background image

14

JAUTP / JAUTPS CONTROLLER

SECTION 7.   
INSTALL SETTINGS

Install Settings is a hidden menu, mostly used for setup 

and reference purposes. 

Settings available through this menu:

•  Freeze Protect 

Automatically turn specific equipment on to protect 
against freezing temperatures.

•  Units 

Change units of measurement displayed on the User 
Interface (temperature and time format).

•  Language 

Change language displayed on the User Interface.

•  Clear Memory 

Clear all programmed data in the controller for all 
equipment.

•  Pump 

Assign a one-speed, two-speed pump or variable-speed 
pump to the controller.

•  Color Lights 

Only available if specific lights are installed in your 
configuration. 

•  Label Aux 

Assign custom labels to auxiliary equipment, such as an 
air blower, cleaner, solar pump, etc.

•  Temp Calibrate 

Adjust temperature displayed on the User Interface up 
or down by four (4) degrees.

•  Solar Priority 

Only available if solar heating is installed in your system.  

•  Assign JVA 

Assign  Jandy Valve

®

 Actuators (JVAs) to specific AUX 

relays, as intake or return in Pool Only mode.

•  Ext. SWC Power 

Only available if a salt water chlorinator (SWC) is 
installed in your configurations.

•  Assign Hotkeys 

Only available if AquaPalm

 is installed with your 

configuration. 

•  Diagnostics 

Display software revision information and alerts for 
troubleshooting purposes.

To access the Install Settings Menu:

•  Press and hold Up/Down arrow keys at the same 

time for about 5 seconds.

12:40PM

Pool Mode 

On

Pool Heater  80°F
Aux1 Off
Aux2 Off
Settings >
Devices >

INSTALL SETTINGS

Freeze Protect  >
Units >
Language >
Clear Memory 

>

Pump >

More

INSTALL SETTINGS

Color Light 

>

Label Aux 

>

Temp Calibrate  >
Solar Priority  >
Assign JVA 

>

Assign Hotkeys  >

INSTALL SETTINGS

Diagnostics >

12:40PM

Pool Mode 

On

Pool Heater  80°F
Aux1 Off
Aux2 Off
Settings >
Devices >

INSTALL SETTINGS

Freeze Protect  >
Units >
Language >
Clear Memory 

>

Pump >

More

INSTALL SETTINGS

Color Light 

>

Label Aux 

>

Temp Calibrate  >
Solar Priority  >
Assign JVA 

>

Assign Hotkeys  >

INSTALL SETTINGS

Diagnostics >

7.1 

FREEZE PROTECT

NOTE:

 

By factory default the filter pump cir

-

cuit is freeze protected. During freeze protec-

tion, the filter pump cannot be turned off.

IMPORTANT

Freeze protection is intended to protect equipment 

and plumbing for short periods of freezing only. It does 

this by activating the filtration pump and circulating the 

water to prevent freeze inside equipment or plumbing. 

Freeze protection does 

not

 guarantee that equipment 

will not be damaged by extended periods of freezing 

temperatures or power outages. In these conditions, 

the pool and spa should be shut down completely (e.g. 

drained of water and closed for the winter) until warmer 

weather exists.

  CAUTION

Activating the spa during freezing conditions will override 

freeze protection. This means that if you are using your 

spa when freezing conditions exist, freeze protection will 

not

 circulate water to non-spa related equipment that 

you may have freeze protected (e.g. pool cleaner, booster 

pump.) Under these circumstances, the potential for 

equipment damage may exist.

Summary of Contents for JAUTP

Page 1: ...arning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or opera...

Page 2: ...s if applicable 11 Section 6 Section System Setup Programming and Testing 11 6 1 Basic Navigation 11 6 2 Set the Clock 12 6 3 Define Equipment ON OFF Schedules 12 6 4 Test the JAUTPS JAUTP 13 Section...

Page 3: ...adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the ear...

Page 4: ...for complete details WARNING People with infectious diseases should not use a spa or hot tub To avoid injury exercise care when entering or exiting the spa or hot tub Do not use drugs or alcohol befor...

Page 5: ...ng Bracket for remotely installing UI Installation Manual Owner s Manual JAUTPS Four Function Controller with removeable User Interface UI Jandy Valve Actuators 2 Water Temperature Sensor Kit Mounting...

Page 6: ...ust be followed exactly Read through the Important Safety Information section completely before beginning installation and before operating the equipment Before you begin installation make sure you ha...

Page 7: ...Section 4 HIGHVOLTAGE WIRING WARNING Potentially high voltages in the JAUTPS JAUTP controller can create dangerous electrical hazards possibly causing death serious injury or property damage Turn off...

Page 8: ...VDC output JVA Sockets 24 VAC output Intake Return Solar Spare Input Low Voltage Heater Green Terminal Bar RS485 Network Red Terminal Bar User Interface Connector Black Modular Connector 24 VAC power...

Page 9: ...equipment requiring a ground should also be bonded to the common approved bonding point There should be one bonding connection to the controller In Canada the Canadian Electrical Code CEC dictates th...

