background image

 

P/N 24-156 REV A 7/00 

 

Page 3 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FOR FUTURE REFERENCE  

TO OPERATOR, INSTALLER, USER 

 
 

IT IS NECESSARY TO REGISTER MODEL NUMBER 

AND SERIAL NUMBER FOR WARRANTY SERVICE. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

WHERE CAN YOU FIND MODEL NUMBER AND SERIAL NUMBER? 

(LOCATION OF NAMEPLATE) 

 
 
 
 
 
 
 

Insert -- DIAGRAM CONVECTION OVEN 

 
 
 
 
 
 

FUTURE OVEN INFORMATION 

 

STOP 

 

STOP 

 

STOP 

MODEL # 

MODEL # 

MODEL # 

Summary of Contents for CONVECTION OVEN

Page 1: ...OUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance c...

Page 2: ...AND HEAT FLOW 6 COOK ONLY OVEN CONTROLS 13 OVEN OPERATIONS 14 COOK HOLD OVEN CONTROLS 15 OVEN OPERATIONS 16 GENERAL GUIDELINES 19 CLEANING AND PREVENTIVE MAINTENANCE 19 MAINTENANCE INSTRUCTIONS ADJUST...

Page 3: ...TOR INSTALLER USER IT IS NECESSARY TO REGISTER MODEL NUMBER AND SERIAL NUMBER FOR WARRANTY SERVICE WHERE CAN YOU FIND MODEL NUMBER AND SERIAL NUMBER LOCATION OF NAMEPLATE Insert DIAGRAM CONVECTION OVE...

Page 4: ...ional Fuel Gas Code ANSIZ223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code CAN CGA B149 2 as a applicable including 1 The appliance and its individual shutoff valve m...

Page 5: ...SUFFERED IN TRANSIT LOCATION OR PLACEMENT OF OVENS MUST BE AS FOLLOWS FREE OR DRAFT ACCESSIBLE FOR PROPER OPERATION AND SERVICING ALLOW MINIMUM OF 3 FEET FROM THE FRONT OF THE APPLIANCE FREE AND CLEA...

Page 6: ...P N 24 156 REV A 7 00 Page 6 INSERT PICTURE CONVECTION OVEN...

Page 7: ...T HEAT HEAT CLEARANCES INSTALLATION 1 For installation in fire resistant locations only 2 For installation with the following minimum clearances to combustible clearances Sides 6 inches Back 3 inches...

Page 8: ...three prong receptacle Do not cut or remove the grounding prong from this plug Picture of power supply cord Picture of 3 prong receptacle NOTE A WIRING DIAGRAM IS LOCATED INSIDE THE CONTROL COVER This...

Page 9: ...a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use with Gas Fuel ANSIZ21 41 OR Quick Disconnect Devices for Use with Gas Fuel CAN1 6 9 to limit the movement...

Page 10: ...s unsatisfactory baking results and possible premature failure of burner components Two methods acceptable for ventilation Mechanically driven canopy type exhaust hood Direct flue arrangement In direc...

Page 11: ...P N 24 156 REV A 7 00 Page 11 Insert PICTURE MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS...

Page 12: ...ARANCE IN THE BACK OF THE OVEN WILL RESULT IN OPERATIONAL PROBLEMS AND WILL SHORTEN LIFE OF THE BLOWER MAINTAIN MINIMUM CLEARANCE IN THE BACK OF THE OVEN DO NOT OBSTRUCT VENTILATION Insert PICTURES NO...

Page 13: ...GRAM TEST FOR LEAKAGE To check for leaks use a commercial leak detecting solution or soap suds DO NOT USE OPEN FLAME TO DETECT GAS LEAK CONVERSION NATURAL PROPANE BURNER ORIFICE NATURAL PROPANE LP 47...

Page 14: ...position the blower stops when the door is open 3 SPEED SWITCH controls speed of the motor HI speed Low speed 4 LIGHT SWITCH controls interior lights 5 THE COOK THERMOSTAT controls temperature when o...

Page 15: ...RESS BLOWER SWITCH TO AUTOMATIC DO NOT OPERATE OVEN WITHOUT BLOWER FOR MORE THAN 3 MINUTES 4 IF PILOT IS EXTINGUISHED TURN THERMOSTAT TO OFF POSITION AND WAIT 5 MINUTES REPEAT INSTRUCTIONS 1 THRU 3 5...

Page 16: ...4 SET COOK THERMOSTAT 5 TO THE DESIRED BAKING OR ROASTING TEMPERATURE 5 PREHEAT OVEN UNTIL INDICATOR LIGHT 6 GOES OFF INDICATING OVEN HAS REACHED PRE SET TEMPERATURE 6 LOAD PRODUCT IN OVEN DETERMINE C...

Page 17: ...imes When in AUTO position the blower stops when the door is opened 3 SPEED SWITCH controls speed of the motor HI speed Low speed 4 LIGHT SWITCH controls interior lights 5 START STOP SWITCH Used to St...

Page 18: ...eat temperature The display will alternate between PrE and probe temp 2 When the oven temp reaches the desired pre heat temp the control will enter a pause mode with the CYCLE ON light flashing and a...

Page 19: ...n Models OC100 OC102 fan is on continuously during cook mode and only when heater output is on during hold mode On Models OC101 OC103 fan is on continuously during cook and hold modes C Operation Remo...

Page 20: ...k direction 3 tighten door hinge bolts securely PICTURE REMOVAL AND REPLACEMENT WARNING BEFORE ANY REPAIRS OR SERVICE TURN OFF GAS AND ELECTRICAL SUPPLY ACCESS PANELS 1 DOOR MECHANISM COVER Loosen two...

Page 21: ...P N 24 156 REV A 7 00 Page 21...

Page 22: ...D TIME WHENEVER THE POWER IS RESTORED WHEN AN APPLIANCE IS ON CASTERS AND IS CONNECTED TO THE SUPPLY PIPING BY MEANS OF A CONNECTOR THERE MUST BE A RESTRAINT ON THE UNIT IF THE REMOVAL OF THE RESTRAIN...

Page 23: ...4 MAKE SURE THERE IS GAS FLOW TO THE BURNER 5 ADJUST THE REGULATOR TO THE SETTING OF 5 W C FOR NATURAL GAS AND 10 W C FOR PROPANE GAS BY TURNING THE ADJUSTING SCREW IN THE REGULATOR STACK TO INCREASE...

Page 24: ...K AND BLOWER WHEEL REINSTALL BLOWER BAFFLE MAINTAIN MINIMUN 3 8 SPACE BETWEEN BLOWER WHEEL AND BLOWER BAFFLE TIGHTEN WINGNUTS DIAGRAM DIAGRAM BLOWER WHEEL BALANCE IS IMPORTANT BE VERY CAREFUL NOT TO D...

Page 25: ...FRONT OF OVEN REMOVE BLOWER BAFFLE AND BLOWER WHEEL SEE PAGE 21 REMOVE SIX OUTER SCREWS IN MOTOR MOUNTING PLATE AND PULL MOTOR OUT SLIGHTLY WITH CAUTION AS NOT TO DAMAGE WIRING CONDUIT CAREFULLY REAC...

Page 26: ...REV A 7 00 Page 26 CONTROL COVER After removing control cover swing CONTROL BOX PANEL forward Access to SWITCHES THERMOSTAT IGNITION BOX ELECTRICAL TERMINAL GAS SHUT OFF VALVE GAS VALVE UNION DIAGRAM...

Page 27: ...P N 24 156 REV A 7 00 Page 27 INSERT WIRING DIAGRAM WIRING DIAGRAM...

Reviews: