TROUBLESHOOTING 9
27
9
TROUBLESHOOTING
9.1 GENERAL ________________________________________________________________
The troubleshooting chart below lists basic problems that may occur during start-up and operation. For more detailed
information, contact your area Jacobsen Dealer.
Symptoms
Possible Causes
Action
Unit does not have
1.
Power Connector Disconnected
1.
Connect Power Connector
power
2.
Batteries Discharged
2.
Fully charge battery pack
3.
50 Amp fuse blown
3.
Open battery tray and check fuse. Replace
4.
3 Amp fuse blown
4.
Check fuse, Replace
5.
Defective Battery
5.
Perform load test, replace batteries as needed
6.
OPC bail engaged
6.
Disengage bail and restart
7.
OPC Switch out of adjustment
7.
Adjust OPC Switch
Mower does not
react to O.P.C.
Lever
1.
Power switch not on
1.
Follow proper start-up procedure
2.
Parking brake engaged
2.
Disengage parking brake
3.
Reel switch in off position
3.
Turn reel switch on
4.
Broken Belt
4.
Check and replace belts as needed
5.
OPC Switch out of adjustment
5.
Adjust OPC Switch
Reel does not cut,
or cuts unevenly
1.
Reel to bedknife not adjusted
1.
Adjust Reel to Bedknife
2.
Reel switch in off position
2.
Turn reel switch on