background image

Comfort PLUS Whirlpool Bath

Page 4 

www.jacuzzi.com

 

Installation and Operation

English

Safety Instructions

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS.

 

WARNING:   RISK OF ACCIDENTAL INJURY OR DROWNING! 

 

 

   Do not permit children to use this unit unless they are closely 

 

 

   supervised at all times. Do not use hydromassage bathtubs unless  

 

 

   all suction guards are installed to prevent body and hair 

 

 

   entrapment. Never operate the hydromassage bath if the suction  

 

 

   cover is broken, damaged or missing

 DANGER:   RISK OF SEVERE INJURY FROM ELECTRIC SHOCK OR DEATH 

 

 

 FROM ELECTROCUTION!   

 

 

 

 This unit must be connected only to a supply circuit that is  

 

 

 protected by a 15 amp ground fault circuit interrupter (GFCI). Such a  

 

 

 GFCI should be provided by the installer and should be tested on a  

 

 

 routine basis. Follow the manufacturer’s instructions when testing  

 

 

 the GFCI. The GFCI should interrupt power. Push the reset button.  

 

 

 Power should be restored. If the GFCI fails to operate in this manner,  

 

 

 the GFCI is defective. If the GFCI interrupts power to the bathtub  

 

 

 without the test button being pushed, a ground current is flowing,  

 

 

 indicating a possibility of an electric shock. Do not use this  

 

 

 hydromassage bathtub. Disconnect the hydromassage bathtub and  

 

 

 have the problem corrected by a qualified service representative 

 

 

 before using.

 WARNING:   RISK OF ELECTRIC SHOCK!

 

 

   Do not permit electrical appliances (such as a hair dryer, lamp,  

 

 

   telephone, radio or television) within 60” (1524mm) of this  

 

 

   hydromassage bathtub. Connect only to a circuit protected by a  

 

 

   ground fault circuit interrupter (GFCI). (For permanently connected  

 

 

   units) A green colored terminal (or a wire connector) marked “G,”  

 

 

   “GR,” “GROUND,” or “GROUNDING”) is provided within the  

 

 

   terminal compartment. To reduce the risk of electric shock, connect  

 

 

   the terminal or connector to the grounding terminal of your electric  

 

 

   service or supply panel with a conductor equivalent in size to the  

 

 

   circuit conductors supplying the equipment.

 

CAUTION: When using this unit, basic precautions should always be performed,

 

 

including the following:

• 

READ AND FOLLOW ALL  

  INSTRUCTIONS. SAVE THESE  

  INSTRUCTIONS.

 

• 

Use this unit only for its intended use as described in this manual.  

  Do not use attachments not recommended by the manufacturer.

• 

Never drop or insert any object into any opening.

This is a professional grade product. A knowledge of construction techniques, 

plumbing and electrical installation according to codes are required for proper 

installation and user satisfaction. We recommend that a licensed contractor perform 

the installation of all Jacuzzi® Luxury Bath products. Our warranty does not cover 

improper installation related problems.

Summary of Contents for HE96000

Page 1: ...INSTALLATION AND OPERATION INSTRUCTIONS HE96000 Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino CA 91710 1 800 288 4002 www jacuzzi com COMFORT PLUS WHIRLPOOL BATH SERIES...

Page 2: ...Comfort PLUS Whirlpool Bath Page 2 www jacuzzi com Installation and Operation English...

Page 3: ...l and keep for future reference Contents 3 Product Information 3 Safety Instructions 4 Operational Safety Instructions 6 Inspection and Testing 8 Framing and Support 8 Electrical Connections 9 Drop in...

Page 4: ...romassage bathtub and have the problem corrected by a qualified service representative before using WARNING Risk of electric shock Do not permit electrical appliances such as a hair dryer lamp telepho...

Page 5: ...cal equipment basic safety precautions should always be followed including the following WARNING RISK OF ACCIDENTAL INJURY OR DROWNING Children should not use hydromassage bathtub without adult superv...

Page 6: ...ecognize the need to exit the bath C Unawareness of impending hazard D Fetal damage in pregnant women E Physical inability to exit the bath F Unconsciousness resulting in danger of drowning Warning Ri...

Page 7: ...maged or missing WARNING Water temperature in excess of 104 F 40 C may be injurious to your health Check and adjust water temperature before use CAUTION Test the ground fault circuit interrupter prote...

Page 8: ...good order to the carrier 3 Refer any claims for damage to the carrier For definitions of warranty coverage and limitations refer to the published warranty information packed with the product or in t...

Page 9: ...be followed Always follow local building and electrical codes Grounding is required The unit should be installed and grounded by a qualified electrician Two separate GFCI protected circuits are requi...

Page 10: ...t comes fully assembled Risk of electric shock Before servicing these connections disconnect all power supply cables to both 120VAC services J2 Control Panel Schematic Diagram CANADIAN MODELS ONLY The...

Page 11: ...or drain overflow systems Nor is it responsible for damage to the bathtub which may occur during installation A non flammable protective barrier must be placed between the soldering work and the batht...

Page 12: ...uctions that are included with the kit If the bathtub is equipped with an integrated flange skip this step 4 Turn off the power supply to the GFCI protected circuit 5 Insulation may be placed within t...

Page 13: ...insure the components are not damaged or disconnected 5 Align the bathtub and connect the drain 6 Insulation may be placed within the bathtub surround Provide adequate ventilation around the motor pum...

Page 14: ...dry sandpaper You can restore the glossy finish to the acrylic surface of the bathtub with a special compound Meguiar s 10 Mirror Glaze If that is not available use automotive rubbing compound follow...

Page 15: ...e directionally adjusted To change the direction of the water flow swivel the jet nozzle to the desired angle The jets can be directed individually toward any location on your body to provide a hydrom...

Page 16: ...Jacuzzi Luxury Bath product Minor scratches which do not penetrate the color finish can be removed by lightly sanding with 600 grit wet dry sandpaper Restore the gloss using Meguiar s Mirror Glaze or...

Page 17: ...r may be clogged Open jets by rotating counter clockwise With the motor turned OFF remove the suction cover strainer and remove any debris Replace the suction cover before operating Overtightened O ri...

Page 18: ...LUS LH RH LUXURA PLUS with Integral Skirt LH RH CETRA 536 PLUS LH rh NOVA 5 PLUS LH RH MITO 6 PLUS LH RH NOVA 6 PLUS LH RH SIGNA 5 PLUS LH RH SIGNA 6 PLUS LH RH Min 54 U S gal 204 liters Max 72 U S ga...

Page 19: ...KIT 62 1575 mm L 43 1092 mm W 19 483 mm H 779 lb 354 kg 44 2 lb ft2 215 kg m2 Min 40 U S gal 151 liters Max 58 U S gal 220 liters 96 lb 44 kg 14 375 mm A 9 241 mm B Template Provided P N P186000 Not A...

Page 20: ...000 HEATER KIT 60 1524 mm L 60 1524 mm L 20 527 mm H 1160 lb 527 kg 46 4 lb ft2 226 kg m2 Min 61 U S gal 231 liters Max 87 U S gal 329 liters 135 lb 61 kg TARA PLUS WITH INTEGRAL SKIRT rh 16 406 mm A...

Page 21: ...tub AMIGA PLUS Right Hand 72 18 36 2 16 x 4 14 Heater Motor 12 H x 18 L Service Access Opt Service Access AMIGA PLUS Right Hand LFM 72 18 36 2 16 x 4 14 Left front motor right hand tub Heater Motor 12...

Page 22: ...nd 60 21 42 11 x 4 Motor 12 H x 18 L Service Access Opt Service Access 2 8 1 2 5 3 8 Heater MITO 5 PLUS Right Hand 30 42 60 10 x 4 2 11 7 8 Motor 12 H x 18 L Service Access Opt Service Access 5 3 8 He...

Page 23: ...2 H x 18 L Service Access 62 21 1 2 2 43 12 x 4 9 1 2 GALLERY 5 PLUS Left Hand 5 Motor 12 H x 18 L Service Access Heater 72 21 42 2 14 x 4 11 1 2 GALLERY 6 PLUS Left Hand Motor 12 H x 18 L Service Acc...

Page 24: ...CAPELLA 60 PLUS Left Hand CUTOUT CAPELLA 60 PLUS Right Hand CUTOUT Motor Heater 25 5 8 45 3 7 25 5 8 58 58 Drain Cutout 651 mm 1162 mm 1473 mm 651 mm Ref 59 1 8 1473 mm 1502 mm CAPELLA 60 PLUS with In...

Page 25: ...d Pump Motor 35 44 60 60 46 27 1 4 35 14 x 4 27 1 4 Ref 61 5 8 2 x 4 Stud TARA PLUS Right Hand Heater Motor Service Access Opt Service Access 25 1 2 648 mm 58 1473 mm 45 9 16 1157 mm 58 1473 mm 25 1 2...

Page 26: ...with operation or maintenance related questions please call our Service Support Department at 1 800 288 4002 Visit our web site at http www jacuzzi com for products services and an online copy of the...

Page 27: ...rom without limitation any of the following careless handling lifting unit by plumbing abrading finish etc including its own negligence modification of any type for any reason including modification t...

Page 28: ...replacement parts for the Options and Accessories Any replacement parts shall be covered by the original equipment manufacturer The Distributor or Dealer is responsible for knowing local code requirem...

Reviews: