background image

ENGLISH

ROUGHING-IN REFERENCE 

(RECTANGULAR)

NOTE: Some of these units have been provided with cutout templates included in shipping carton.
See CUTOUT information for each model on page 6-7.

9

Jacuzzi Whirlpool Bath   DE99000A    3/06

ROUGHING-IN REFERENCE

NOTE:

1.

Unless otherwise specified, units are produced with left or right-hand versions.

2.

Service Access dimensions given are minimum size.

3.

Measurements inside each unit represent cutout in floor to allow for drain/overflow.

4.

All measurements are in inches.  To convert to millimeters, multiply inches by 25.4.

5.

THE OVERALL DIMENSIONS ARE NOMINAL WITH A TOLERANCE OF +0 AND -1/4" (6,4 mm).

FUZION 7260 SINGLE MOTOR UNDERMOUNT 

LEFT HAND MOTOR

Motor

Heater (S)

72"

60"

36"

24.19"

12"

8.47"

18-1/2" x 4"

12" H x 18" L

Service Access

Motor

Heater (S)

72"

60"

36"

24.19"

12"

8.47"

18-1/2" x 4"

12" H x 18" L
Service Access

Optional 

Service Access

FUZION 7260 SINGLE MOTOR UNDERMOUNT 

RIGHT HAND MOTOR

FUZION 7260 SINGLE MOTOR WITH WOOD FRAME 

LEFT HAND MOTOR

72"

60"

36"

24.19"

12"

8.47"

18-1/2" x 4"

Motor

Heater (S)

12" H x 18" L

Service Access

Motor

Heater (S)

72"

60"

36"

24.19"

12"

8.47"

18-1/2" x 4"

12" H x 18" L
Service Access

Optional 

Service Access

FUZION 7260 SINGLE MOTOR WITH WOOD FRAME 

RIGHT HAND MOTOR

Summary of Contents for Fuzion 7260

Page 1: ...egistration card provided with your unit Write and save the model and serial number of your unit below Date Purchased ____________________________________________________________ Purchased From ______...

Page 2: ...G INDICATING A POSSIBILITY OF AN ELECTRIC SHOCK DO NOT USE THIS UNIT DISCONNECT THE UNIT AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRE SENTATIVE BEFORE USING WARNING FOR PERMANENTLY CONN...

Page 3: ...O THE HEAD WARNING RISK OF ELECTRICAL SHOCK DO NOT PERMIT ELECTRICAL APPLIANCES SUCH AS HAIR DRYER LAMP TELEPHONE RADIOORTELEVISION WITHIN60 1 5m OFTHISHYDROMASSAGEBATHTUB WARNING RISK OF ACCIDENTAL I...

Page 4: ...___________________________ 17 Clean up After Installation _______________________________________________________________ 17 Wood Finish ______________________________________________________________...

Page 5: ...in the back of this manual All bath units are factory tested for proper operation and watertight connections prior to shipping NOTE Prior to installation the bath must be filled with water and operat...

Page 6: ...alled BN60000 Heater Factory Installed BN60000 Heater FUZION 7260 WITH TEAK SINGLE MOTOR LH RH 72 1829 mm L 60 1524 mm W 22 3 4 578 mm H 16 3 4 425 mm A 12 1 16 306 mm B 274 lb 125 kg Factory Installe...

Page 7: ...11 SPECIFICATIONS Corner Heater Motor L H W 159 mm 6 1 4 SIDE VIEW END VIEW FUZION 6666 WITH WOOD FRAME Heater Motor L H W 127 mm 5 SIDE VIEW END VIEW FUZION 6666 UNDERMOUNT DRAIN OVERFLOW B A B A Und...

Page 8: ...Access Opt Service Access 17 11 16 2 7 10 1 4 12 x 4 Heater S 70 11 16 35 3 8 70 11 16 Motor 12 H x 18 L Service Access Opt Service Access 35 3 8 17 11 16 2 7 10 1 4 12 x 4 Heater S FUZION 7236 RIGHT...

Page 9: ...hes To convert to millimeters multiply inches by 25 4 5 THE OVERALL DIMENSIONS ARE NOMINAL WITH A TOLERANCE OF 0 AND 1 4 6 4 mm FUZION 7260 SINGLE MOTOR UNDERMOUNT LEFT HAND MOTOR Motor Heater S 72 60...

Page 10: ...represent cutout in floor to allow for drain overflow 4 All measurements are in inches To convert to millimeters multiply inches by 25 4 5 THE OVERALL DIMENSIONS ARE NOMINAL WITH A TOLERANCE OF 0 AND...

Page 11: ...0 AND 1 4 6 4 mm Motor 12 H x 18 L Service Access Heater S 46 61 66 20 X 4 32 97 Ref 66 37 23 9 29 32 97 40 94 40 94 69 68 FUZION 6666 CORNER WITH WOOD FRAME LEFT HAND MOTOR Motor 12 H x 18 L Service...

Page 12: ...hould be level to each other NOTE Drop In Bath units are equipped with metal anchor straps These straps can be used to secure the unit to the floor or sub floor to reduce movement after installation I...

Page 13: ...TAR MORTAR MUST BE IN CONTACT WITH ALL FOAM FEET With bath and template in this position using a grease pencil mark on the bath the center line positions through the cut out Remove template Measure fr...

Page 14: ...bath rim If maintenance or remodelling is required the counter may have to be removed Adhesive will permanently bond the counter to the bath This will make removal difficult and costly and may cause...

Page 15: ...tice is not commonly implemented it is an acceptable method In some cases access may have been provided in Area A but service is required in Area B which requires the unit to be pulled for service and...

Page 16: ...e 120 VAC 20 AMP pump motor or control box power cord ONLY to the 120 VAC 20 AMP GFCI circuit Connect the 120 VAC 15 AMP heater power cord ONLY to the 120 VAC 15 AMP GFCI circuit FOR 230 VAC units Con...

Page 17: ...ate the acrylic surface will require refinishing Ask your Jacuzzi Whirlpool Bath dealer for special instructions or visit our web site at http www jacuzzi com To find service agent listings for Electr...

Page 18: ...cular motion around the bath causing a total whirlpool effect Water Force The high volume fully adjustable jets can be adjusted to control the force of the water coming into the bath For robust action...

Page 19: ...om no air to maximum air Left Air Valve Status LED The Left Air Valve Status LED will show four LED lights at maximum air and only one LED light when the air is turned OFF Each additional LED indicate...

Page 20: ...heater includes an exclusive High Limit switch This safety circuit will not false trip from hot tap water It will only turn off the heater if the thermostat fails To reset press the button If the high...

Page 21: ...irlpool bath be purged at least twice a month For best results however we recommend that you purge your whirlpool bath after each use using our exclusive two part plumbing system cleaner made specific...

Page 22: ...ways be in place on the suction fitting to mini mize the potential hazard of hair and body entrapment NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSEMBLY Chromotherapy Li...

Page 23: ...e properly connected Replace Control Panel and or Control Box Open jets by rotate counterclockwise With motor turned off remove safety cover and remove any debris Re place suction cover before operat...

Page 24: ...label is located on the wall of the bath near the pump motor Non jetted baths The label is located next to the overflow MODEL XXXXXXX NAME XXXXX COLOR XXXXX MFG XXXXX SER XXXXXX MADE IN USA THIS PRODU...

Page 25: ...ch as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss...

Page 26: ...rum Dr Suite 400 Dallas TX 75254 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company...

Reviews: