background image

 

Content 

Introduction ........................................................................................................ 3

 

Components ...................................................................................................... 3

 

Chapter 1: JDI-800 Introduction ......................................................................... 5

 

Product Introduction ........................................................................................... 5

 

Chapter 2: Installation ........................................................................................ 6

 

Installation Introduction ...................................................................................... 6

 

Chapter 2: Operation ....................................................................................... 10

 

Basic Introduction ............................................................................................ 10

 

Keys: ......................................................................................................... 10

 

Capacity Setting and Calibration ............................................................... 10

 

WEIGHT FUNCTION ................................................................................ 15

 

TARE FUNCTION ..................................................................................... 16

 

PRETARE FUNCTION .............................................................................. 17

 

GROSS/NET WEIGHT FUNCTION .......................................................... 18

 

AUTO TARE FUNCTION: ......................................................................... 19

 

WEIGHT CK ............................................................................................. 20

 

ACCUMULATION SET ............................................................................. 21

 

Serial Number Setting: .............................................................................. 23

 

Dual Scale Switch: .................................................................................... 24

 

Dual Scale Display: ................................................................................... 24

 

SAMPLE ................................................................................................... 25

 

Unit Weight, Store UW, UW Lookup: ........................................................ 27

 

Clear Count: .............................................................................................. 29

 

Quantity Check: ........................................................................................ 29

 

Chapter 4

Scale Setup .................................................................................. 30

 

  Parameter setting ........................................................................................... 30

 

Weight CK ................................................................................................. 31

 

QYT CK .................................................................................................... 32

 

Auto Tare .................................................................................................. 33

 

Serial Set: ................................................................................................. 33

 

UnitsSet .................................................................................................... 34

 

Acc Set ..................................................................................................... 34

 

CommPort................................................................................................. 35

 

SW Setting ................................................................................................ 36

 

Accuracy ................................................................................................... 37

 

Zero Range ............................................................................................... 37

 

FilterSet .................................................................................................... 38

 

Stable level ............................................................................................... 38

 

Minus value print ....................................................................................... 38

 

ACC ToZero .............................................................................................. 39

 

Weight recording ....................................................................................... 39

 

Summary of Contents for JDI-800

Page 1: ...N 17 GROSS NET WEIGHT FUNCTION 18 AUTO TARE FUNCTION 19 WEIGHT CK 20 ACCUMULATION SET 21 Serial Number Setting 23 Dual Scale Switch 24 Dual Scale Display 24 SAMPLE 25 Unit Weight Store UW UW Lookup 27 Clear Count 29 Quantity Check 29 Chapter 4 Scale Setup 30 Parameter setting 30 Weight CK 31 QYT CK 32 Auto Tare 33 Serial Set 33 UnitsSet 34 Acc Set 34 CommPort 35 SW Setting 36 Accuracy 37 Zero Rang...

Page 2: ...to off 44 Sound 44 Manual Update 45 Theme 45 Language 45 Time 46 AutoSleep 46 Setting password 47 Chapter 7 Printing Label Setting 47 Label Edit 47 New Label 47 Edit 48 Input designed label into printer 50 Chapter 8 Advanced Applications 51 Expanding Usage 51 Material system 51 System Initialization 51 Touch screen adjustment 51 Error message and troubleshooting 53 ...

Page 3: ...d to read this manual in full before using it for good function application Components Front Sides 1 7 inches Touch screen 2 Zero button 3 Tare button 4 Gross Net button 5 Sleep Wake button 6 On Off 7 Power light Left Side 1 Audio output interface 2 Audio input interface 3 RJ45 interface 2 3 4 5 6 7 1 1 2 3 ...

Page 4: ...JADEVER 4 Right Side 1 USB interface 2 RS 232 interface 3 RS 232 interface Back Side 1 load cell interface for Scale 1 2 load cell interface for Scale 2 3 stylus 1 2 3 3 1 2 ...

Page 5: ...io interface Power Supply 6V 2 5A Rechargeable battery optional Feature Touch screen together with 5 keys operation Multiple theme options intuitive menu operation in Chinese English and Spanish with weighing speak Settable label with multiple templates Come with auto inventory management software Powerful storage space and system expansivity Cable and wireless network connection Dual channel Mult...

Page 6: ...but less than maximum capacity Weighing Inspection Turn on the weighing inspection function lower than min unit weight The unit weight is less than 0 8e of division insufficient sampling data Enter the sample quantity and make it less than 10 Counting Inspection Turn on the counting inspection function JOW signal Turn on the wireless module device U disk mark U disk is dected Wi Fi signal Wireless...

