
– 

  installation method: make sure that vibrations cannot be transferred between different elements, 

e.g. between the built-in heaters and other metallic parts, through pipes, along air ducts etc.

– 

  installation of acoustic insulation in hollow acoustic spaces. Avoid cavities between insulation and 

pipes.

JAGA CANADA   |   BRIZA 26   |    MANUEL    |  2022.09.27   |   V.01

Summary of Contents for BRIZA 26 HIGH PERFORMANCE

Page 1: ...BRIZA 26 HIGH PERFORMANCE MANUAL...

Page 2: ...IT 20 11 WARRANTY 20 12 DISSASSEMBLY INSTRUCTIONS 20 13 REFERENCE STANDARDS 21 DECLARATION OF CONFORMITY JAGA N V Verbindingslaan 16 B 3590 declares under its sole responsibility that the product to w...

Page 3: ...tenance has been carried out by unauthorized people maintenance has been carried out by someone other thanJaga access to the unit has been restricted due to on site conditions the initial start up has...

Page 4: ...the packaging within reach of children 4 INSTALLATION installation must be carried out by certified technicians Incorrect installation could cause product failure a reduced performance or an increase...

Page 5: ...dden Installing the unit in an explosive environment is prohibited Decommissioning When the unit is not used for long periods of time it must be disconnected from the mains electrical connection If th...

Page 6: ...tion for the maximum current required Make sure the electrical supply system complies with current National safety regulations The connections must be implemented in accordance with the diagrams suppl...

Page 7: ...mum permitted water temperature must be taken into account in function of the relative humidity and temperature of the ambient air 5 3 1 PERMITTED MINIMUM WATER TEMPERATURE C AMBIENT TEMPERATURE DRY B...

Page 8: ...3 4 drain connection 1 filter rack 2 or 4 rack upon request Electrical connection Centrifugal fan s with double inlet 6 2 CONFIGURATION BABW BT BABW BF BABW FT BABW FF SUCTION the bottom of the unit...

Page 9: ...GHT 22 22 22 WIDTH 10 10 10 LENGTH 52 63 77 A 62 74 88 B 60 71 85 6 3 DIMENSIONS L 22 13 3 10 L 2 A B B 11 B 2 B A 3 11 2 3 L 11 25 1 15 13 5 Min 3 1 3 1 Dimensions in Inches EN 9 JAGA CANADA BRIZA 26...

Page 10: ...6 3 1 Installation dimensions L 5 7 9 7 5 5 5 5 9 5 10 12 12 10 7 5 6 6 Dimensions in Inches 10 JAGA CANADA BRIZA 26 MANUEL 2022 09 27 V 01...

Page 11: ...sions in Inches 7 INSTALLATION With casing Mark and drill the mounting holes for the back plate and the device 1 8 Without casing Mark and drill the mounting holes for the the device The type of wall...

Page 12: ...CASING 1 Place the screws of the device 5 8 and let them stick out 1 cm 1 2 Place the device in the correct position 3 Tighten the screws 2 1 2 Connect the device electrically 04 208V 60Hz 0 10V Spee...

Page 13: ...sation water is drained quickly 3cm m The condensate drain system must be set up with an adequate p trap in order to prevent the infiltration of odours Always install a plug for cleaning in the lower...

Page 14: ...rews in the mounting holes Ideally the air is blown towards the wall Mount the casing Make sure the mounting holes are in line with the support bolts 1 Secure the casing by tightening the stay bolts 2...

Page 15: ...he unit the top of the unit Dynamic Low H2 O hydrophilic coil Hydraulic connection 2 pipe 3 4 NPT Condensate pump BYOTHERS Hydraulic connection 4 pipe 1 2 NPT Condensate tray with 3 4 drain connection...

Page 16: ...HEIGHT 22 22 22 WIDTH 10 10 10 LENGTH 49 59 74 22 11 10 L 3 L 1 L 13 1 Dimensions in Inches 8 3 1 Installation dimensions max 118 max 118 12 12 5 5 6 6 5 5 Dimensions in Inches 16 JAGA CANADA BRIZA 2...

Page 17: ...that the wall is level and has sufficient loadbearing capacity 01 02 1 Place the screws of the device 5 8 and let them stick out 1 cm Use a washer between screw head and the appliance 1 2 Place the d...

Page 18: ...the hydraulic pipes must be insulated When using devices for cooling iron couplings prohibited 03 Use a back off wrench when faste ning the hydronic connections Remove black plug at hydraulic connecti...

Page 19: ...witch to isolate the unit from the mains before carrying out any maintenance or inspection work Make sure that no one accidentally turns on the power to the unit lock the master switch in the off posi...

Page 20: ...y cleaned the unit has been used in an improper or irresponsible manner repairs have been carried out by others than Jaga product modifications have been carried out by others before or after the inst...

Page 21: ...ssential to the brazing process test conditions assessment and certificates EN 378 1 Refrigerating systems and heat pumps Safety and environmental requirements PREN 378 2 Refrigerating systems and hea...

Page 22: ...27200 20000097 2022 09 27 Jaga Inc Jaga Canada Climate Systems www jaga canada com...

Reviews: