background image

Section 1c 

– GENERAL PRODUCT INFORMATION 

RMATION 

  

Table of Contents

Table of Contents 

COMMANDER II

 

MODEL JC5

 

  

  

 

 

Section 1 

GENERAL INFORMATION 

1a 

Product Information and Contact Numbers.....................................................................................1 

1b 

Important Safety Instructions..........................................................................................................2

 

1c Table 

of 

Contents ............................................................................................................................3 

 

Section 2 

INSTALLATION   

2a Main 

Components ...........................................................................................................................4 

 Specifications 
2b Control 

Box 

Connections................................................................................................................5 

  

Electrical 

Connections 

 

 

Cell Cord and Tri-Sensor Connections 

  

ORP 

Connections 

2c Cell 

and 

Manifold Installation.........................................................................................................6 

 

Verification of Flow Switch Protection ..........................................................................................6 

 

Section 3 

OPERATION 

3a 

Key Features – Control Panel..........................................................................................................7 

3b Pool 

Water 

Preparation ...................................................................................................................8 

  

Salt 

Requirement 

Chart 

 Start-Up 

Procedures ........................................................................................................................8 

3c 

Monitoring and Maintenance ..........................................................................................................9 

 

 

Water Chemistry Parameters 

  

Saturation 

Index 

 

Section 4 

SERVICE and MAINTENANCE 

4a Servicing .........................................................................................................................................10 
 

 

Control Box  

  

Tri-Sensor 

4b Servicing .........................................................................................................................................11 
  

Cell 

Removal 

 

 

Cell Maintenance and Cleaning 

  

Filter Backwashing..........................................................................................................................11 

4c Parts 

Explosion ...............................................................................................................................12 

 

Section 5 TROUBLESHOOTING 

5a Troubleshooting ..............................................................................................................................13 

 

Appendix

 

Diagnostics......................................................................................................................................14 

 
 

3

Summary of Contents for COMMANDER II JC5

Page 1: ...S ACT This cell must only be used on this model of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device COMMANDER II Model JC5 before u...

Page 2: ...in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Competition Inc 12775 rue Brault Mirabel Qu bec Canada J7J 0C4 Tel 450 437 2420 REGISTRATION NO 2784...

Page 3: ...ing Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This pest control product is to...

Page 4: ...Unit Model Number Commander II Serial Number ____________________________ Cell Model Number JC5 Serial Number ____________________________ Factory Direct Customer Assistance HOTLINE 1 450 437 2420 FA...

Page 5: ...n Canada 5 WARNING Maintain water chemistry in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supe...

Page 6: ...ri Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt...

Page 7: ...page 10 for Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to t...

Page 8: ...agram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth...

Page 9: ...erify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or eq...

Page 10: ...water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on N...

Page 11: ...tain a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the...

Page 12: ...dium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name a...

Page 13: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel...

Page 14: ...a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner...

Page 15: ...d ordered separately Red Cap Plug for JC5 cell cord 19050 3 6m 12 ft Cell Cord 952 1 Union O Ring 19013 Cell JC5 Nut Half only 2 pc for 50 mm 2 in S x S Union Thread Half Only for 50 mm 2 in S x S Uni...

Page 16: ...Cell B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive...

Page 17: ...the case of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The s...

Page 18: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...