Page 7: ...d sudden temperature changes suitable operating temperature is between 0 40 Disconnect the power supply before cleaning the indicator Don t immerse the indicator in water or other liquids Service should be performed by authorized personnel only Package The package should contain JDI indicator Adaptor U disk User manual Power Supply Adapter Input 100 240 50 60Hz 800mA Output DC 6 0V 2 5A Load Cell ...

Page 8: ... with BP545D DODEX ZEBRA Printer 2 Connection with SH 24 Printer 3 Connection with PC 1 Using the cable shown in the following picture to connect the PC and Indicator 2 Set the printing mode to CONTINUE 3 Ensure there is receive program in the PC ...

Page 9: ...er Universal 25 pin male to 25 pin female connecting cable Note The hollow dots represent male connectors and the black dots represents female connectors Note The hollow dots represent male connectors and the black dots represent female connectors ...

Page 10: ... mode 3 GROSS NET Key Toggles between gross and net weight 4 SLEEP WAKE Key Toggles between standby mode and working mode 5 I O Key Power on or off the scale Capacity Setting and Calibration Capacity and Resolution 1 Press Key SETUP Set Weight Advanced Param Accuracy you will see the following screen Note Scale will turn black when download data at the beginning of power on the scale ...

Page 11: ...on screen and pls press Return if you don t need to calibrate scale Calibration I Press SETUP CAL you will enter the calibration screen Or you could calibrate scale once finishing the Accuracy and Max CAP setting There are two Calibration method as following Note You could set different units for Scale1 and Scale2 ...

Page 12: ...l show 2 The screen will enter the first point calibration setting screen after finishing the zero point calibration Please enter the calibration value by numeric key and press OK for example enter 1kg the unit should corresponds the unit set before then press OK 3 Please put 1kg weight on the weighing pan ...

Page 13: ...uld press Return to finish calibration or go on STEP 6 6 Put additional 2kg weight on the weighing pan the screen will show 3kg and finish the first point calibration as following Repeat the STEP 6 to continue several points calibration n3 on4 and on5 7 Then press Return to finish calibration steps Calibration method II 1 Pleas pressCal Setupto enter the calibration method II ...

Page 14: ...eed to change the CAL value pls double click the value you need to change in the left screen to make the value show on message box of the Current CAL value then enter the value you need and press OK the left screen value will change according to your setting 4 Press OK to return the calibration screen then pressMulti point to continue the calibration ...

Page 15: ...carry out Multi point calibration and the screen will show Calibrate OK when finish calibration of each point The screen will back to the calibration screen when finish all points of calibration WEIGHT FUNCTION WEIGHT PressWEIGHTon the main screen and put weight on the weighing pan ...

Page 16: ...JADEVER 16 TARE FUNCTION 1 Put the container on the weighing pan and when the screen show stable icon pressTARE 2 Then put weight in the container the screen will show the net weight of weight ...

Page 17: ... weight of container 4 Please Press TARE again after cleaning the weighing pan to cancel tare PRETARE FUNCTION 1 Enter the weighing screen and hold on TARE for 3 second and enter the pre tare value as following 2 PressOK to save value 10g for example and back to weighing screen ...

Page 18: ... screen will show the net weight of weight 4 Please Press TARE again after cleaning the weighing pan to cancel tare GROSS NET WEIGHT FUNCTION 1 Put the container on the weighing pan and pressTARE when the stable icon appear 2 Press GROSS NET to switch gross net weight ...

Page 19: ...et weight condition then pressTARE to cancel tare AUTO TARE FUNCTION 1 Press SETUP Set Weight General Param Auto Tare 2 Enter the Max Tare and Min Tare value for example 3 Active the Auto tare function ON function and enter the weighing or counting mode screen ...

Page 20: ...tting range the scale will tare automatically as following 5 Clean the weighing pan the tare will be cancelled automatically WEIGHT CK 1 Press SETUP Set Weight General Param Weight CK Note there is icon and the TARE value will become zero ...

Page 21: ...mode Beep in for example and active Check weighing function ON 3 Press OK to save the setting 4 Back to the weighing screen and put the weight on the weighing pan then the screen will show the High Low OK weighing condition ACCUMULATION SET Accumulation 1 Press SETUP Set Weight General Param AccSet ...

Page 22: ...tting 3 Back to the weighing screen and put the weight then press M to accumulate data Show Accumulation data Press MR to check all accumulation data if it is needed Export Connect U disk and press Export to save the data to U disk DelOne Please choose the item you need to delete and press DelOne to delete it ...

