Page 1: ...H0522EN00 05 2016 9100 IN OPERATOR MANUAL Original instructions Translation of the original instructions EN English ...

Page 2: ... this manual without notice Published by N W GLOBAL VENDING GROUP Via Roma 24 24030 Valbrembo BG Italy Published in 2016 week 22 The symbol indicates that the machine may not be disposed of as ordinary waste it must be disposed of in accordance with the provisions of the European directive 2002 96 CE Waste Electrical and Electronics Equipments WEEE and of any resulting na tional laws for preventin...

Page 3: ...nce routines 14 weekly 16 deep cleanings 20 Preventive maintenance 25 activation board 35 touch screen CPU board 37 power supply board 39 boiler control board 40 electrical diagrams 42 hydraulic circuit 47 hydraulic circuit 49 hydraulic circuit 51 Access to the programming menus 52 entering the values 55 daily actions 57 selection settings 58 MACHINE SETTINGS 67 machine information 75 energy savin...

Page 4: ...2 12 2015 H0522EN00 ...

Page 5: ...g All parts of action are supplied in a green colour If the vending machine is not used ac cording to its purpose the manufacturer cannot take on any liability This operator manual is valid for several variants of the vending machine The refore it is possible that in this operator manual you may find instructions for operating elements that are not installed in your vending machine This technical ...

Page 6: ...ed and repaired by qualified personnel who are trained in the correct use of the machine according to the standards in force and who have the specific knowledge of the machine functioning from a point of view of electrical safety and health regulations Safety devices must not be bridged or put out of function The vending machine must be con nected to the drinking water line and to the electric lin...

Page 7: ...his plate is the only one acknowledged by the manufacturer as identification of the machine The technical data of the vending machine are given on the rating plate When the yellow special key is inserted in the slot of the door switch the voltage is re established to the machine The door can be closed only after removing the key from the door switch If power is turned on be careful not to touch mo...

Page 8: ...n Water system connec tion The vending machine must be connected with the potable water system according to the provisions in force in the place of installation of the equipment Min back pressure Max pressure without chiller 0 8 bar 0 08 MPa 8 5 bar 0 85 MPa Hose connection Connect the water network with the 3 4 gas union of the water inlet solenoid valve by means of a tube that can support the ne...

Page 9: ...nation G9 and Vender is not to be operated without credit mechanisms Check for adequate space for correct ventilation A distance of 55 mm is required from the rear side of the machine to the wall Check for clear space of 525 mm in front of the machine to allow the door to be opened Ensure that the supply voltage corresponds to the voltage indicated on the rating plate which is located on the rear ...

Page 10: ...8 12 2015 H0522EN00 PRODUCT PRESENTATION EXTERNAL CABINET 1 2 3 4 6 7 5 Fig 1 1 Cabinet 2 Door 3 Touch screen panel 4 Advertising poster 5 Door lock 6 Cup holder drip tray 7 Pot platform ...

Page 11: ...active gestures are required tap Tap icons features and objects to activate or open contextual menus move drag To move drag icons and objects touch and move drag to another location scroll Slide the finger on the touch screen to the right left up or down to scroll through the values screens and functions ...

Page 12: ...cons In normal operation the machine displays the screen with the available selections In the event that an anomaly is detected by the control elec tronics a message will be displayed indicating the type of fault error Some selections may be disabled with some types of failures for example empty powder containers Fig 2 1 Access to the status panel 2 Date and time display area 3 Available credit di...

Page 13: ...n 6 Beverage nutritional information 7 Cancel beverage button 8 Beverage price if applicable Therefore to beverage in the cup Place the cup under the nozzles Customize the beverage according to your taste Touch the Dispense button The beverage is dispensed fill a jug Place the pitcher under the nozzles Customize the beverage according to your taste Touch the Jug button Touch the Dispense button Th...

Page 14: ...ation 2 Entertainment content area 3 Entertainment icons 4 Stop button MACHINE STATUS You can view the status of the machine eg residue containers level containers level using the status panel To open the status panel touch the top of the touch screen and drag down The status panel displays the status of trays and containers Text or symbol in green color if there aren t alarms Text or symbol in re...

