3/4" Thermostatic Mixing
Valve Trim Kit

Phillips Screwdriver

RECOMMENDED TOOLS 

Regular Screwdriver

TEMPERATURE CALIBRATION

1

Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.

Check that arrow marking B points vertically upwards. If not, push
the BLACK CLAMP on the SECURING RING to the right, pull off KNOB
MOUNT and reinstall KNOB MOUNT with arrow "B" pointing upwards.

For 100

°

 F adjustment, turn the water supply on. Turn KNOB

MOUNT until the spout temperature is 100

°

 F. Check that arrow

marking A on the KNOB MOUNT still points upward after adjusting
the thermostat to 100

°

 F.  If not, pull out the RED LOCKING DEVICE.

Remove KNOB MOUNT by pulling it towards you while standing directly
in front of the valve.

Reinstall the KNOB MOUNT so that the arrow marking A points upwards.

The maximum mixed water temperature is set at 109

°

 F at the

factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic
part). Re-install it at the desired notch as indicated in the diagram
to limit the maximum mixed water temperature to 104

°

F or 112

°

F.

Reinstall RED LOCKING DEVICE. 

KNOB 

MOUNT

ARROW

"A"

BLACK

CLAMP

ARROW

"B"

RED LOCKING

DEVICE

SECURING

RING

104

°

109

°

112

°

TEMPERATURE

LIMIT STOP

ROUGHING-IN DIMENSIONS

FINISHED

FLOOR

FINISHED

WALL

1-11/16"

TO

2-1/2"

(42mm TO 

64mm)

3/4" NPT OUTLETS

(19mm)

3/4" NPT INLETS

(19 mm)

5-7/8"

(149mm)

CL

48" TO 54"

FOR SHOWER ONLY

(OPTIONAL)

(1219mm TO 1372mm)

32" TO 42"

FOR BATH/SHOWER

AND BATH FILLER

(OPTIONAL)

(813mm TO 1067mm)

7-3/16"

(182.5mm)

3-3/8"

(86mm)

For reference