Page 23: ...cel Last Next Use these button to check the data page by page Serial Number Setting 1 Press SETUP Set Weight General Param SerialSet 2 Enter the Current SN Max SN the SN increase way and so on for example Weighing SN Manual ACC as following 3 Press OK to active SN function and enter the weighing screen you will see ...

Page 24: ...er 4 Put weight on the pan and the weight data is stable then press SN ACC the ACC number will increase one by one Dual Scale Switch Connect Scale 1 and 2 you could see or on the top left sidefor switch scales Dual Scale Display ...

Page 25: ... Dual the weighing data of two platforms will appear in the screen at the same time COUNTING FUNCTION SAMPLE 1 Press COUNTING and enter the normal counting mode Note Counting and Weighing mode share same function of tare pre tare auto tare Weigh CK ACC SN and Dual channel ...

Page 26: ...itional sample to get a more accurate unit weight For example take a sample quantity as 10 first time and get a unit weight then you could add more sample the additional sample should less than total quantity to get a more accurate unit weight Repeat the sample modification in order to get a more accurate unit weight 5 ACAI is activated once input a sample quantity and hold on SAMPLE button to dis...

Page 27: ...t 1 Press COUTING button and enter the counting mode 2 Press UW to input the unit weight 3 Press OK after enter the UW and return the counting mode 4 Put the weight and count automatically Store UW 1 Put the weight and get a unit weight under the counting mode ...

Page 28: ...n 3 Press OK to save the unit weight and return the normal counting mode UW Lookup 1 Enter the counting mode and press UW Lookup Export Press this button to export the data to U disk Modify Choose the needed ID item and press Modify to alter the info of this UW record ...

Page 29: ...ting mode 2 Choose the needed ID item and press OK to enter the normal counting mode Clear Count If there is U W data or COUNT data press Clear Count to delete the UW data and COUNT data Quantity Check 1 Press SETUP Set Weight General Param QYT CK 2 Enter the upper and lower limit and choose the alarming mode for example Beep in and active the Quantity check function ON ...

Page 30: ...imit 5 OK indication appears when the item on the weighing pan is between upper and lower limits 6 Low indication appears when the item on the weighing pan is smaller than lower limit Note the item on the weighing pan should be more than or equal to 20e Chapter 4 Scale Setup Parameter setting Press SETUP and Set Weight to enter General Param or Advanced Param ...

Page 31: ...han the lower limit Beep in There is beep when the item on the weighing pan is between upper and lower limits Beep out There is beep when the item on the weighing pan is smaller than the lower limit or greater than the upper limit Note the item on the weighing pan should be more than or equal to 20e Unit Weight Save and Calling out 1 Press Save Record to save the upper lower limit setting and ente...

Page 32: ... to save record up to 50 pcs 3 Press Record Recall to choose the upper lower limit setting record needed Press Last and Next to choose the item needed or enter the page number directly to check the item list as following 5 Press the need item No and press OK or press Exit to return last level QYT CK ...

Page 33: ...g pan is between upper and lower limits Beep out There is beep when the item on the weighing pan is smaller than the lower limit or greater than the upper limit Note the item on the weighing pan should be more than or equal to 20e Auto Tare Activate or Disable this function Serial Set Weight CK and QYT CK have the same function in Save Record and Record Recall Auto Tare and QYT CK have the same fu...

Page 34: ...n HI LO checking limits Count OK ACC Serial number plus 1 1 or minus 1 1 when the weight is in between HI LO checking limits Manual ACC Serial number plus 1 1 or minus 1 1 when press SN ACC Weighing SN Activate Serial number function under weighing mode Counting SN Activate Serial number function under counting mode UnitsSet Option g kg lb oz tl hl t Acc Set Note Max Serial number up to 99999 pcs ...

Page 35: ...K range Count OK ACC Accumulate when the count is within the HI LO range OK range Manual Accumulate manually by pressing CommPort Optional external devices Printer Choose the RS 232 port needed Press Set to choose the printer and the printing mode The printer GODEX ZEBRA BP545D SH 24 The printing mode Manual Stable Print after OK Note the max ACC number up to 20000 ...

Page 36: ...isplay Scale software Press Set to choose its sending mode Manual send Stable Continuous Wireless LC JOW wireless module optional SW Setting The max single weight number up to 50 pcs Advanced Param Press SETUP Set Weight Advanced Param ...

