![background image](http://html1.mh-extra.com/html/jacto/hd-series/hd-series_operators-manual_3190633012.webp)
12/68
5.1. Troubleshooting
•
Put about 2 liters of water in the tank.
•
While operating the lever, look into the tank to see how the
problem arises.
•
Refer to the table and diagram below.
4.8. Disposal of waste products
The elimination of waste resulting from the dismantling of
equipment during service, maintenance or end of life (disposal)
should be carried out respecting the environment, preventing
pollution of air, soil and water. If necessary, the waste should be
stored in appropriate locations and then transported by quali-
fied and trained people and companies.
Disposal of used spray should be done at appropriate points and
approved for receiving such material. If there isn’t an appropri-
ate nearby site, please contact the Customer attendance: Dr. Luiz
Miranda, 1650, 175780-000 – Pompeia – SP – Brazil. Phone: +55
14 3405 2113. Email: [email protected]
Opening Hours: Monday to Friday 7:00am to 11:30am and
13:00pm to 17:18pm (Brazilian time zone).
5. Information Needed by User
DESCRIPTION
CAUSES
CORRECTIONS
Leakage through the cylinder upper part.
Worn or dried out
piston cup.
Replace or lubricate
the pump.
After pumping and
pressurizing the chamber, as you operate the
lever it drops fast.
Cylinder valve
not sealing properly
due to wear or impurities.
Clean or replace
the valve.
After pumping and
pressurizing the chamber, the lever rises
quickly when released.
Chamber valve
not sealing properly
due to wear or impurities.
Clean or replace
the valve.