Page 15: ...E CABINET 2 3 4 5 6 7 8 9 Fig 5 1 Outlet spout 2 Mixing funnel with whipper housing 3 Mixing funnel hood 4 Cash box option 5 Retaining pin for cup carrier 6 Drip tray 7 Heating element cover 8 Nozzle 9 Instant ingredient canister ...

Page 16: ... the machine Removing the waste containers Filling the instant ingredient canisters Filling the coffee bean canister Cleaning the cup carrier Cleaning the drip tray Cleaning the machine interior and exte rior Mounting the cleaned parts Rinsing machine Last check 1 bucket of hot water 60 80 C with cleaning agent 1 bucket of clean warm min 40 C water Soft clean cloths or paper towels Ingredients ...

Page 17: ...12 2015 H0522EN00 15 Interval Type of work Check Exchange kit hygiene kit Occasional Once a month Cleaning the instant ingredient canisters Cleaning the coffee bean canister ...

Page 18: ...ectrical components Fig 7 Preparing for filling of canisters Remove lower drip tray and the upper plate clean the parts with a sprayed wipe Fig 8 Remove waste bucket and lower plate empty coffee waste Clean all the remo ved parts and the base of the machine with a sprayed wipe Ensure that the sensors in the liquid container are not covered by the plastic liner in solid waste container ...

Page 19: ... 17 Fig 9 Reset drip tray counter Tap Empty solid waste Fig 10 Filling the instant ingredient canisters Remove sugar caniste optional turn it up pull it outward Put it on a talble Fig 11 Pull up instant canister outlets ...

Page 20: ...ers Fig 12 Put canisters on a table open lids then fill them with products Clean outside canisters before place them back into machine Repeat procedure until the required number of canisters have been filled Clean instant canister table and place canisters back Fig 13 Cleaning drip tray Unscrew the knurl that fix external drip tray clean external drip tray with a wet wipe Place it back ...

Page 21: ...CLEANINGS Clean all the other parts Remove head of mixing bowls spray into the m clean with wipe and replace the head of mixing bowls Fig 15 Remove mixing bowls and pipes exhaust system area and mixer plates Fig 16 Remove water nozzle ...

Page 22: ...s using cleaning materials finally wash with clean water Dry the parts accurately head of mixers exhaust system parts funnell for coffee powder and brewer Reassemble dried parts Be careful with proper positioning of hoses Place back all the canisters open coffee shutters Push down instant canister outlets ...

Page 23: ...nsing close the door or simulate door closing by placing the yellow key into its slot select Wittenborg then Maintenance and Daily operations Fig 20 Chose the to be rinsed then press OK Fig 21 Clean internal and external side of the door with wet wipe ...

Page 24: ...22 12 2015 H0522EN00 Fig 22 Clean the whole cabinet with wet wipe Fig 23 Fill in the HACCP documentation book Remove the yellow key close the door and start up ...

Page 25: ...er of rotations of the grinding wheels allowing the control software of the machine to determine the number of rotations and thus the grams of coffee for each single selection With the programming procedure it is possible to set the grams 6 to 15 gr of ground coffee rotations of the grinder for each selection Important Never touch the adjusting knob of the grinder Always call a technician for adju...

Page 26: ...nd the metal cover to access the com ponents of the electrical panel The fuses are accessible from the door of the electrical panel cover The electronic boards are designed to be used on several models of machines In case of replacement it will be necessary to verify the con figuration of the board and load the adequate software ...

Page 27: ...is supplied from the power supply board The board is placed in the electrical panel of the equipment and manages the activation of the various users sensors control signals level presence The LEDs indicate DL1 18 green LED DL2 30 green LED flashes during normal operation DL3 15 yellow LED that indicates the presence of 5Vdc DL4 29 yellow LED flow meter pulses DL5 28 not used DL6 33 not used DL7 32...