Page 37: ...acity setting and the unit switch Zero Range Choose the zero range rank D0 D1 D2 D3 D4 D5 according to the actual using surrounding D0 Zero point indication appears when variation is 0e D1 D5 Zero point indication appears when variation is 1e 2e 5e ...

Page 38: ...on L1 the good working condition with best performance L2 the relatively stable working condition L3 the common working condition L4 the unstable working condition with the slower reaction L5 the vibrative working condition Stable level Select the stable level as Rapid Middle and Slow to set the condition for appearance of stable indication Minus value print ...

Page 39: ...able minus value print To enable or disable minus value print ACC ToZero Set whether to accumulate after the display goes back to zero Yes Accumulate after return to zero No Accumulate without returning to zero Weight recording ...

Page 40: ...ng data Yes Turn off and turn on the scale the scale will show the last weighing data Trans speed Choose the data transmission speed of scale when worked with weighing management software AD Gain Rapid Suitable to low resolution scale Slow Suitable to high resolution scale JOW Param ...

Page 41: ...ommunication distance JOW Spare and press OK to save parameter Units choose the unit needed and press OK to save parameter Chapter 5 Network Setting Network Press SETUP Network there are two choice for network EthNet and WifiConn Cable Network ...

Page 42: ...MAC Address directly or Activate the function of Auto get IP to connect network 3 Press OK to save setting and connect the network Wifi Connection 1 Press WifiConn to set the wifi connection 2 Then insert the WLAN card and press SearchNetwork after identification Note MAC Address use decimal system ...

Page 43: ...ss OK to connect the wifi network 5 The screen will show the following screen after connecting the network successfully 6 Press WifiSet to enter the IP Netmak and Gatewayor activiate Auto get IP to connect the wifi network as following 7 Press DisconnNetwork to disconnect the network anytime needed ...

Page 44: ...JADEVER 44 Chapter 6 System Setting System Setting Press SETUP System Set Auto off Sets the period of inactivity the weight is less than 9d of gross weight before the scale automatically turns off Sound ...

Page 45: ... be updated by simply pressing Manual Update button Note If the system cannot identify the U disk please restart the scale and use another U disk U disk cannot be used together with Wifi network card Theme Press to select your favor theme blue style for default Language Note It is prohibit changing the file name of JDI after copy to the U disk and should save this file to the root directory Note T...

Page 46: ...e time of system according to the local time AutoSleep Set the period of inactivity before the scale automatically turns to standby mode Note The way to wake up the scale Press key Sleep Wake Click the screen Note The system will restart automatically after choose a new language ...

Page 47: ...ng password Set a password Chapter 7 Printing Label Setting Label Edit Press SETUP Set Label the screen shows folloing New Label 1 Press to create a new label and enter the size needed and press OK to save the setting ...

Page 48: ... name label name and press Enter to save the name of label and go to the label edit Edit Press to go to the edit screen directly but you also have to enter the label size firstly as following Then press OK to enter the edit screen ...

Page 49: ...rward Open the file Save as another file Enter Exit Input designed label into scale Output label Hold the selected item and add other items being selected Undo current operation Edit New Label Text adjustment Label adjustment 1 Settable bar code with 6 printing style and 13 parameter optional 2 The date and time on the label is based on the scale time setting 3 Readable bar code printing yes or no...

Page 50: ...nt and Input designed label into printer Printing copies settable Printing direction forward and reverse Printer mode GODEX ZEBRA BP545D or SH 24 10 Add Text Press and enter length the unit of length is mm or the default length is 10mm 11 Label lookup Press to open the label and enter the label name or the initial letter of its name on the top right to search Input designed label into printer 1 Ch...

Page 51: ...er 5 4 Press STOCK in the JDI main screen and enter the UserName 123456 Password 123456 and Server IP Press ENTER to connect 5 There is message to show the set up status System Initialization If there is system failure after update please initial the parameter Press and hold key ZERO while powering on the scale Do not release it unless there is a beep sound which means the initialization is finish...

Page 52: ...ile pressing down ZERO key to start screen calibration During the procedure press Sleep Wake key to wake up the device if it enters the standby mode 2 The icon will disapear once the screen calibration is finished 3 Then press the touch screen to return the main screen ...

Page 53: ...e Scale capacity and calibration needed Set the capacity of scale and calibrate it Overspill Can t enter the weighing or counting mode 1 Recalibrate 2 Ensure to empty the weighing pan Error Serial number or accumulation function error Check if the current SN is larger than the Max number ...