P/N 24-156 REV A 7/00
Page 4
NATURAL GAS
PROPANE GAS
US UNITS
SI UNITS
US UNITS
SI UNITS
GAS INLET
PRESSURE (at Manif.)
5” W.C.
1.25 kPa
10” W.C.
2.5 kPa
OVEN INPUT
PER BURNER
PER OVEN
20,000 BTU/hr
80,000 BTU/hr
5.9 kW
23.4 kW
20,000 BTU/hr
80,000 BTU/hr
5.9 kW
23.4 kW
MAIN OFFICE
ORIFICE SIZE
#47
#55
Installation must conform with local codes or in the absence of local codes, with the
National
Fuel Gas Code, ANSIZ223.1, Natural Gas Installation Code, CAN/CGA-B149/1, or the
Propane Installation Code, CAN/CGA-B149.2,
as a applicable, including:
1. The appliance and its individual shutoff valve must be disconnected form the gas supply
piping system during any pressure testing of that system at pressures in excess of ½ psig
(kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at
pressures equal to or less than psig (3.45 kPa)
GAS SPECIFICATION