12-2015 H0522EN00
65
EvENT
HIsTory
This function allows to view and filter the events recorded from
the equipment by:
-All events
-Access to the programming menus.
-Changing parameters
-Cleaning
Touch the “Delete” button to delete the displayed events.
fAuLTs
Displays the machine faults.
If there are no faults the list is empty
P
umP
fAuLT
1...7
If the current absorption of a pump is not between the range of
default values, all the selections in which the pump is involved
are disabled.
f
AuLTy
mIxEr
1...6 (
wHIPPEr
fAuLT
)
If the current absorption of a mixer motor is not between the
range of default values, all the selections in which that mixer is
involved are disabled.
soLENoID
vALvE
1...7 (
vALvE
fAuLT
)
If the current absorption of a solenoid valve is not between the
range of established values, all the selections in which that
solenoid valve is involved are disabled.
s
HorT
CIrCuIT
mosfET
The machine fails if a device intended to control direct current
motors on the actuation board (mosfet) remains active.
s
HorT
CIrCuIT
This failure is displayed if the software should detect a short-
circuit on one of the direct current motors connected with the
actuation board. A failure may be simultaneously detected on
one of the direct current motors.