Page 28: ...T12 R263 R312 T31 R258 R443 C102 R51 R110 R247 T37 R514 R308 R506 R322 D37 R174 R182 C29 R336 R86 T116 R69 T34 R417 R433 C60 JP2 C55 R53 R425 R328 R400 R175 R208 R518 R280 T70 C96 J18 R157 T66 R432 C62 C89 C26 D75 C92 T94 R245 J13 C95 R347 DL3 R169 C10 R9 D23 R55 R517 R424 C11 C81 R89 R190 R273 C131 R505 R223 R395 J16 R309 C78 R132 R427 R54 R448 R205 R268 C59 R368 R341 R201 R196 RL9 D57 R396 DL2 R...

Page 29: ... BOARD Board is powered in 24 V Power is supplied from the power supply board The board is placed on the door and manages touchscreen payment systems if present mechanical stroke counter if present machine lighting cup sensors Ethernet connection Wi Fi and or Bluetooth module if present IrDA board if present The board has three LEDs for indicating The board is powered led power 24V The board is in...

Page 30: ...net connector 10 JP3 jumper 11 J28 Not used 12 J27 Cup Sensors LED lighting mechanical stroke counter 13 J31 Not used 14 JP1 closed jumper 15 Touchscreen management module 16 Wi Fi and or Bluetooth module if present 17 SIM CARD slot 18 SW2 Microswitch 19 SW1 Button 20 SD card slot 21 J11 Not used 22 J9 USB connector 23 J22 RS232 serial connector 24 Led run 25 Led reset 26 Led power 24V 27 J20 Not ...

Page 31: ...are Tap browse to open the navigation window of the USB stick file system Select the file with the software update Tap Check to check that the file is intact Tap Validate to perform a compatibility check Tap Update to update update via internet Enter the address of the FTP server with the software updates and the credentials for access to the FTP server username and password Tap Check to check tha...

Page 32: ...D Board is powered with 230 V The board provides power to the control electronics 24V and the touch screen The board is placed in the electrical panel of the equipment 1 2 J2 J1 Fig 27 1 J2 24Vdc connector 2 J1 230Vac power supply connector ...

Page 33: ...12 2015 H0522EN00 31 ...

Page 34: ...H0522EN00 BOILER CONTROL BOARD The board controls the activation and deactivation of the heating elements of the boiler J1 J2 1 2 Fig 28 1 J1 board control connector 2 J2 boiler heating element supply connector 3 ...

Page 35: ...12 2015 H0522EN00 33 Appendix ...

Page 36: ...6 X2 7 X2 8 2 1 3 2 1 3 2 1 3 2 1 3 26 OUTDEV8 EEA 62 24VPC J12 14 J12 1 9 6 92 90 IPF IPF liq WL IN J10 7 J10 8 GND 0 X10 3 X10 2 X10 1 J17 9 DIG IN15 7 J10 2 OUT ULN 3 PRR CMMR MR DIG IN23 J20 5 DIG IN19 J20 1 RENDIRES MOT P J16 4 Changegiver door GND J16 8 0 90 93 70 X1 14 X1 13 X1 12 X1 5 Sled 1 2 J6 3 12V X12 4 X12 3 X12 2 X12 1 X1 6 9 91 80 3 3 4 MD9 Z4000_MOT_P J19 5 71 2 J19 8 PGND 9 1 0 9...

Page 37: ... SWITCH IPF FULL WASTE SWITCH IPS TOP PANEL SWITCH ISER1 SLIDER COFFEE CONTAINER SENSOR IVA EMPTY WATER SWITCH KC1 COFFEE BOILER CUTOUT KS1 SAFETY CUTOUT M COFFEE UNIT MOTOR MAC1 COFFEE GRINDER MD1 INGREDIENT MOTORS MF1 INSTANT WHIPPER MOTORS MFB FRESH BREW MOTOR MMA1 GRINDING REGULATION MOTOR MR COIN RETURN MOTOR NTC TEMPERATURE PROBE PM PUMP PRR COIN RETURN BUTTON RCC COFFEE BOILER HEATING ELEME...

Page 38: ... 96 8 15 8 16 8 17 8 18 8 12 8 13 8 14 0 2 8 15 8 16 8 17 8 18 0 2 8 5 3 8 0 8 4 8 6 7 8 9 8 10 8 1 0 8 3 8 7 1 6 0 80 1 6 0 80 60 90 60 90 7 7v 2 7 9 8 4 5 1 2 1 Sled 2 1 Sled 2 1 Sled VEND JUG FREE 9100 SCHEMA ELETTRICO PORTA 9100 15 10 2013 608606400 BONACINA BORLOTTI B A3 This drawing contains confidential information and is the property of the holding company of N W or one of its subsidiaries...

Page 39: ...G GENERAL COUNTER EX EXECUTIVE COIN MECH CONNECTORS FREE FREE VEND SWITCH IRDA IRDA BOARD JUG JUG FACILITIES SWITCH MDB MDB COIN MECH CONNECTOR RS232 SERIAL PORT SALIM POWER SUPPLY UNIT BOARD SLED LED BOARD SM MACHINE BOARD SUC C P U BOARD TZ CUP SENSOR ...

Page 40: ...38 12 2015 H0522EN00 1 2 3 4 ...

Page 41: ...12 2015 H0522EN00 39 HYDRAULIC CIRCUIT IN model Fig 29 1 BOILER 2 MIXER SHELF 3 INLET VALVE 4 RE CIRCULATION VALVE ...

Page 42: ...40 12 2015 H0522EN00 1 2 3 4 5 Fig 30 HYDRAULIC CIRCUIT cabinet 1 SUCTION PUMP 2 TANK 3 LIQUID WASTE CONTAINER 4 TO THE DEVICE 5 LIQUID RESIDUE CONTAINER DRAIN PIP ...

Page 43: ...e one displayed on the machine depending on the configuration layouts themes and or icons ACCESS TO THE PROGRAMMING MENUS To access the menu of the machine with the door closed tap and hold for 3 seconds the logo at the top left of the selections screen When the door is open the machine may require a password to access the programming menu Enter the password to access the enabled menus The passwor...

Page 44: ...d Allows to search for the function by name Tap to view the keyboard Type the name of the function the functions that contain the typed text are displayed while typing From the search results displayed touch the desired function navigation side menu Shows the functions available for the current user profile and the next back buttons exit icon Exits from the programming menu without saving The sele...

Page 45: ... tap the icon in the message bar the icon will change color it is disabled keypad Use the keypad to enter the password to access the menu ac cording to the user profile User profiles enable users to access only certain specific func tions enabled for their user profile message bar Shows notification icons water level solid residues level powders level Touch the icons to get an indication on the st...

Page 46: ...last maintenance ENTERING THE VALUES The values in the programming menu can be entered modi fied as follows Keyboard 1 2 3 4 9 5 6 7 8 Fig 32 1 Enter the next uppercase character shift 2 Swap the keyboard from numbers symbols to letters 3 Swap the keyboard from letters to numbers symbols 4 Enter uppercase characters caps lock 5 Move the cursor in the text 6 Insert a new line 2 line text 7 Confirm ...

Page 47: ... last number entered back space 3 Cancel the entered values and closes the keyboard Checkbox Tap the checkbox to enable disable the option Fig 34 Drop down list Tap to open the drop down list and select the value Fig 35 Value pickers Scroll to select the desired value Fig 36 ...

Page 48: ...erly manage the containers pre alarms if enabled Fill the container with the product and indicate the amount of product loaded solid residue container Resets the counter which handles the reporting of residues full of the solid residue container To ensure the right management of the warnings you must reset the counter any time the solid residue con tainer is emptied money management Enabled only f...

Page 49: ...te and customize the beverage edit beverage From the screen you can Change the name of the beverages displayed in normal op eration Define which recipe to use for the beverage Change the selection image in normal operation Tap the image to open the screen of choice of the new image to use Create a multimedia playlist to be played during dispensing To enable disable the display of multimedia conten...

Page 50: ...ill appear on screen set the capacity of the cup used to obtain a representation indicative of the quantity of beverage in the cup If the amount of the beverage exceeds the set size of the cup an error message is displayed Set the number of dispensing cycle to fill a jug tap Add New to add the products that make up the recipe such as coffee chocolate The screens of the parameters vary depending on...

Page 51: ...he beverage exceeds the set size of the cup an error message is displayed Set the number of dispensing cycle to fill a jug add more instant products to the recipe e g chocolate milk if necessary add presets to the drink such as sugar and set the possible increase in the price of the drink To edit the settings of individual products for example amount of water powder tap the bar corresponding to th...

Page 52: ... delay of the ingredient the delay is useful if recipes composed of multiple ingredients are created For example when creating the recipe Espresso with milk a time delay between the dispensing of espresso and milk can be set It can be helpful to obtain a better presentation of the beverage Coffee cake squeezing The coffee cake is squeezed by the upper piston that helps re moving water from the cof...

Page 53: ...ce Warning This value must be greater than or equal to the squeeze down force value pre infusion dose Sets the amount of water ml to be used during the pre infu sion pre infusion time Sets the pre infusion time before the infusion current profile Set 3 pressure profiles for the espresso infusion High Medium low With Low the machine shows parameters for the infusion at low pressure see parameters f...

Page 54: ...rce Warning This value must be greater than or equal to the squeeze down force value squeeze start This parameter in of the delivery time allows to establish for how long the infusion takes place at low pressure freshbrew and how long at high pressure espresso The modification of the parameter results in the absence or the variation of the amount of cream in the beverage For example A value of 100...

Page 55: ... the upper piston in the chamber during infu sion at low pressure fresh brew Default value 430 A value close to 1023 indicates that the upper piston is very close to the lower piston Warning A value lower than the default may result in the leakage of hot water from the brewing unit pre infusion dose Sets the amount of water ml to be used during the pre infu sion pre infusion time Sets the pre infu...

Page 56: ...ed to the stopping time of the pump solenoid valve The duration of the mixing is set in milliseconds and is calcu lated from the moment of activation of the pump valve Mixing speed low medium high You can define the mixing speed according to the product qual ity you wish water queue Extends the dispensing of water in the mixer at the end of the mixing to allow adequate rinsing of the mixer Set the...

Page 57: ...a preview of the new color is displayed Calibrate the grinding of the coffee beans The calibration allows to adjust the working speed of the grinder depending on the grams ground To calibrate proceed as follows Start the calibration procedure a dose of coffee beans is ground and dropped Weigh the coffee powder Enter the detected weight Calibrate the instant beverages and pre ground coffee motor do...

Page 58: ...your settings match the actual configuration of the equipment The device adjusts the operating cycles of the functional groups according to the choices made Settings that do not meet the actual configuration can be dangerous and cause damage MACHINE SETTINGS configuration select configuration Allows to manage the configuration provided by the software of the device You can delete and duplicate con...

Page 59: ...a saved configuration file Warning Import can be used to clone settings from another ma chine ensure settings compatibility between devices export to usb Allows to export machine settings to a saved configuration file Warning Export can be used to clone current settings to another machine ensure settings compatibility between devices edit interface strings For the available languages you can chang...

Page 60: ...nction import Allows to browse and select files from a USB stick with custom graphics to be imported into the machine export Allows to save custom graphics to a USB stick display settings Enables disables the view of the following number of dispensed beverages at machine start up price of the selections in normal operation date and time screen saver enabling it allows to enter the time after which...

Page 61: ...nabled you can watch the news using an RSS feed Choose the Internet address of the RSS feeds from the default ones or enter a custom address input sensors settings The function group allows to set the operation of some of the equipment sensors containers level Enables disables the level sensors of the containers Displays the various containers with filling levels and adjustable parameters Calculat...

Page 62: ... the sensor cup enabled the machine delivers the drink only with in the Presence of the cup If you request a selection without placing the cup the machine shows message place cup Set high sensitivity for glasses cups small and semi trans parent Set low sensitivity for glasses cups large and colorful Calibrations flow meter calibration The flow meter calibration allows to obtain the correct amount ...

Page 63: ...a preview of the new color is displayed Calibrate the grinding of the coffee beans The calibration allows to adjust the working speed of the grinder depending on the grams ground To calibrate proceed as follows Start the calibration procedure a dose of coffee beans is ground and dropped Weigh the coffee powder Enter the detected weight Calibrate the instant beverages and pre ground coffee motor do...

Page 64: ...n of the infusion chamber of the infu sion unit Setting the position of infusion chambers allows the ground coffee to be arranged more homogenously in the infusion chamber fan settings Enables disables the continuous operation of the steam suc tion fan OFF the fan is activated only during the preparation of bever ages and for the next 30 seconds at the end of the prepara tion of the beverage ON th...

Page 65: ...ce alert Resets the counter which handles maintenance alerts Reset the counter only after completing all maintenance General configuration Tank The machine can be supplied by mains or internal tank With this function you can define whether the device is pow ered from the mains tank OFF from tank with water level sensor tank ON Payment system activation Enables disables the payment system of the ma...

Page 66: ...re threshold mixer anti lock Sets how long after the last selection with instant beverages the mixer is briefly turned on anti lock function This function is useful when residues of instant powder remain in the mixer MACHINE INFORMATION faults The machine has a number of sensors for keeping the various functional groups under control When an anomaly is detected the machine displays the type of fau...

Page 67: ...e current absorption of a mixer motor is not between the range of default values all the selections in which that mixer is involved are disabled solenoid valve 1 7 valve fault If the current absorption of a solenoid valve is not between the range of established values all the selections in which that solenoid valve is involved are disabled Short circuit mosfet The machine fails if a device intende...

Page 68: ...me during filling Coffee unit failures The position control microswitch of the coffee unit is read dur ing the whole dispensing cycle According to the micro readout and the dispensing phase of the unit any failure is declared by locking the selections based on espresso coffee Coffee unit micro unit failure While the brew unit is being handled the control micro is not operated within a certain time...

Page 69: ...r leak in the boiler thorough machine cleaning Reports the need to perform a thorough cleaning of the ma chine This message is displayed when the time limit or the configured number of selections are reached washing of the espresso unit with tablets Reports the need to wash the espresso unit using sanitizing tablets This message is displayed when the time limit or the configured number of selectio...

Page 70: ...reset the fault drip tray not present The liquid residue container does not operate the micro switch indicating the presence of the container Check that the liquid residue container is correctly positioned inside the machine water tank empty Lack of water from the mains or self feeding tank Make sure that the machine is connected to the water mains and that the tap is open or the tank is full of w...

Page 71: ...ower than the minimum temperature programmed to dispense espresso Wait for the minimum dispensing temperature to be reached empty doser 1 7 The minimum level of instant powder in the container associ ated with motor doser has been reached The signal is active if they controls on instant powder contain ers are activated Check the level of instant powder in the containers tea brewer It is due to a p...

Page 72: ...t on the machine it cannot be loaded or created Make sure there is sufficient memory space statistics show statistics Displays statistics on selections Displays selections statistics showing the number of dispensed selections date and time of last dispensing statistics reset Touch the Delete button to delete the selections statistics show audit Displays the total number of payments and the total d...

Page 73: ...e bar the icon will change color it is enabled delete favourites Removes all functions from the favourites machine id Allows you to enter a number and the name that identifies the machine The code can be used for the identification of the machine for the analysis of the statistics installation date Stores the current date as the date of installation Before storing the date make sure you have set t...

Page 74: ...to activate the profile set the maintenance temperature of the boiler in the energy saving phase enable disable the door light set the brightness of the touch screen normal low or off deep mode profile This profile is active on the set time frames In the set time frames the boiler temperature is lowered and the maintenance temperature is set You can set the maintenance temperature of the boiler in...

Page 75: ...time Drag the rectangle to define the exact time To delete a rectangle Tap and then touch the rectangle to be deleted You can copy the settings for each day of the week or for a single day Tap Copy day profile to Copy the time frames set for a single day of the week touch the day to set the energy saving and tap paste day profile Copy the time frames set for every day of the week tap paste day pro...

Page 76: ...oint position i e 0 decimal point disabled 1 XXX X one decimal digit after the point 2 XX XX two decimal digits after the point 3 X XXX three decimal digits after the point Booking time To set up for the cash payment how long the machine displays the residual credit necessary to dispense the selection 7 sec onds by default Line value association When the display is positioned on the LINE VALUE ASS...