Page 10: ...LAR SENSOR IF APPLICABLE If there is a solar panel in the equipment configuration wire the solar panel temperature sensor to the 10 pin green connector The solar sensor should be installed adjacent to...

Page 11: ...manual included in the JVA packaging 3 Install intake JVA and return JVA on equipment lines according to installation instructions in the owner s manual 4 Feed intake JVA wire through the black low vo...

Page 12: ...tes flash 5 Scroll up down to display desired minutes Press Select 6 3 DEFINE EQUIPMENT ON OFF SCHEDULES MAIN SETTINGS SCHEDULES Define automatic ON and OFF times for equipment You may set a total of...

Page 13: ...f Spa Pump On Pool Heat Off Spa heat Off Solar Heat Off More 12 40PM Pool Mode On Pool Heater 80 F Spa Mode Off Spa Heater Off Settings Devices Service Mode Devices Filter Pump Off Spa Pump On Pool He...

Page 14: ...me for about 5 seconds 12 40PM Pool Mode On Pool Heater 80 F Aux1 Off Aux2 Off Settings Devices INSTALL SETTINGS Freeze Protect Units Language Clear Memory Pump More INSTALL SETTINGS Color Light Label...

Page 15: ...ZE PROTECT EQUIPMENT Filter Pump Aux1 Aux2 Aux3 FREEZE PROTECT Set Temp Equipment FREEZE PROTECT EQUIPMENT Filter Pump Aux1 Aux2 Aux3 FREEZE PROTECT Set Temp Equipment 7 2 UNITS INSTALL SETTINGS UNITS...

Page 16: ...2 Speed VSP VSP Setup INSTALL SETTINGS Freeze Protect Units Language Clear Memory Pump More VSP SETUP Model Assign Speeds Prime Min Max Freeze VSP SETUP Model Assign Speeds Prime Min Max Freeze SET P...

Page 17: ...ty Assign JVA LABEL AUX Aux1 Aux2 Aux3 Label Aux2 Default Aerator Air Blower Backwash Chlorinator More Label Aux2 Swim Jet Valve s Wtr Feature Waterfalls Whirlpool More More INSTALL SETTINGS Color Lig...

Page 18: ...xiliary on the JAUTPS JAUTP controller so that when you select this auxiliary the valve turns Assigning JVAs lets the pool owner control certain features like diverting water to a waterfall or bank of...

Page 19: ...CES AQP 100 FFC 100 iAL 100 SWC 100 VSP 100 DIAGNOSTICS Revisions Alerts RS 485 Devices More INSTALL SETTINGS Diagnostics RS 485 DEVICES AQP 100 FFC 100 iAL 100 SWC 100 VSP 100 REVISIONS UI 1 3 Bootlo...

Page 20: ...es that all equipment is turned off until system is manually turned to Auto by service technician Timeout Indicates that all equipment will remain turned off for three 3 hours and then resume running...

Page 21: ...Heat Enabled Set to 102 F Boost OFF ON Low OFF ON Chlor Output Clock Schedules All Off Set Clock Friday 8 12 AM PM Filter Pump Spa Clner Sp3 Spillover Pool Heat Spa Heat Solar Heat AUX 1 AUX 2 AUX 3 o...

Page 22: ...t Negative Edge Not used Other 1 Other 2 Other 3 Pond Regulations Slide Solar Pump Spa Speed High Speed1 Speed2 Speed3 Speed4 Speed5 Speed6 Speed7 Speed8 Spillover Sprinkler 1 Sprinkler 2 Sprinkler 3...

Page 23: ...Clock Schedules All Off Set Clock Friday 8 12 AM PM Filter Pump Speed 2 Clner Sp3 Sp4 Temp 1 Temp 2 Solar Heat AUX 1 AUX 2 AUX 3 only shown if installed Pool 20 Spa Low 10 equipment name No Schedules...

Page 24: ...used Other 1 Other 2 Other 3 Pond Regulations Slide Solar Pump Spa Speed High Speed1 Speed2 Speed3 Speed4 Speed5 Speed6 Speed7 Speed8 Sprinkler 1 Sprinkler 2 Sprinkler 3 Vanishing Edge Swim Jet Valve...

Page 25: ...hen activated does not allow the function to work Section 11 GLOSSARIES 11 1 GLOSSARY OF SAFETY DELAYS AND LOCKOUTS Lockouts Any device can be locked out This will prevent the locked out device from b...

Page 26: ...PEN the heater will not fire If message AIR TEMP OPEN is displayed freeze protection will not operate correctly POOL HEATER ENABLED This message indicates that the pool heater is ready to use but is n...

Page 27: ...gh it preventing equipment damage TIMEOUT MODE TIME OUT mode is used by the pool service person to aid them in servicing the pool The JAUTPS JAUTP user interface will not be functional for three 3 hou...

Page 28: ...er brands product names company names trade names and trademarks used are the property of their respective owners Jacuzzi may add to change or remove any part of these materials at any time without no...

Reviews: