H 9 6 5 8 5 1
Three Hole Bidet Set
with Vacuum Breaker
SMALL
END
LARGE
END
LARGE
END
VALVE
OUTLET
VALVE
OUTLET
PUTTY
1
2
3
INSTALL SUPPLY HOSES
INSTALL SPRAY BODY
Connect small end of SUPPLY HOSES
(1)
TO "Y" ADAPTER
(2)
and larger end to each VALVE OUTLET.
Important: Loop SUPPLY HOSES
(1)
as illustrated
so they do not kink.
Connect one end of SPRAY HOSE
(7)
to HOSE ADAPTER
(8)
and the other end to shank of SPRAY BODY
(3)
. Tighten
hose connections to make a water tight seal.
JAD
O
JAD
O
1
Apply putty to the underside of SPRAY BODY
FLANGE
(3)
and install SPRAY BODY
(3)
into
spray hole of Bidet.
From underside of Bidet install RUBBER WASHER
(4)
,
FIBER WASHER
(5)
and LOCKNUT
(6)
onto shank of
SPRAY BODY
(3)
. Tighten LOCKNUT
(6)
to make water
tight seal.
4
8
5
6
7
7
9
9a
HOT
FRONT
COLD
Connect HOT water supply to inlet of left SHANK and COLD water supply to right
SHANK using sealant, appropriate connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
10
Connect water supply to VALVE BODIES
(9,9a)
with
1/2" IPS FLEXIBLE SUPPLIES
(10)
or 3/8" O.D. BULL-NOSE
RISERS
(11)
. Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS
NOT INCLUDED AND MUST BE PURCHASED SEPARATELY.
FERRULE
COMPRESSION
NUT
COUPLING NUT
FLEXIBLE
SUPPLIES
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
THREAD
3/8 COMPRESSION
CONNECTION
CONNECT TO
WASTE OUTLET
10
11
POP-UP KNOB
(1)
must be fully
down.
Fig.
A.
Thread CABLE CONNECTOR
(1)
clockwise onto DRAIN BODY
CONNECTION
(2)
and hand
tighten.
Fig.
B.
Your new POP-UP DRAIN
installation is now complete.
Fig.
C.
Note:
Tailpeice on pop-up drain
is 1-1/4” O.D.
Fig.
C.
Fig.
B.
ATTACH CABLE
CONNECTOR
8
Operate LIFT KNOB
(1)
to verify that STOPPER
(2)
opens and closes.
Note:
If STOPPER
(2)
does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
CHECK OPERATION OF POP-UP
INSTALL DIVERTER KNOB
9
Fig.
C.
1-1/4” O.D.
1
3
1
1
2
2
WATER SUPPLY CONNECTION
4
2
3
DOWN
Fig.
A.
For Diverter handle:
Install DIVERTER HANDLE
(1)
onto VALVE STEM
(2)
of DIVERTER.
Secure with DIVERTER HANDLE SCREW
(3)
.
Thread HANDLE CAP
(4)
onto DIVERTER HANDLE
(1)
.