Installation

English

Important Safety Instructions

This is a professional grade product. A working knowledge of construction techniques, plumbing and electrical installation 

according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor 

perform the installation of all Jacuzzi® products. Our warranty does not cover improper installation related problems.

READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS. 

Use this unit only for its intended use as 

described in this manual. Do not use attachments not recommended by the manufacturer. Never drop or insert any object 

into any opening.

  DANGER:

 

RISK OF ACCIDENTAL INJURY OR DROWNING!

 Do not permit children to use this unit unless 

they are closely supervised at all times. Do not use hydromassage bathtubs unless all suction guards are installed to 

prevent body and hair entrapment.

  DANGER:

 

RISK OF SEVERE INJURY FROM ELECTRIC SHOCK OR DEATH FROM ELECTROCUTION!

 

This unit must be connected only to a supply circuit that is protected by a 15 amp ground fault circuit interrupter (GFCI). 

Such a GFCI should be provided by the installer and should be tested on a routine basis. Follow the manufacturer’s 

instructions when testing the GFCI. The GFCI should interrupt power. Push the reset button. Power should be restored. 

If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without 

the test button being pushed, a ground current is flowing, indicating a possibility of an electric shock. Do not use this 

hydromassage bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a qualified service 

representative before using.

  DANGER:

 

RISK OF ELECTRIC SHOCK!

 Do not permit electrical appliances (such as a hair dryer, lamp, 

telephone, radio or television) within 60” (1524 mm) of this hydromassage bathtub. Connect only to a circuit protected by 

a ground fault circuit interrupter (GFCI). (For permanently connected units) A green colored terminal (or a wire connector) 

marked “G,” “GR,” “GROUND,” or GROUNDING”) is provided within the terminal compartment. To reduce the risk of 

electric shock, connect the terminal or connector to the grounding terminal of your electric service or supply panel with a 

conductor equivalent in size to the circuit conductors supplying the equipment.

  

WARNING

:

 

PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA!

 Hyperthermia occurs 

when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F 

(37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, 

drowsiness and fainting. Water temperature in excess of 104°F (40°C) may be injurious to your health. Check and adjust 

water temperature before use. The effects of hyperthermia include: 
A.  

Failure to perceive heat. 

B.  

Failure to recognize the need to exit the bath. 

C.  

Unawareness of impending hazard. 

D.  

Fetal damage in pregnant women. 

E.  

Physical inability to exit the bath. 

F.  

Unconsciousness resulting in danger of drowning.

  

DANGER!

 This equipment is intended for indoor use only. Install the equipment in accordance with these 

instructions. Use supply wires that are suitable for 167°F (75°C), including the temperature rating of the supply conduc-

tors to be used. This unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. 

Building materials and wiring should be routed away from the motor/pump or blower or other heat producing components 

of this unit. A pressure wire connector is provided on the exterior of the motor/pump and heater to permit connection of an 

No. 8 AWG solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the 

vicinity, as needed to comply with local requirements.

  

DANGER! 

RISK OF SEVERE INJURY OR DEATH!

 Risk of fetal injury. Pregnant or possibly pregnant women 

should consult a physician before using a hydromassage bathtub equipped with a heater.

  

DANGER! 

RISK OF SEVERE INJURY OR DROWNING! 

Keep body and hair a minimum of 6" (152 mm) away 

from the suction fitting at all times when the hydromassage system is in operation. Hair longer than shoulder length should 

be secured close to the head.

  

CAUTION!

 

Do not immerse the control panel by overfilling the bath.

Summary of Contents for Luxury Bath

Page 1: ...INSTALLATION INSTRUCTIONS LG32000 08 2015 Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino CA 91710 1 800 288 4002 www jacuzzi com...

Page 2: ...meowner Homeowner Read this manual and keep for future reference Product Information 2 Important Safety Instructions 3 Inspection and Testing 4 Framing and Support 5 Electrical Connections 6 Chromathe...

Page 3: ...OUND or GROUNDING is provided within the terminal compartment To reduce the risk of electric shock connect the terminal or connector to the grounding terminal of your electric service or supply panel...

Page 4: ...the product has been made Do not lift the bathtub by the plumbing at any time handle by the shell only 2 Inspect the shell and bathtub components Should inspection reveal any damage or defect in the f...

Page 5: ...ons use an integral molded three sided tiling flange bathtub When using the optional tile flange refer to instructions that are included with kit In remodeling if necessary add studs at each end to pr...

Page 6: ...t or splice of subfloor should be level to each other Electrical Connections DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a GFCI Figure 3 CAUTION Electrical outlet must be moun...

Page 7: ...be installed by a qualified plumber See special notes on freestanding section for faucetry Proper installation of the spout plumbing and compliance with local codes are the responsibility of the in st...

Page 8: ...If undermounting is an option be careful to select the guide lines that apply to the installation that you are performing 2 Complete all deck finish work and cover to protect from damaging while placi...

Page 9: ...dimensions square and plumb check floor for levelness Figure 10 Rough in should be kept to a minimum until the unit is on the job site Measurements may vary 0 or from original specifications 2 Place t...

Page 10: ...with applicable codes and generally accepted building practices 9 Turn on the power supply to the dedicated GFCI protected circuits and check system operation 10 Caulk around the perimeter of bathtub...

Page 11: ...the above locations have been marked on the floor remove the tub base skirt set it aside and continue with the installation process 4 Faucetry is not supplied with the freestanding bath To use deck mo...

Page 12: ...nce the whirlpool action intensifies the foaming properties of soaps The use of certain bathtub oils bubble baths and bathtub additives may increase the level of accumulations of bathtub residue in th...

Page 13: ...of the bathtub near the pump motor SPECIFICATION SERIAL NUMBER LABEL PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE USE TECHNICAL SPECIFICATIONS MANUAL SUPPLIED WITH PRODUCT Jacuzzi Luxur...

Page 14: ...e caused by the common carrier installer user or other per sons pets or rodents or resulting from without limitation any of the following careless handling lifting unit by plumbing abrading finish etc...

Page 15: ...ny replacement parts for the Options and Accessories Any replacement parts shall be covered by the original equipment manufacturer The Distributor or Dealer is responsible for knowing local code requi...

Page 16: ...Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino California 91710...

Page 17: ...y Installed 3 What was the main reason for purchase Styling Warranty Service Product Features Brand Name Price Hydrotherapy Home Resale________________________ Other______________________________ 4 Wh...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: