72
total number of Turkish baths already performed is not reset/
reduced (see scale-removal cycle).
X
(AL6) Filling solenoid valve and/or level sensor fault.
This may occur during the initial phase of the Turkish bath or
during the function. The cause may be a blocked sensor, an
obstructed filling solenoid valve or lack of water.
It may also occur during the final draining phase of the scale
removal cycle.
TOP model:
he display shows
AL6
.
The function (Turkish bath
or scale-removal cycle) is interrupted. and the total number of
Turkish baths already performed is not reset/reduced (see scale-
removal cycle).
AL6
TT model:
the “alarm” and “Turkish bath” keys remain on (white
light) and the second LED from the top will flash.
The function
(Turkish bath or scale-removal cycle) is interrupted. and the
total number of Turkish baths already performed is not reset/
reduced (see scale-removal cycle).
X
(AL7) Temperature not reached in the shower unit.
This may occur during the Turkish bath, due to a faulty heating
element. Or, if the initial temperature is lower than 25 °C and the
function is active for 5 minutes, the probe does not measure a tem-
perature increase of at least 5 °C (e.g. the shower unit door is open).
TOP model only:
the display shows
AL7
for a few seconds and
the function ends normally.
AL7
X
(AL13) Activation of the safety thermostat.
This may occur during the Turkish bath.
TOP model:
the display will show
AL13
for a few seconds and
it will not be possible to start the function; if instead the alarm
appears when the function is in progress, it will be interrupted .
AL13
TT model:
the “alarm” key remains on (white light) and the
"Turkish bath" key will flash; it will not be possible to start the
function. If instead the alarm appears when the function is in
progress, it will be interrupted.
X
(AL14) Error accessing the card where the audio data is
stored.
This may occur when playing, copying or deleting an audio
file.
TOP model only:
the display will show
AL14
for a few seconds
and it will not be possible to use the MP3 player .
If instead the alarm appears when the function is in progress, it
will be interrupted.
AL14
X
(AL15) Radio malfunction.
This may occur due to failed communication between the
control panel and the system.
TOP model only:
the display will show
AL15
for a few seconds
and it will not be possible to use the radio.
If instead the alarm appears when the function is in progress, it
will be interrupted.