Page 77: ...y default BDV Immediate change The amount relative to a selection is generally cashed after the machine has sent the Successful selection signal If you enable this function which is disabled by default the cash signal is sent at the start of the dispensing cycle The setup of this parameter is compulsory Booking time To set up for the cash payment how long the machine displays the residual credit n...

Page 78: ...fine which coins shall be accepted among those recog nised by the validator For the coin value correspondence check the label showing the position of the coins on the coin mechanism Coins accepted for change To program the refusal of a coin in case of exact amount For the coin value correspondence check the label showing the position of the coins on the coin mechanism Exact change equation To defi...

Page 79: ...ee sale function However there are some payment systems not having this function In this case it is necessary to enable the VMC vending ma chine control disabled by default free sale and to set the price of selections to zero if some selections are dispensed on a free basis MDB Immediate change The amount relative to a selection is generally cashed after the machine has sent the Successful selecti...

Page 80: ... soon as you press the change button or after one single dispensing The credit exceeding the amount you have programmed by this function will be cashed Accepted coins To define which coins shall be accepted among those recog nised by the validator when the change tubes are full For the coin value correspondence check the coin mechanism configuration Returned coins To define which coins shall be us...

Page 81: ...after a well defined time interval deleted later or to leave it at the user s disposal maintained Cash sale command The function is used to give evidence that cash transactions have occurred by means of a cashless system The values available are listed here below 0 standard operation cash transactions are recorded as such 1 forced sending to cashless 1 cash transactions are record ed as transactio...

Page 82: ... 14 A and B and C For example the 10 equation will display the No change message when all four tubes have achieved the minimum level The 04 equation will display the No change message only when tube A lower value coin has achieved the minimum level of coins Maximum cashless key credit Use this function to set up the maximum credit a cashless key card may have to be accepted by the system If the ke...

Page 83: ...s not defined User gruops The function is used to associate a price list list 1 list 2 and list 3 to the groups of users from 1 to 5 All groups of users are associated to the list by default prices Currency symbol Set up the currency symbol during the credit display Selection prices For each selection it is possible to set a price The factory settings expects the same price for all selections glob...

Page 84: ...les errors logfile Exports the errors in the machine to a log file The logfile is saved on a USB device SYSTEM components test Allows to check the main components of the machine The components that can be checked are displayed Tap the component to be tested on the touch screen infuser unit Starts the handling of the brewing unit espresso container A dose of coffee beans is ground motor dosers The ...

Page 85: ...ured by the cup sensor The function is useful for checking the sensitivity value of the cup sensor boiler filling and emptying You can fill and empty the boiler The hydraulic circuit filling is automatic In case of maintenance at the hydraulic circuit or if one were to form significant water voids perform the manual filling of the hydraulic circuit With the emptying boiler fuction is open a soleno...

Page 86: ... The equipment includes a procedure for quick cooling of the boiler The emptying function opens a solenoid valve of the boiler to allow the entry of air in the boiler machine parameters test Sets the activation time of the components during the self test Factory reset Allows to restore the device to factory settings Warning All statistical data failure list containers level control and settings ar...

Page 87: ... simply drag the flag icon to Languages disabled Fig 40 user access You can enable disable some programming functions using some access profiles Access profiles ensure that only certain functions assigned to them can be utilized Each user profile has a password The default passwords are Engineer 4444 Distributor 3333 Loader 2222 User 1111 Advanced programming functions must be reserved only for pe...

Page 88: ...he manu facturer that identifies the network card of the equipment The MAC address cannot be changed wi fi Allows to enable and configure the wi fi connection of the equipment The equipment supports leading wi fi security protocols Enter the identifier of the Wi Fi network SSID to connect to The network parameters such as IP address can be assigned automatically DHCP or manually To automatically a...

Page 89: ... device to communicate In discovery mode a wireless signal is transmitted that allows the device to be detected by other devices When a device can be detected the pairing mode is also usu ally enabled software update Shows the software version of the machine It also allows to update the machine software with a USB stick or via network connection update from usb You can update the machine software ...

Page 90: ...software via connection to an FTP server with software updates available Enter the address of the FTP server with software updates the credentials for access to the FTP server username and password information Allows to view all the information about the device software version theme used machine configuration ...