14
JAUTP / JAUTPS CONTROLLER
SECTION 7.
INSTALL SETTINGS
Install Settings is a hidden menu, mostly used for setup
and reference purposes.
Settings available through this menu:
• Freeze Protect
Automatically turn specific equipment on to protect
against freezing temperatures.
• Units
Change units of measurement displayed on the User
Interface (temperature and time format).
• Language
Change language displayed on the User Interface.
• Clear Memory
Clear all programmed data in the controller for all
equipment.
• Pump
Assign a one-speed, two-speed pump or variable-speed
pump to the controller.
• Color Lights
Only available if specific lights are installed in your
configuration.
• Label Aux
Assign custom labels to auxiliary equipment, such as an
air blower, cleaner, solar pump, etc.
• Temp Calibrate
Adjust temperature displayed on the User Interface up
or down by four (4) degrees.
• Solar Priority
Only available if solar heating is installed in your system.
• Assign JVA
Assign Jandy Valve
®
Actuators (JVAs) to specific AUX
relays, as intake or return in Pool Only mode.
• Ext. SWC Power
Only available if a salt water chlorinator (SWC) is
installed in your configurations.
• Assign Hotkeys
Only available if AquaPalm
™
is installed with your
configuration.
• Diagnostics
Display software revision information and alerts for
troubleshooting purposes.
To access the Install Settings Menu:
• Press and hold Up/Down arrow keys at the same
time for about 5 seconds.
12:40PM
Pool Mode
On
Pool Heater 80°F
Aux1 Off
Aux2 Off
Settings >
Devices >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory
>
Pump >
More
INSTALL SETTINGS
Color Light
>
Label Aux
>
Temp Calibrate >
Solar Priority >
Assign JVA
>
Assign Hotkeys >
INSTALL SETTINGS
Diagnostics >
12:40PM
Pool Mode
On
Pool Heater 80°F
Aux1 Off
Aux2 Off
Settings >
Devices >
INSTALL SETTINGS
Freeze Protect >
Units >
Language >
Clear Memory
>
Pump >
More
INSTALL SETTINGS
Color Light
>
Label Aux
>
Temp Calibrate >
Solar Priority >
Assign JVA
>
Assign Hotkeys >
INSTALL SETTINGS
Diagnostics >
7.1
FREEZE PROTECT
NOTE:
By factory default the filter pump cir
-
cuit is freeze protected. During freeze protec-
tion, the filter pump cannot be turned off.
IMPORTANT
Freeze protection is intended to protect equipment
and plumbing for short periods of freezing only. It does
this by activating the filtration pump and circulating the
water to prevent freeze inside equipment or plumbing.
Freeze protection does
not
guarantee that equipment
will not be damaged by extended periods of freezing
temperatures or power outages. In these conditions,
the pool and spa should be shut down completely (e.g.
drained of water and closed for the winter) until warmer
weather exists.
CAUTION
Activating the spa during freezing conditions will override
freeze protection. This means that if you are using your
spa when freezing conditions exist, freeze protection will
not
circulate water to non-spa related equipment that
you may have freeze protected (e.g. pool cleaner, booster
pump.) Under these circumstances, the potential for
equipment damage may exist.