Low battery indication 

Tare or Preset Tare Indication

       

Center of Zero Indication, The zeroing range is 

 

Auxiliary display (parameter, accumulated number of weighments)

TARE 

Symbol “   ” points at 

“TARE” 

Preset Tare. 

Symbol “   ” points at 

NET” 

Net weight

--

Gross weight minus 

Tare or preset are actions are done.

“UW” 

Under simple counting mode, Symbol “ ” poi

is  lower  than  4/5  of  scale  division.  Unit  weight  is  too  small  for  ensuring  accurate  quantity 
calculations. 

  

Units of measure 

  

The weight on the weighing pan is greater than the upper

  

The weight on the weighing pan is between upper and

  

The weight on the weighing pan is smaller than lower

 

  

Stable indication 

  

Charge Lamp 

Red--- battery is charging 

Green---battery is fully charged 

 

  Keyboard 

 

 

UNIT/LO 

key 

 

Short press steps through activated weigh units and release on desired

 

Long press lower limit initials lower limit

 

Shift key( shift leftwards) 

www.cangiaphat.com

Tare or Preset Tare Indication 

Center of Zero Indication, The zeroing range is ±2

of weighing capacity.

Auxiliary display (parameter, accumulated number of weighments) 

“TARE” 

when manual Tare action is done. 

Symbol “   ” points at 

“Preset Tare” 

when preset tare value is set.

Gross weight minus Tare.  Symbol “        ” points at 

“NET”

or preset are actions are done. 

Under simple counting mode, Symbol “ ” points at “

UW” 

when calculated unit weight  

is  lower  than  4/5  of  scale  division.  Unit  weight  is  too  small  for  ensuring  accurate  quantity 

The weight on the weighing pan is greater than the upper limit. 
The weight on the weighing pan is between upper and lower limits. 
The weight on the weighing pan is smaller than lower limit. 

Short press steps through activated weigh units and release on desired
Long press lower limit initials lower limit setting 

 

www.cangiaphat.com

capacity. 

 

when preset tare value is set. 

“NET” 

when  manual 

when calculated unit weight  

is  lower  than  4/5  of  scale  division.  Unit  weight  is  too  small  for  ensuring  accurate  quantity 

Short press steps through activated weigh units and release on desired unit 

Summary of Contents for 1.5K

Page 1: ...www cangiaphat com ...

Page 2: ... 2 Display 4 3 Keyboard 4 4 Power Supply 2 3 4 4 5 Operation 5 1 Weighing 5 2 Manual Tare Preset Tare 5 3 Checkweighing 5 4 Simple Counting 5 5 Accumulation Accumulation Display and Accumulation Clearing 5 6 Unit setting menu 4 5 5 6 6 6 6 Calibration 6 1 Single Point Calibration 6 2 Linear Calibration 7 7 7 Setting Mode Description of Parameter Values 8 Serial Interface 8 1 RS 232 Connector 8 2 S...

Page 3: ...ould be performed by authorized personnel only 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediately inform your dealer if you have complaints or if parts are missing The package should contain Scale body Weighing platform plastic base with stainless steel pan Power cord User manual Installing Components 1 Before using the ...

Page 4: ...f low battery and charging status indication Multiple functions tare preset tare simple counting checkweighing and Accumulation Single point calibration and linear calibration available CE type approved Display Model 1 5K 3K 6K 7 5K 15K 30K Capacity Kg 1 5 3 6 7 5 15 30 Division 1 g 0 5 1 2 2 5 10 Division 2 g 0 2 0 5 1 1 2 5 Division 3 g 0 1 0 2 0 5 0 5 1 2 Division 4 g 0 05 0 1 0 2 0 2 0 5 1 Dis...

Page 5: ...Tare or Preset Tare Indication Center of Zero Indication The zeroing range is 2 of weighing capacity Auxiliary display parameter accumulated number of weighments TARE when manual Tare action is done Symbol points at Preset Tare when preset tare value is set Gross weight minus Tare Symbol points at NET or preset are actions are done Under simple counting mode Symbol points at UW when calculated uni...

Page 6: ...d tare entrie M key Adds the indicated weight into Accumulation memory During editing selects the next higher option or increases setting values M key Deletes accumulation records During editing selects the next lower option or decreases setting values ZERO ESC key Zeros the display within 2 of max capacity Exits from setting mode Power Supply Please verify the local AC power source and switch the...

Page 7: ...that must be held in a container tare stores the container weight into memory Manual Tare 1 Under the weighing mode place the container on the weighing pan wait tillstable symbol appears and press the key TARE The container is tared 2 Place the item s to be weighed into the container The weight displayed is the net weight 3 Remove all items from the weighing pan the screen displays the tare value ...

Page 8: ...ainer to display gross and net weight by turns Use this mode to compare the weight of an item to Lower and Upper limits When the checkweigh mode is enabled the indicator will turn on Began by pressing down key UNIT LO for 3 seconds The scale is now in most digit to increase setting values key M to decrease setting value to shift leftwards and key PRINT HI toshift save the Lower limit and return to...

Page 9: ...samples and put the load on the scale begins to count The larger the sample size the more accurate unit weight Symbol points at UW when calculated unit weight is lower than 4 5 of scale Accumulation Accumulation Display and AccumulationClearing Under the weighing mode put the item on the weighing pan Press key is displayed momentarily before the display reverts Remove the item and the display goes...

Page 10: ...t is turned on Press key M to set whether to retain the last set weight unit when the unit is turned on then press key G N to save and return to normal weighing mode Last used weight unit is retained when the unit is turned on Last used weight unit is not retained when the unit is turned on Note if enter the Unit setting menu by method 2 press key G N to save and then press key ZERO ESC to return ...

Page 11: ...d on the weighing pan E g for JWL The calibration procedure ends up with a symbol of Remove all the weights and then press key TARE to return to weighing mode while powering on the scale The screen displays to enter the zero point calibration appears with the right most digit blinking press key to shift rightwards key M to increase setting values and value Put the corresponding weights on the weig...

Page 12: ... are Aut 10 Aut 30 Aut 60 and Aut 90 minutes P01 Set Check Weighing buzzer beep Options are B UP B in B out and b There will be a warning sound when the material s weight exceeds the preset upper There will be a warning sound when the material s weight is between the upper and There will be a warning sound when the material s weight exceeds the preset upper and lower limits and the exceeding weigh...

Page 13: ... 1 division Zero 1 2divisions Zero 2 3divisions Zero 3 4 divisons Zero 4 5divisions and Zero 5 6divisions 11 P10 Initial Setup not available 12 P11 Unit setting refer to section 5 6 8 Serial Interface If external interface is needed please select the proper three in one board first which integrates RTC time display RS 232 and relay weight checking functional module onto one circuit board Only afte...

Page 14: ...contact Service E05 out ran Overload condition Remove weight that is greater than the scale capacity from the pan E07 E Lo Hi The weight checking upper limit value is less than the lower limit value Reset the upper limit value E08 CK UNIT The unit set for weight checking is different from the current unit Disable weight checking function or reset HI LO value EU nit improper accumulation unit Retur...

Reviews: