7. ADJUSTING THE WATER TEMPERATURE
7.1. ADJUSTING THE MAXIMUM WATER TEMPERATURE FOR COOLING
By reducing the water temperature setting, the unit will start later. If the
water temperature is set higher, the unit will start sooner .
1. Start setup mode: press and hold the [
-
] button until the blue LED
flashes 5x and release .
2. Short press the [-] or [+] button to adjust the set temperature .
3. Exit setup mode: hold the [-] button until the blue LED flashes 5x and release .
7.2. ADJUSTING THE MINIMUM WATER TEMPERATURE FOR HEATING
By increasing the water temperature setting, the unit will start later. If the water temperature is set
lower, the unit will start sooner .
In combination with a heat pump, it may be necessary to reduce the water temperature .
1. Start setup mode: Press and hold the [
+
] button until the red LED flashes 5x and release .
2. Short press the [-] or [+] button to adjust the set temperature .
12 ̊C
14 ̊C
16 ̊C
18 ̊C
20 ̊C
22 ̊C
24 ̊C
26 ̊C
The blue LED flashes quickly when the minimum temperature is reached.
.
The blue LED flashes quickly when the minimum temperature is reached.
.
The red LED flashes quickly
when the maximum temperature is reached. .
The red LED flashes quickly
when the maximum temperature is reached. .
Automatic control: The green LED lights up when the water temperature (supply water) is lower than the
set temperature
Automatic control: The green LED lights when the water temperature (supply water) exceeds the set
temperature .
24 ̊C
26 ̊C
28 ̊C
30 ̊C
32 ̊C
34 ̊C
36 ̊C
38 ̊C
3. Exit setup mode: press and hold the [
+
] button until the red LED flashes 5x and release .
After 30 seconds, the new settings are automatically saved and the device returns to the
selected mode. .
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
N L
15120045
GND
GND
GND
GND
NTC1
V.H.
V.C.
0-10V
0-10V
0-10V +24V
GND 0-10V 24V
GND
24V
GND
24V
+24V
RC
IN/OUT
GND
Tsens 1
CONTROL PANEL
I2C
RS485 A/B
CO2
PC / RF
THERMOSTATE 1
DIPSWITCH
Tsens 2
Tsens 3
Tsens 4
JAGA
1
2
3
4
5
6
7
8
ON
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
N L
15120045
GND
GND
GND
GND
NTC1
V.H.
V.C.
0-10V
0-10V
0-10V +24V
GND 0-10V 24V
GND
24V
GND
24V
+24V
RC
IN/OUT
GND
Tsens 1
I2C
RS485 A/B
CO2
PC / RF
Tsens 2
Tsens 3
Tsens 4
1
2
3
4
ON
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
N L
15120045
GND
GND
GND
GND
NTC1
V.H.
V.C.
0-10V
0-10V
0-10V +24V
GND 0-10V 24V
GND
24V
GND
24V
+24V
RC
IN/OUT
GND
Tsens 1
CONTROL PANEL
I2C
RS485 A/B
CO2
PC / RF
THERMOSTATE 1
DIPSWITCH
Tsens 2
Tsens 3
Tsens 4
JAGA
1
2
3
4
5
6
7
8
ON
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
N L
15120045
GND
GND
GND
GND
NTC1
V.H.
V.C.
0-10V
0-10V
0-10V +24V
GND 0-10V 24V
GND
24V
GND
24V
+24V
RC
IN/OUT
GND
Tsens 1
I2C
RS485 A/B
CO2
PC / RF
Tsens 2
Tsens 3
Tsens 4
1
2
3
4
ON
Summary of Contents for BRIZA 12 PLUG & PLAY
Page 1: ...BRIZA 12 PLUG PLAY MANU L ANLEITUNG MANUAL...
Page 59: ...NOTA...